Results from PHY3 Tests in DESY, Zeuthen

Results from PHY3 Tests in DESY, Zeuthen. H. Henschel. PHY3 Tests in Zeuthen. Aim - prepare a frontend test setup with powering sequencer test pulse charge injection readout ADC and data logging - evaluate the PHY3 prototype chip dynamic range linearity

affrica
Download Presentation

Results from PHY3 Tests in DESY, Zeuthen

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Results from PHY3 Testsin DESY, Zeuthen H. Henschel H. Henschel – FE Electronics

  2. PHY3 Tests in Zeuthen Aim - prepare a frontend test setup with powering sequencer test pulse charge injection readout ADC and data logging - evaluate the PHY3 prototype chip dynamic range linearity timing (peaking times & readout) H. Henschel - FE Electronics

  3. PHY3 Tests in Zeuthen Readout board for PHY3 chip with - control input/output - level shifters - biasing switches & networks - power connector - 18 FE inputs - Amplifier H. Henschel - FE Electronics

  4. PHY3 Tests in Zeuthen Test Setup: - LabView driven I/O register - 2 Pulsers for HOLD signal & Charge injection - Oscilloscope for output evaluation H. Henschel - FE Electronics

  5. PHY3 Tests in Zeuthen Input Timing hold signal is shifted w.r.t. input pulse H. Henschel - FE Electronics

  6. PHY3 Tests in Zeuthen Serialized Output (so far slow clock rate <1kHz because software generated - hardware based sequencer ordered…) H. Henschel - FE Electronics

  7. PHY3 Tests in Zeuthen PreAmp linear range measured on Channel #0 direct output H. Henschel - FE Electronics

  8. PHY3 Tests in Zeuthen Sequential Readout • definite charge of 0.33pC injected into one channel after the other • readout with (slow) clock, hence considerable decay of captured charge is observed H. Henschel - FE Electronics

  9. PHY3 Tests in Zeuthen Achievements - basic frontend test setup with powering sequencer (slow, software based) test pulse charge injection (manually switched) readout (to scope so far) ADC and data logging (not yet accomplished) - evaluate the PHY3 prototype chip dynamic range (gain 10 only / gain 1 branch not working?) linearity (preliminary results) timing (fast readout to be investigated) H. Henschel - FE Electronics

  10. PHY3 Tests in Zeuthen Outlook • complete measurements with PHY3 chip, use with real detector samples • operate dynamic Gain1/Gain10 switch • purchase flexible and fast sequencer, prepare a versatile program • continue with subsequent prototypes …(?) Measurements & Advice: Thanks to A. Ignatenko, W. Lange, C. de la Taille! H. Henschel - FE Electronics