1 / 77

Radiation Protection

Radiation Protection. Bushong Ch. 37, 39 & 40. Units of Measurement NCRP ALARA DOSE – Cumulative Annual Patients Fetus. Entrance Skin Exposure Skin erythema dose Genetically significant dose. Objectives. Objectives. Radiation units of measurements QF – Quality Factor

adamdaniel
Download Presentation

Radiation Protection

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Radiation Protection Bushong Ch. 37, 39 & 40

  2. Units of Measurement NCRP ALARA DOSE – Cumulative Annual Patients Fetus Entrance Skin Exposure Skin erythema dose Genetically significant dose Objectives

  3. Objectives • Radiation units of measurements • QF – Quality Factor • Cardinal Rules of Radiation Protection • Personal Dose Monitoring & Field Instruments

  4. REGULATORY AGENCIES • NCRP – National Council on Radiation Protection and Measurement • Reviews recommendation for radiation protection & safety • NRC – Nuclear Regulatory Committee • Makes LAWS & enforces regulations

  5. STANDARD VS SI UNITS • R - C/kg • Rem - Sievert • Rad - Gray

  6. measurement 100 R = 1 C/kg 1Rad = 1/100 Gray 1 Rem = .01 Sievert (Rad + QF = REM) 1 REM = 10 mSv 1 Rem = 1000mRem

  7. Pg 619

  8. Permissible Occupational Dose • Annual dose: • 5 Rem / year 50 mSv / year • Cumulative Dose • 1rem x age 10mSv X age

  9. Occupational DoseANNUAL LIMITS • WHOLE BODY = 5 REMS / 5000mRem • LENS OF THE EYE = 15 REMS • EXTREMITIES = 50 REMS

  10. PUBLIC EXPOSURE • 10 % OF OCCUPATIONAL • (MUST BE MONITORED IF ABOVE 10%) • NON MEDICAL EXPOSURE • .5 RAD OR 500 MRAD • UNDER AGE 18 AND STUDENT • .1 rem 1 mSv • Pg 98 RTA BOOK

  11. OCCUPATIONAL EXPOSURES • 5 REMS / YEAR BUT NOT TO EXCEED 1.25 REM/QUARTER • OLD “MPD 5(Age – 18)” • Technologist essentially receive all exposure during fluoroscopy exams

  12. Two types of exposures • Radiation worker • Patient

  13. Effects of radiation in utero are time and dose related • Effects include: • Prenatal death, neonatal death, congenital abnormalities, malignancy inductions, general impairments of growth, genetic effects, and mental retardation.

  14. Irradiation in Utero • The first trimester is the most radiosensitive period. After the 2 weeks of fertilization • The first 2 weeks of pregnancy may be of least concern because the response is all or nothing

  15. After 200 rads delivered at various times

  16. Declared Pregnant Worker • Must declare pregnancy – 2 badges provided • 1 worn at collar (Mother’s exposure) • 1 worn inside apron at waist level Under 5 rad – negligible risk Risk increases above 15 rad Recommend abortion (spontaneous) 25 rad (“Baby exposure” approx 1/1000 of ESE)

  17. Pregnancy & Embryo Mother – occupational worker (5 rem) • Baby – (500 mRem) • .5 rem/ year .05 rem/month • 5 mSv .5 mSv / month

  18. Pregnant patient • ALWAYS ASK LMP before exposure made • “10-day Rule” No longer used • “Grace period” of implantation • What is the State Law for gonadal shielding?

  19. Pregnant Patients • Should never knowingly expose a pregnant patient unless a documented decision to so has been made • If you must expose; use precise collimation & protective shields. Use a high kVp technique and only the minimal projections

  20. Unsuspected pregnancy • Always screen female patients for last LMP • don’t assume ages (patient privacy) • If unsure obtain a blood test or reschedule exam if possible

  21. PREGNANT PATIENTS • Ascertain LMP - if fetus is exposed • Medical Physicist will need information: • Which x-ray machine used (mr/mas) • # Of projections (including repeats) • Technique for each exposure • SID • Patient measurement at C/R • Fluoro time & technique used • Physicist will calculate fetal dose

  22. Patient dose • Is reported in Entrance Skin Exposure (ESE)

  23. Over Radiation to SkinToo much time under beam Skin burns from 30 min of beam on time

  24. SED • SKIN ERYTHEMA DOSE • LINEAR – NONTHRESHOLD • DEPENDANT ON • DOSE RECEIVED • PERIOD OF TIME OVER IT WAS RECEIVED • AREA OF IRRADIATED TISSUE • SENSITIVITY

  25. Protective shielding • Gonads • Breasts • Thyroid • Lenses of the eyes • Long bones (bone marrow)

  26. PEDIATRIC EXPOSURE • More sensitive to radiation than adults • Limit beam time • May remove grid (reduce exposure) • Collimation & shielding !!!!!!!!!!!!!!! • Gender differences • Immobilization

  27. GSD • GENETICALY SIGNIFICANT DOSE • Takes all of the population into account • Annual AVERAGE gonadal dose to population of childbearing age • 0. 20 mSv or 20 millirem

  28. REDUCING REPEATS • TECHNIQUE CHARTS • CAREFUL REVIEW OF TECHNICAL FACTORS • REFER TO TECHNIQUE BOOK AND • ASK WHEN YOU ARE NOT SURE!

  29. CARDINAL RULESOF RADIATION PROTECTION • TIME • DISTANCE • SHIELDING

  30. Filtration REDUCES PATIENT EXPOSURES • REMOVES LOW ENERGY PHOTONS

  31. In terms of patient dose…whatis the best combination to reduce exposure to your patent? • Beam filtration More or Less? • mAs High or Low? • kVp High or Low? • Grid or Not to Grid?

  32. In terms of patient dose…whatis the best combination to reduce exposure to your patent? • Beam filtration More or Less? • mAs High or Low? • kVp High or Low?

  33. SHEILDING TECHNOLOGIST . 25 mm LEAD • LEAD APRON, GLOVES • THYROID SHIELD, GLASSES PATIENT – GONAD SHEILDING . 5 mm LEAD

  34. GONAD SHIELDING • MUST BE . 5 MM OF LEAD • MUST BE USED WHEN GONADS WILL LIE WITHING 5 CM OF THE COLLIMATED AREA (RHB) • KUB. Lumbar Spine Pelvis • male vs female shielding

  35. Lead protective aprons • 0.5 mm lead equivalent. Provides approximately 90% attenuation at 75 kVp • 1.0 mm lead equivalent is available but not practical because of the weight and potential back problems

  36. TYPES OF SHEILDING • FLAT /CONTACT • SHAPED • SHADOW

  37. Which shielding type is best for Males? Females? • Males = Shaped • Females = Flat contact

  38. Breast ShieldShadow shields

More Related