0 likes | 73 Views
Ion Chromatography is designed with a bipolar conductivity detector to improve instrument detection performance and stability. Boasts a modular design coupled with advanced <br>circuit technology. It provides a flow range spanning from 0.001 to 9.999 ml/min and has a detection range spanning from 0 to 35,000 u00b5S/cm. It is exclusively crafted for the <br>separation, identification, and quantification of ions within a sample.
E N D
Ion Chromatography www.labmate.com | info@labmate.com Overview Ion Chromatography is designed with a bipolar conductivity detector to improve instrument detection performance and stability. Boasts a modular design coupled with advanced circuit technology. It provides a flow range spanning from 0.001 to 9.999 ml/min and has a detection range spanning from 0 to 35,000 µS/cm. It is exclusively crafted for the separation, identification, and quantification of ions within a sample.
Specifications : Ion Chromatographic Type High pressure and low pulse Pump double plunger tandem advection pump Maximum 35 MPa (PEEK) pressure Pressure (0.2 to 0.5) ml/ min ≤ 3 % display accuracy (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 % Flow stability 0.001 to 9.999 ml/ min Flow range 0.001 to 9.999 ml/ min Pressure ≤ 0.5% pulse
Conductivity detector Type Temperature Control and Bipolar Conductivity Detector Detection Bipolar conductivity detection mode Cell volume ≤ 0.8 µL Detection 0 to 35000 µS/ cm range Detection ≤ 0.0020 nS/ cm resolution Output -6000 to +6000 mV voltage (adjustable) Baseline ≤ 0.05 % F.S. noise Baseline ≤ 3 % FS/ 30 min drift Operating Room temperature +5 to 60°C temperature (41 to 140°F) range
Controlling ± 0.01°C temperature accuracy Maximum 10 MPa pressure Linear range ≥ 103 Instruments ≥ 0.999 linearity Quantitative ≤ 1.0 % repeatability Qualitative ≤ 1.0 % repeatability Minimum Cl ≤ 0.0005 ug/ ml detectable concentratio BrO3 ≤ 0.001 ug/ ml n Li+ ≤ 0.001 ug/ ml
Flow system Plastic flow Made of PEEK materials path Six-way PEEK material, 5000 psi Valve pressure, independent automatic collection, and flow function Degassing Device Inner 300 µl volume Degassing 7.5 ml volume Maximum 10 ml/ min flow rate Degassing Degassing 90 % at 1ml/ min efficiency Organic 1 tolerance
Built-in Eluent Generator Eluent KOH/ NaOH types Eluent 0.1 to 100 mM concentrat ion range Concentra 0.1 mM tion increment Flow rate 0.1 to 3.0 ml/ min change Maximum 20 MPa pressure Minimum 5 MPa pressure Power supply 150 W Dimension 350 × 470 × 650 mm
Net weight 34 kg Gross weight 40 kg Features : - Featuring a gradient elution system, efficiently detects small molecules in complex samples - Incorporate temperature control for optimal analysis conditions - Includes automated components and software to streamline analysis - Built-in low-pressure degassing technology to remove bubble interference - Automated self-regenerating electrolytic microfilm suppressor - Enhanced with standard dilution function that saves time, labor, and costs - RS232 and USB interfaces Standard Accessories : Ion Chromatography host:1 High-pressure advection pump:1 Conductivity detector:1 Anion column:1 Anion guard column:1 Suppressor:1 Chromatography workstation:1 Column thermostat system:1
Spare parts kits :1 Vacuum degassing pump:1 Sand core filtration devices:1 Pretreatment column:20 0.22 µm syringe filter:200 Eluent generator:1 Optional Accessories : Autosampler (20 samples) Autosampler (54 samples) Autosampler (108 samples) Anion column Guard column Anion suppressor Spare parts kits Applications : Ion Chromatography finds application in various scientific and industrial fields such as Environmental Monitoring, Laboratories, and more. Pharmaceutical Analysis, Research Labmate Scientific Email: info@labmate.com | Website: www.labmate.com