1 / 15

Addendum to IS 449 Measurement of the isotope shift of 7,9,10,11 Be at COLLAPS

Laser. SpHERe. Addendum to IS 449 Measurement of the isotope shift of 7,9,10,11 Be at COLLAPS. The BeTINa Collaboration.

aadi
Download Presentation

Addendum to IS 449 Measurement of the isotope shift of 7,9,10,11 Be at COLLAPS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Laser SpHERe Addendum to IS 449Measurement of the isotope shift of 7,9,10,11Be at COLLAPS The BeTINa Collaboration W. Nörtershäuser1,2, K. Blaum1,2, J. Ebele4, Ch. Geppert2, M. Kowalska3, J. Krämer1, R. Neugart1, R. Sanchez1, F. Schmidt-Kaler4, D. Tiedemann1, D. Yordanov3, M. Zakova1, C. Zimmermann5 1 Johannes Gutenberg-Universität Mainz, Germany 2 GSI Darmstadt, Germany 3 CERN, CH-1211 Genéve 23, Switzerland 4 Universität Ulm, Germany 5 Eberhard-Karls Universität Tübingen, Germany Spokespersons: W. Nörtershäuser, C. Geppert Local Contacts: D. Yordanov, M. Kowalska LaserSpectroscopy of Highly Charged Ions and Exotic Radioactive Nuclei (Helmholtz Young Investigators Group) http://www.kernchemie.uni-mainz.de/laser/

  2. Radii of Halo Isotopes Charge radius measurements of light (Z<18) radioactive isotopes: 2003 : 6,7,8,9Li at GSI G.Ewald et al., PRL 93, 113002 (2004) 2004: 6He at Argonne, L.-B. Wang et al. PRL 93, 142501 (2004) 2004: 11Li at TRIUMF, R. Sanchez et al., PRL 96, 033002 (2006) 2007: 8He at GANIL, P. Müller et al. PRL 99, 252501 (2007)

  3. 2Z Isotop 1 D|(0)|2 d r2 Field Shift 3 Isotop 2 He, Li, Be : 10 GHz 0.001 GHz Isotope Shift = Frequency difference in an electronic transition between two isotopes DnIS = DnMS + DnFS Mass Effect, nuclear motion finite size of the nucleus

  4. 2Z D|(0)|2 3 2Z D|(0)|2 3 EXPERIMENT THEORY - Charge Radius : = C Charge Radii Determination for Light Elements DnIS = DnMS + DnFS

  5. Level Scheme and Be+ Transitions

  6. 11Be+ F=0 2p½ F=1 F=0 2s½ RF F=1 Simulated Spectra Gnat 20 MHz

  7. Standard collinear measurements are limited by the uncertainty of the acceleration voltage Use “simultaneous” collinear-anticollinear measurement and absolute frequency determination with a frequency comb Field shift is too small in light isotopes FS constant in Be+ 2s-2p is considerably larger than in lithium 2s-2p or 2s-3s since the electron is stronger bound  Charge radii can be measured to a good accuracy with COLLAPS if we apply "new" techniques ! Why COLLAPS ?

  8. Approach Frequency Comb

  9. Frequency Comb Dn RF Comparator Wavemeter Dye Laser 1 Dye Laser 2 Feedback l/2 PBC Collinear Laser Beam Laser Beam 1 Frequency Doubler 1 Nd:Yag Laser l/2 Frequency Doubler 2 Anti-Collinear Laser Beam Laser Beam 2 Laser System for Beryllium Spectroscopy Iodine Spectroscopy Feedback

  10. Iodine Lines for the 9Be+ 2s1/2 2p1/2transition (cg)

  11. Comb-Laser Measurement Procedure Frequency I2 Frequency Voltage

  12. Previous successful beryllium measurement at COLLAPS 85 MHz 1450 2900 4350 0 Doppler-tuning frequency (MHz) Be Hyperfine Measurements at COLLAPS + Mass shift calculations by G.W.F. Drake and Z.-C. Yan / K. Pachucki: → Exakt position of Be Resonances within a few MHz

  13. Absolute frequency determination Line center accuracy 1 MHz 1 mrad Laser – Ion Beam Angle 0.005 MHz 1 mrad Missalignment of laser beams 0.75 MHz Clock-related comb uncertainty < 0.10 MHz Total Uncertainty < 2 MHz IS determination (differential effects) Line center accuracy <1 MHz 1 mrad Laser – Ion Beam Angle 0.005 MHz 1 mrad Missalignment of laser beams 0.075 MHz Total Uncertainty ~ 1 MHz Reachable Accuracy

  14. Test Beamtime in April / May ( 8 shifts) On-line Run in June / July (16 shifts) Beamtime Request and Schedule Summary : A nuclear charge radius determination of 7,9,10Be and the 1-Neutron Halo Nucleus 11Be with an accuracy of better than 5% Rc is feasible by frequency-comb based collinear laser spectroscopy at COLLAPS.

  15. Be-Isotope properties

More Related