Analyzing Gun Shot Residue using the ICP and AA

Colleen Justison and Shelby Bleile. Analyzing Gun Shot Residue using the ICP and AA. Atomic Absorption . Inductively Coupled Plasma . Gun Shot Residue . Gun powder burns quickly to produce rapid expansion of gas

abba
Download Presentation

Analyzing Gun Shot Residue using the ICP and AA

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Colleen Justison and Shelby Bleile Analyzing Gun Shot Residue using the ICP and AA

  2. Atomic Absorption

  3. Inductively Coupled Plasma

  4. Gun Shot Residue • Gun powder burns quickly to produce rapid expansion of gas • The three major elements are lead (Pb), barium (Ba), or antimony (Sb).

  5. Purpose • The purpose of our experiment was to observe the residue left on a person that had been shot at two different distances and angles. • We used the AA and ICP to analyze the shirts and determine the amount of Barium and Lead found on them.

  6. Procedure Day One • Cut t-shirts into “10x10” pieces. • Shot a 9 mm • Cut the shirts in half to give a total of 24 samples.

  7. Setup

  8. Before & After

  9. ProcedureDay Two • We made a 0.3 M solution of nitric acid from a 16 M solution. • Used to soak the t-shirts to remove the solid from the shirts and put it into solution. • Made standards of Lead and Barium. 1, 5, 10, 15, 20, 25 ppm. • Let the shirts soak in the acid for 24 hours.

  10. Procedure Day Three • Filtered the shirts. Using vacuum filtration setup we filtered the 24 samples.

  11. ProdecureDay four • Ran our standards and samples using the AA. • found that we needed to make higher concentrated standards because we had residue at higher ppm. • The new standards we made were 10, 20, 40, 60, and 80 ppm of Lead and Barium.

  12. ProcedureDay Four Cont. • We ran all 24 samples on both the ICP and AA. • We found that the ppm was greater on the AA then on the ICP.

  13. Data: Calibration Curves

  14. Data: Calibration Curves

  15. ICP Calibration • Barium Coefficient: 0.9886 • Equation: y=623897x+1313.6 • Lead Coefficient: 0.9998 • Equation: y=1342.66x+24.6818

  16. ICP Data 6 inch Samples

  17. ICP Data 12 inch Samples

  18. AA Data- 6 inch Samples

  19. AA Data-12 inch Samples

  20. Comparisons

  21. Comparisons – Contd.

  22. Comparisons – Contd.

  23. Comparisons – Contd.

  24. Comparisons – Contd.

  25. Comparisons – Contd.

  26. Conclusions • In general, the gun shot residue contained more Lead then it did Barium. • We saw higher numbers from the AA because it has lower interference. • The top of the angled shirts showed more metals than the bottom half. • The bottom of the straight shirts showed more metals than the bottom half. • The distances did not differ as much as expected.

  27. Future Work • Use different guns/bullets and test for metals • Test for Antimony as well as Lead and Barium • Shoot from more angles and distances • Use the XRF to observe the samples

  28. Acknowledgements Thank you to Chris for making our lives a lot easier during this project and for Andrew for putting up with us all semester. Thank you to the Chemistry department for funding our experiment