An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. R PHOTO STABILITY TEST CHAMBERS

  2. R PHOTOSTABILITY TEST CHAMBERS TECHNOLOGIES PVT. LTD.

  3. R TEMPERATURE CONTROL Weiber Photostability Test Chambers are widely used for The temperature inside the photo stability test chamber is confirmatory studies as per ICH GUIDELINES (ICH Q1B) controlled by intelligent programmable temperature for direct comparison of drug substance under controlled controller and indicator. This controller is based on the environmental conditions, where samples are exposed to microcontroller nano watt technology and its ergonomic light illumination level of 1.2 million lux ,which is effectively design suits for any specific requirement of the controlled through a programmable illumination controller photostability test chambers like Data logger facility, and ulta violet light module incorporated in the same diffuser Thermal and DOT Matrix interface, direct data load facility in module with protection coating, designed to provide a UV computer office automation software like MS-Word and light energy which can also be controlled from 200 watt hour Excel and many other features listed in the specification per sq m.to allow direct comparisons to be made between below. the drug substance and drug product. HUMIDITY RANGE MATERIAL OF CONSTRUCTION 40% to 95% RH (Accuracy: + 2%) HUMIDITY CONTROL SYSTEM Castor wheel mounted cabinet is double walled with inner The WEIBER” Photo Stabiliy Chamber uses a chamber of Stainless steel sheet of grade SS 304 and outer microprocessor based, electronic humidity sensor detector wall of heavy gauge PCRC steel. sheet duly degreased and is an exact logarithmic function of the humidity pre treated with primers for rust proofing duly painted with concentration in the environment of the chamber between attractive stove enamel or powder coated. source and detector. Advanced design provides a very TEMPERATURE RANGE stable drift-free output requiring less frequent calibration. 10 Degree C to 60 degree C (Accuracy: + 0.5o C) TECHNOLOGIES PVT. LTD.

  4. R ILLUMINATION Our photostability test chamber/pharmaceutical light up when the set temperature is lower than the ambient photostability test chamber conforms to the illumination temperature. requirement as per the International Conference on 3) Temperature Alarm Harmonisation of Technical Requirements for Registration This LED indicated the extreme Ambient condition and the of Pharmaceuticals for Human Use (ICH) ICH GUIDELINES temperature failure condition. (ICH Q1B). The unit is provided with four fluorescent light 4) Audio Alarm mounted in a diffuser enclosure at the top of the chamber This Alarm indicates the visual alarm and indiactes any providing minimum illumination level of 1.2 million lux, failure and Temperature overshoot conditions. Which iseffectively controlled through a programmable 5) Door Open illumination controller. This unit is combined with a ulta violet light module incorporated in the same diffuser module with Visual indication with door open conditions. protection coating, designed to provide a UV light energy 6) A.C Power failure which can also be controlled from 200 watt hour per sq. This visual indicator light up when the mains power fail and 1) Heater Mode the system working in the battery mode. This LED indicates the heating system on condition and it 7) Low battery indicator light up when the set temperature is higher than the ambient This LED indicates the battery backup status, This LED temperature. indicates when the battery charge capacity available at 25% 2) Cooling Mode of the total charge. This LED indicates the cooling system on condition and it TECHNOLOGIES PVT. LTD.

  5. R 8) UP Count up key. After completion of all correct setting press ESC key to return back to the main menu. 9) SET OPTIONAL FEATURES (Can Be incorpora- ted At Extra Cost If Desired) This is a set button to set any parameter on the screen, by pressing of this key a cursor blink on the corresponding Temperature set point controls relays for refrigeration Ÿ parameter, So you can select any desired parameter and compressor and evaporator fan. use UP and Down key to set specific value/setting. Relays rated min. 200VAC: (a) Compressor: min. 8 A, Ÿ 10) TEMPERATURE DISPLAY min. 60 LRA, (b) Fan: min. 4 A, (c) High/low temp This seven segment display indicates the read temperature alarm. Audio and Visual Alarm. Programmable. value inside the chamber. Ÿ Alarm mute w/ ring back in 5 minutes. Ÿ SYSTEM SETTING Touch Button Control for Alarm Mute/Ring Back. Ÿ DATE and TIME : From normal operational mode, press Keyed alarm silence switch. Ÿ SET key ones, The cursor blinks at DATE (20), and for External Keyed Alarm Mute. Alternate: Supervisor Ÿ second press of KEY SET the cursor blinks at MONTH ( 12 ), programmable code. and similary on Third press of key SET cursor blinks at Door Buzzer alarm. Ÿ YEAR and repeat the steps to move to any parameter. IR Sensor/ Micro Switch Based Door open Alarm. Ÿ Similary you move cursor on any parameter and set desired Adjustable or fixed 30s delay before alarm. value for system operation. To increase any parameter use Power failure alarm: Automatic Power detection and Ÿ Audio Visual Alarm. Adjustable or fixed 15 min delay UP key and to decrease any parameter use DOWN key. before alarm. TECHNOLOGIES PVT. LTD.

  6. R MINERAL GLASS WOOL INSULATION Programmable temp range: Touch Button Control to Ÿ Glass mineral wool is one of the most environmentally Program Temperature. User Settable. friendly, stable and sustainable insulants available. Glass Battery backup: Automatic Battery Charging Facility Ÿ wool is incombustible by nature. Euro class classification is inbuilt in circuit. Provides up to 24 hr of display power. A. It does not propagate flames and toxic smokes. Thanks to Mounted temp probe. Ÿ a dense entanglement of materials with a low conduction R.F based Remote Alarm System. Ÿ and trapping a great amount of air, glass wool is a an Built-in chart recorder/Thermal Printer standard for Ÿ excellent thermal insulant. The thickest it is the best thermal blood bank units or data acquisition in the controller resistance it has, thus reducing heat losses in our memory which can be down loaded on a computer equipments for better sensitivity and economical through a suitable world standard interface like RS232 operations. And its impact on the environment in and/or RS485. manufacture, use and disposal is minimal. RS-232 I/O Port Provided. Ÿ Serial Thermal Printing facility. Ÿ AIR CIRCULATION 24 hr non-volatile temperature Record Storage Ÿ Triple walled back of unit is fitted with two air circulation fans Capacity, and Record Download facility in MS- for maintaining temperature uniformly throughout the WORD/Hyper terminal / MS-Excel. chamber. Up to 1 MB data storage Facility. Ÿ Seven Day Profile Timer with Real Time Clock. Ÿ FEATURES OF COAXIAL CIRCULATION FAN INSULATION Vacuum impregnated stator winding with dr. back Ÿ The gap of 75 mm between the outer and the inner wall is varnish under red baktol. filled with special grade glass wool to prevent thermal Non-Hygroscopic Ÿ losses. TECHNOLOGIES PVT. LTD.

  7. R REFRIGERATION UNIT Best IR value Ÿ Bright bar (EN - 8 class) shaft. Ÿ Refrigeration unit is formed by ISI marked Bush bearing of branded companies. Ÿ compressor/cooling kit. Of Kioloskar Copeland or Surge comparison testing in fans and pumps eliminates Tecumseh. Ÿ into turn short circulating of the stator. FEATURES STABILITY CHAMBER Pressure die-casted-rotor manufactured with zero Ÿ error. High Energy Efficiency Ÿ Boats of high accuracy. Compact Ÿ Ÿ Ozone-friendly refrigerants Ÿ DOORS Proven Technology Ÿ Full view inner glass/perspex door permits inspection of Wide Voltage Range Ÿ specimens, without disturbing the chamber temperature. Lock and Key arrangement is provided in the double walled SHELVES outer door. The unit is supplied with three shelves of stainless steel sheet. ILLUMINATION Unit is fitted with door operated illumination lamp inside the VOLTAGE chamber. 40 watt/120 volt replacement light bulb fits inside To work on 220/230V A.C. supply. the illumination cavity of the chamber. TECHNOLOGIES PVT. LTD.

  8. R TECHNICAL SPECIFICATION Min 200 Watthour/square meter Lightintensity (UV) Temperature Control Temperature Variation (time) Temperature Deviation (Spatial) Readability - - ± °C 0.5 ±°C 0.5 Accessories AutomaticDe-icing system Timer(1-999 minutesof hours) RealTimeProgram PrinterReportProgram SerialPort (Printer) Inspectionwindowin door - - 0.5l °C Optional - Temperature range 10°Cto 60°C ºC Optional - Sensor Thermocouple - Type K - Inbuilt Inbuilt Inbuilt Inbuilt - Controller Solid State digital Controller/PID optional - Rs232 - Display - LED/LCD Adjustable alarm limits - Optional Safety thermostats - - Shelves Standard /max Dimensionw,d Maxloadpershelf Permittedtotalload - - - 3 (With PID Controllers only) Temperature variation (time) SensorsThermocouple Automatic temperature setting - - Type K - - - - mm - Yes (With PID Controllers only) kg kg Adjustable limits - Y e s ( W i t h P I D Controllers only) Power Consumption - - 950-2250W 230, 1~ Nominal Power W Lightcontrol ReadabilityorSetability Lightintensity (Middlechamber) - - 5% 1.2 millionlux Nominal Voltage V % Hz 50/60 Lux Frequency TECHNOLOGIES PVT. LTD.

  9. R INTERNAL DIMENSIONS (STANDARD) (WxDxH) CAPACITY 505X830X415 mm 6 Cu.ft 570x875x550 mm 10 Cu.ft 650x900x550 mm 12 Cu.ft 700x900x650 mm 15 Cu.ft 775x900x775 mm 20 Cu.ft 825x1200x825 mm 30 Cu.ft 900x1720x800 mm 45 Cu.ft TECHNOLOGIES PVT. LTD.

  10. An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products www.acmasindia.com | www.acmasglobal.com | www.test-chambers.com TECHNOLOGIES PVT. LTD. CORPORATE OFFICE/ SHOWROOM (INDIA) Plot No. 352-353, Sector – 57 Phase- IV Kundli, Sonepat, HR 131028 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com SALES OFFICE (HONG KONG) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 | 0086- 18922303099 E-mail.: hk@acmasindia.com SALES OFFICE (RUSSIA) Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com