1 / 26

Statistical Process Control

Statistical Process Control. Using Control Charts to Monitor “Quality”. Walter Shewhart. Developer of Control Charts in the late 1920’s. www.york.ac.uk/.../ histstat/people/welcome.htm. Statistical Process Control. SPC does not refer to a particular technique, algorithm or procedure

Download Presentation

Statistical Process Control

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Statistical Process Control Using Control Charts to Monitor “Quality”

  2. Walter Shewhart Developer of Control Charts in the late 1920’s www.york.ac.uk/.../ histstat/people/welcome.htm

  3. Statistical Process Control • SPC does not refer to a particular technique, algorithm or procedure • SPC is an optimisation philosophy concerned with continuous process improvements, using a collection of (statistical) tools for • data and process analysis • making inferences about process behaviour • decision making http://lorien.ncl.ac.uk/ming/spc/spc1.htm

  4. Ultimately, SPC seeks to maximize profit by: • improving product quality • improving productivity • streamlining process • reducing wastage • reducing emissions • improving customer service, etc. http://lorien.ncl.ac.uk/ming/spc/spc1.htm

  5. Control Charts • Control charts are particularly useful for monitoring quality and giving early warnings that a process may be going “Out of Control” and on its way to producing defective parts.

  6. http://www.pqsystems.com/products/SPC/CHARTrunner/CHARTrunnerChartingExample1.phphttp://www.pqsystems.com/products/SPC/CHARTrunner/CHARTrunnerChartingExample1.php

  7. Objectives • Be able to explain how control charts relate to assigned dimension and tolerance • State what value you get from control charts • Be able to name several ways that control charts indicate that a process is “out of control”

  8. Reminder: Normal Distribution Defined by two parameters: mean and standard deviation http://www.campbell.berry.edu/faculty/jgrout/spclecture.ppt

  9. 2.500.05 Example: Suppose we specify a dimension and tolerance as shown. Questions: - What does the control chart look like? - How does control chart relate to the tolerances?

  10. Control charts are normal distributions with an added time dimension http://lorien.ncl.ac.uk/ming/spc/spc8.htm#interpretation

  11. Control charts provide a graphical means for testing hypotheses about the data being monitored. Consider the commonly used Shewhart Chart as an example. http://lorien.ncl.ac.uk/ming/spc/spc8.htm#interpretation

  12. What does the control chart look like? - First we measure a number of parts as they come off the line. - For example we might measure 4 parts per hour for 20 hours. - Those 80 parts would give us an overall mean and standard deviation that would define the control chart. - The average of the size of the four parts would give us the y values for each hour (plotted on the x-axis) +3  -3 Time

  13. How does the control chart relate to the tolerances? Assigned Tolerances 2.55 2.45 -3 +3 Measured Variation

  14. Value of Control Charts • Defect Prevention through “Early Warning” • Prevent “Over-Tweaking” of Process • Assures that Process is Working • Provides Information on “Process Capability”

  15. Defect Prevention • When you see signs that the process is “out of control” you can look for and fix the causes before you make bad parts. • The control chart can help you distinguish between “common cause” and “special cause” problems.

  16. Q - How do you know a process is “out of control”? A – When the data aren’t “normal” “Out of Control” cues include - Points outside of control limits (3σ) - 8 consecutive points on one side of center line - 2 of 3 consecutive points outside the 2 limits - 4 of 5 points outside the 1  limits - 7 consecutive points trending up or down

  17. Screen Dump from MiniTab

  18. Prevent “Over-Tweaking” • Without understanding of the statistics you can chase your tail trying to get rid of variation

  19. Process Capability • Comparing the control chart information with the tolerance specification tells you about the process capability.

  20. The capability index is defined as: Cp = (allowable range)/6s = (USL - LSL)/6s LSL USL (Upper Specification Limit) LCL UCL (Upper Control Limit) http://lorien.ncl.ac.uk/ming/spc/spc9.htm

  21. The process performance index takes account of the mean (m) and is defined as: Cpk = min[ (USL - m)/3s, (m - LSL)/3ss ] LSL USL (Upper Specification Limit) LCL UCL (Upper Control Limit) http://lorien.ncl.ac.uk/ming/spc/spc9.htm

  22. Process Capability Assigned Tolerances 2.45 2.55 Good CPK>1 -3 +3 Measured Variation Poor CPK<1 -3 +3

  23. Tolerance Stackups

  24. Tolerance Stack-up for an O-Ring www.afmusa.com/doc_ generator.asp?doc_id=1238

  25. How to calculate Stack-up • WC – Worst Case (add all the tolerances at full value) • RSS – Root Sum Squared (add the tolerances statistically) • Monte Carlo (use part distribution data to predict the distribution of the added tolerances)