1 / 64

The Thermodynamic Diagram

The Thermodynamic Diagram. Adapted by K. Droegemeier for METR 1004 from Lectures Developed by Dr. Frank Gallagher III OU School of Meteorology. What is it?.

agnes
Download Presentation

The Thermodynamic Diagram

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Thermodynamic Diagram Adapted by K. Droegemeier for METR 1004 from Lectures Developed by Dr. Frank Gallagher III OU School of Meteorology

  2. What is it? • The thermodynamic diagram, of which there exist many types, is a chart that allows meteorologists to easily assess, via quantitative graphical analysis, the stability and other properties of the atmosphere given a vertical profile of temperature and moisture (i.e., a sounding).

  3. Stve Diagram

  4. Stve Diagram to be used in this class

  5. Skew-T Log-p Diagram

  6. What Can it Be Used to Estimate? • Cloud base and cloud top height • Expected intensity of updrafts, downdrafts, and outflow winds • Likelihood of hail • Storm and cloud type (supercell, multicell, squall line) • Storm motion • Likelihood of turbulence • Likelihood of storm updraft rotation • 3D location of clouds • Precipitation amount • High temperature • Destabilization via advection, subsidence • And many others….

  7. The Stuve Diagram • Construction: Altitude in Km or 1,000’s of feet Pressure levels in mb. -400 C +300 C Temperature How high is the 500 mb level?

  8. Stve Diagram to be used in this class

  9. Thermodynamic Diagram • Saturation mixing ratio line (yellow): p It provides the saturation mixingratio associated with the dry bulbtemperature, or the mixing ratioassociated with the dew point.The same line provides both T

  10. Stve Diagram to be used in this class

  11. Thermodynamic Diagram • Saturation mixing ratio line (yellow): p It provides the saturation mixingratio associated with the dry bulbtemperature, or the mixing ratioassociated with the dew point.The same line provides both T What is ws at p=1000 mb and T=-100 C? What is the RH at 1000 mb when T=240 C and Td=130 C? If T=200 C and RH = 70%, what is Td at 1000 mb?

  12. Thermodynamic Diagram p • Dry adiabats (green): Unsaturated air that rises or sinksdoes so parallel to the dry adiabats.This line simply shows the rate oftemperature decrease with height foran unsaturated parcel. T

  13. Stve Diagram to be used in this class

  14. Thermodynamic Diagram p • Dry adiabats (green): Unsaturated air that rises or sinksdoes so parallel to the dry adiabats.This line simply shows the rate oftemperature decrease with height foran unsaturated parcel. T What is the temperature of an unsaturated air parcel at 1000 mb and T=200C if lifted to 900 mb? to 600 mb? What will be the temperature of an unsaturated air parcel at 600 mb and T= -200C if it sinks to 1000 mb?

  15. Temperature of a parcel at 1000 mb Tparcel = 20C

  16. Temperature of a parcel at 1000 mb Tparcel = 20C

  17. Parcel is unsaturated, so if liftedto 600 mb, it follows parallel toa dry adiabat (green line) – notethat the parcel goes parallel tothe NEAREST green line. Temperature of a parcel at 1000 mb Tparcel = 20C

  18. Temperature of a parcel lifted dry adiabatically to 600 mb. Tparcel = -20C Temperature of a parcel at 1000 mb Tparcel = 20C

  19. Thermodynamic Diagram • Moist (pseudo) adiabats (red): Saturated air that rises or sinksdoes so parallel to the moist adiabats.This line simply shows the rate oftemperature decrease with height fora saturated parcel. p T

  20. Stve Diagram to be used in this class

  21. Thermodynamic Diagram • Moist (pseudo) adiabats (red): Saturated air that rises or sinksdoes so parallel to the moist adiabats.This line simply shows the rate oftemperature decrease with height fora saturated parcel. p T Problem: (a) Moist air rising from the surface (T=12oC) will have a temperature of _________ at 1 km. (b) If dry, the temperature will be? Why? (a) T = 12oC + (-6oC km-1) x (1 km) = 6oC (b) T = 12oC + (-10oC km-1) x (1 km) = 2oC

  22. Using the Thermodynamic Diagram to Assess Atmospheric Stability

  23. The Thermodynamic Diagram • We’ll use two types of thermodynamic diagrams in this class. • The simpler of the two is the Stve diagram, and we’ll use this to familiarize you with the use of such diagrams • The more popular (in the U.S.) and more useful is the Skew-T Log-p diagram, which we’ll apply later.

  24. Stve diagram Green Dry Adiabats Red Moist Adiabats Yellow Saturation Mixing Ratio

  25. Thermodynamic Diagram • Stability: To determine the stability you must plot a sounding. A sounding is the temperature at various heights as measured by a balloon-borne radiosonde. p The sounding is also called the environmental lapse rate (ELR). COLD WARM T Note: We also plot dew point on the chart -- we’ll get to that later.

  26. Types of Stability Unsat Sat

  27. Stability May Vary With Height Stable

  28. Example: Dry Neutral Neutral to Dry Processes Unstable to Moist Processes ELR

  29. Example: Moist Neutral Stable to Dry Processes Neutral to Moist Processes ELR

  30. Example: Absolutely Unstable Unstable to Dry Processes Unstable to Moist Processes ELR

  31. Example: Conditionally Unstable Stable to Dry Processes Unstable to Moist Processes ELR

  32. Example: Absolutely Stable Stable to Dry Processes Stable to Moist Processes ELR

  33. Norman Sounding3 February 1999 Temperature Sounding Dew Point Sounding

  34. Definitions • Lifting Condensation Level (LCL) • The level to which a parcel must be raised dry adiabatically, and at constant mixing ratio, in order to achieve saturation • It is determined by lifting the surface dew point upward along a mixing ratio line, and the surface temperature upward along a dry adiabat, until they intersect.

  35. Example: LCL Notes: Dry adiabatic ascent from surface Constant mixing ratioRH increasesas parcelascends (T and Td approachone another; RH is 100% at LCL Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 Data at LCL TLCL = 2oC Mixing Ratio = 5 g kg-1 LCL = 900 mb Td T

  36. Definitions • Lifting Condensation Level (LCL) • The LCL is CLOUD BASE HEIGHT for a parcel lifted mechanically, e.g., by a front. Remember, it is the LIFTED OR LIFTING condensation level.

  37. Example: LCL Notes: Dry adiabatic ascent from surface Constant mixing ratioRH increasesas parcelascends (T and Td approachone another; RH is 100% at LCL Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 LCL = 900 mb Td T

  38. Definitions • Level of Free Convection (LFC) • The level to which a parcel must be lifted in order for its temperature to become equal to that of the environment. • It is found by lifting a parcel vertically until it becomes saturated, and then lifting it further until the temperature of the parcel crosses the ELR

  39. Example: LFC LFC = 840 mb LCL = 900 mb Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 Td T

  40. Definitions • Level of Free Convection (LFC) • Any subsequent lifting will result in the parcel being warmer than the environment, i.e., instability. • This is what “free convection” means – the parcel will convect freely after reaching the LFC

  41. Example: LFC LFC = 840 mb LCL = 900 mb Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 Td T

  42. Definitions • Equilibrium Level • A level higher than the LFC above which the temperature of a rising parcel becomes equal to that of the environment, i.,e. the parcel has zero buoyancy or is in equilibrium with the environment • It is found by lifting a parcel until its temperature becomes equal to the ELR

  43. Example: LFC and EL EL = 580 mb LFC = 840 mb LCL = 900 mb Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 Td T

  44. Definitions • Equilibrium Level • Any subsequent lifting above the EL leads to stability • The EL marks the “top” of thunderstorms, though in reality the upward momentum of updraft air makes thunderstorms overshoot the EL (overshooting top)

  45. Example: LFC and EL EL = 580 mb LFC = 840 mb LCL = 900 mb Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 Td T

  46. Definitions • Convective Condensation Level • The level at which convective clouds will form due to surface heating alone. • It is found by taking the surface dew point upward along a mixing ratio line until it intersects the ELR. • Convective Temperature (Tc) • The temperature required at the ground for convective clouds to form. • It is found by taking a parcel at the CCL downward along a dry adiabat to the surface.

  47. Example: LCL, CCL, and Tc CCL = 750 mb LCL = 900 mb Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 Tc = 23oC Td T

  48. Example: Positive and Negative Areas EL = 510 mb Parcel warmer than environment! Positive Area Negative Area Need to push parcel up!!!! LFC = 800 mb Surface Data T= 10oC Td = 3oC Mixing Ratio = 5 g kg-1 LCL = 900 mb Td T

More Related