An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Long Term Testing of the Gamma-ray Large Area Space Telescope (GLAST) Detectors Kamal Prasad

  2. Acknowledgements: • Professor Robert Johnson • Gwelen Paliaga • Bill Rowe • Alec Webster • Aurore Simonnet (illustrations)

  3. GLAST will look at… • Black Holes • Active Galactic Nuclei • Pulsars • Supernova Remnants • Gamma-ray Bursts…

  4. GLAST will… • continue where EGRET left off • be 30 times more sensitive • observe gamma-ray sources in the .01 to 300 GeV Range • rely on direct interaction with gamma-ray products • use Silicon Strip Detectors (SSDs)

  5. Case for SSDs • relatively low voltage operation • high signal-to-noise ratio • reliability and robustness • precision tracking • low cost

  6. Long Term Testing • Apply constant voltage to sample detectors and observe functionality over time • Study operation of detectors in presence of construction material e.g. different epoxies • Observe salt contaminated detectors This ensures the assembly, storage and functionality of detectors as the launch date approaches.

  7. Experimental Setup

  8. Light tight box

  9. Vector board

  10. LABView Program …..

  11. ….. FORTRAN program to compile and analyze data

  12. divide and rearrange Normalizing the current A = .0883

  13. So far… • experimental setup is over (just add detectors) • data acquisition and compilation is completed • sample data has been analyzed and everything looks good Tests will run until 2003