Second generation: Collamer ™ (?) Fyodorov lens

Second generation: Collamer ™ (?) Fyodorov lens. Third generation: Staar ICL. -Material: Hydrophilic collagen polymer (63% hydroxy-ethyl-methyl-acrylate; 0.2% porcine collagen; 3.4% benzofenone for UV absorption) -Water content: 34% -Refractive index: 1.45 -Optical zone: 4.5-5.5 mm

adonai
Download Presentation

Second generation: Collamer ™ (?) Fyodorov lens

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Second generation: Collamer™ (?) Fyodorov lens

  2. Third generation: Staar ICL -Material: Hydrophilic collagen polymer (63% hydroxy-ethyl-methyl-acrylate; 0.2% porcine collagen; 3.4% benzofenone for UV absorption) -Water content: 34% -Refractive index: 1.45 -Optical zone: 4.5-5.5 mm -11.0-13.0 mm long; 7.0 mm wide -Thickness: 50 mm at the optic zone; 500-600 mm at the haptic zone; 100 mm at the haptic footplates

  3. Third generation: Staar ICL

  4. Third generation: Medennium PRL -Material: Highly purified silicone -Refractive index: 1.46 -Optical diameter: 4.5-5.0 mm -10.8 or 11.3 mm long -6.0 mm wide -“One-size-fits-all” design -Not fixed in the ciliary sulcus; “floating” on the natural crystalline lens

  5. Third generation: Medennium PRL

  6. Phakic posterior chamber IOLs • Cells involved in crystalline lens and capsular bag opacification • Evolution of designs of PPCIOLs • Relevant aspects of fixation and sizing • Sizing issue: New studies • Surgical implantation • Relationship between cataract and myopia • Cataractogenesis • Specimens analyzed in our Center • Mechanisms • Review of the literature • Classification of cataracts after phakic IOL implantation?

  7. Second generation: Chiron-Adatomed silicone lens

  8. Second generation: Chiron-Adatomed silicone lens

  9. Third generation: Staar ICL -Consecutive “V” models with different vaulting characteristics in order to reduce the possibility of cataractogenesis -Correct lens sizing is important: too large excessive vaulting too small instability/decentration

  10. Third generation: Staar ICL Oversized ICL F. Trindade, MD, PhD, “Proper size, positioning of ICL are crucial”, Ophthalmology Times, October 15, 2000; 106.

  11. Third generation: Staar ICL Central vault/ midperipheral contact F. Trindade, MD, PhD, “Proper size, positioning of ICL are crucial”, Ophthalmology Times, October 15, 2000; 106.

  12. Third generation: Staar ICL Undersized ICL F. Trindade, MD, PhD, “Proper size, positioning of ICL are crucial”, Ophthalmology Times, October 15, 2000; 106.

  13. Third generation: Staar ICL (Composite UBM) Trindade F, Pereira F. Exchange of a posterior chamber phakic intraocular lens in a higly myopic eye. J Cataract Refract Surg 2000; 26:773-776