An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Using MICROWAVE REACTOR Krystyna R. Brzezinska Materials Research Laboratory

  2. Collective name for electromagnetic irradiation with • frequencies in the range of 0.3-300 GHz. • To avoid interferences between applications - • 2.45 GHz corresponding to wavelength 12.2 cm. • temp: 60-250 °C, temp increase: 2-5 °C/sec • Power: 0-300 W at 2.45 MHz Pressure: 0-20 bar • Pressure: 0-20 bar20 bar = 290 psi, 250 psi = 17 bar Microwave

  3. Mechanism of Microwave Heating Dipolar oscillation Ionic conduction Molecular Orientation = Molecular Friction = Heat

  4. Speed Up Chemical Reaction? • Temp. up to 250 oC and pressure up to 20 bars • Heat much faster than the conventional reaction. Vials: 0.2-0.5 ml, 0.5-2 ml, 2-5 ml, 10-20 ml

  5. Polar Solvents • Polar solvents (e.g. DMF, DMSO, ROH etc.) • Heat rapidly. • Same concentration as conventional reaction. • Polar solvent with high ionic content (e.g. DMF + K2CO3 etc) • Heat VERY rapidly and may overshoot set temperature. Temp too high! • Decrease initialpower use: • ‘Sample Absorption’ - High or Very High. • Dilute reaction mixture.

  6. Less Polar Solvents Less polar solvents (e.g. toluene, dioxane, THF) • Heat poorly • Concentrate the reaction mixture • - speeds workup • - lower cost of ‘waste’ solvent removal • Add polar co-solvent • Increase ionic concentration

  7. Solvent polarity Effect of a co-solvent Set temp: 200 °C 4.5 mL Toluene 4.0 Toluene + 0.5 mL DMF

  8. Reaction rate? Arrhenius Equation: K = A e–DG/RT Reaction rate ~ doubles for every 10 oC temperature increase

  9. Using the 10o Rule to determine a starting point K = A e–DG/RT

  10. Prepare Three Vials 180oC 5 min 160oC 5 min 140oC 5 min First Choice

  11. Temperatures and pressures measured* with some common organic solvents _______________________________________________________________________________________________ Solvent BP Temp Pressure** (°C) (°C) (bar) _______________________________________________________________________________________________ N,N-Dimethylformamide (DMF) 153 250 5 Water 100 220 16 Ethanol 78 180 16 Methanol 65 160 17 N-Methylpyrrolidinone (NMP)202 220 5 Ammonium hydroxide (28%) - 15019 Dimethylsulfoxide (DMSO)189 250 5 Pyridine 115 220 8 1,2-Dimethoxyethane (DME)85 200 6 Dichloromethane 40 140 15 Acetonitrile 86 200 10 o-Dichlorobenzene 190 250 2 1,4-Dioxane 101 200 4 Acetone 56 150 5 Tetrahydrofuran (THF) 65-67 180 12 Xylene 137-138 150 2 1,2-Dichloroethane 83 170 2 Toluene 110 170 4 Diethyl ether 35 135 4 *This is a general table with data generated under various reaction conditions. The actual temperature and pressure achieved with a given solvent might differ significantly using different reaction conditions and compositions. Red indicates good microwave absorption, while Blue indicates less good**Volume = 2.5 mL

  12. Reaction is not proceeding at all or not going to completion: • Increase temp. (limit is pressure buil-up in the vial and security max = 250 oC). • Extend reaction time. • Increase initialpower ‘Sample Absorption’ – Normal, High or Very High • Increase concentration. • Use more polar solvent (water at high temp become less polar). • Add polar co-solvent

  13. Decomposition: • Lower temperature. • Increase initialpower ‘Sample Absorption’ – Normal, High or Very High • Shorten reaction time. Product is actually formed, but then decomposes rapidly at elevated temperatures. • Decrease concentration. • Change reagents.

  14. Questions? Please contact Krystyna (kbrzez@mrl.ucsb.edu) -------------------------------------------------------------------------- Login: Faces Scheduling System Group: MRLPOLY User name: kkk@ Password: system will generate for you Account: please send request to Krystyna by E-MAIL ---------------------------------------------------------------------------- Go to: http://microwave.mrl.ucsb.edu/ Instrument options: status, results, online help, print etc from your office  Please clean memory of the Microwave R.