An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recent progress Jamie 29th Feb 08

  2. Shapers Samplers -source +source • What we got

  3. Shapers Samplers -source +source • What we expect

  4. (sat limit means thresholds cannot be set above this value; capped) Shapers Samplers • What if? -source +source

  5. Manual Threshold Scan To check there are no ill-effects from driving the threshold directly with the DACs, some PCB pins were lifted and the global VTH lines driven from a power supply. (The number of hits was estimated from the typical time between ORE2 and ORE3 observed on the logic analyser) Sensor 16 (5um epi + DPW) DAC pins were re-attached and an automated scan performed for comparison

  6. Threshold Behaviour Test command: { diodeDrive 20 10 5 2600 2563 } injects a signal into the test pixel that gives a ~210mV step response, ie similar to Fe55 peak. The threshold is scanned (manually) and the output of the comparator observed with respect to the input: The value of (signal-reset) is plotted when the comparator fires. Doesn’t show the upper range of the threshold, just how it detects a “Fe55-like” signal

  7. Threshold Behaviour Test command: { diodeDrive 20 10 5 2600 2563 } injects a signal into the test pixel that gives a ~210mV step response, ie similar to Fe55 peak. The threshold is scanned (manually) and the output of the comparator observed (by eye) on the oscilloscope: An estimate is made of the correct operation of the comparator (a value >0% and <100% indicates noise on the comparator output)

  8. Threshold Common-Mode 097 = 2048 099 = 3584 101 = 3072 108 = 2560 106 = 2048 110 = 1536 112 = 1024

  9. Some different masks 106 = all active 105 = alt rows masked 114 = alt cols masked 113 = no neighbours Renato’s Gaussian fits

  10. Jumper options • J23: Substrate • GNDA (analog, default) • GNDD (digital) • NONE (floating) • J24: VRST • VDDA1V8pix (default) • DAC • Au BASE PLATE • Floating • Grounded (2-3) GNDD (1-2) GNDA (2-3) VDAC (1-2) VDDA

  11. Substrate connection J23 • 150 • 151 GNDD • 152 • 153 • 154 GNDA • 155 • 156 • NONE • 158

  12. Vrst connection J24 134 135 VDDA 142 138 140 VDAC

  13. Base plate grounding 134 135 FLOAT 142 153 154 GNDED 155