Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion
Schneider Electric is the Global Leader inPre Fabricated Modular Solutions In January 2014 Schneider Electric acquired AST Modular the global leader in pre fabricated modular and containerized and modular Data Centers • AST leads the pre-fabricated Modular Data Center Market (>20% market share) • Over 600 Data Center projects successfully executed to date • Projects deployed in over 50 countries • First company to build a Tier 3 multi-Container Data Center • Pioneered the manufacturing of high quality purpose built containerized data centers (2001) • AST customers include IT leaders including IBM, HP, Dell, and Silicon Graphics
Schneider Has Deep Experience in Delivering Pre Fabricated Solutions
Our Products Include a Wide Variety of Standard and Pre-fabricated IT Room Solutions SS Standard ISO MDC – Non-ISO Smart Shelter SS Modular Rooms • 20’ & 40’ ISO • -All in one containers • -Multi container parks • 25’ & 45’ NON ISO • -All in one modules • -Contiguous IT rooms • Secure IT rooms • -Indoor & Out Door • -Secure and any size
3 Types of IT Modules for Different Applications AST IT Modules • Compact ISO All-in-One • (20ft Enclosure,7Racks, UPS, PDU, Overhead DX Cooling, • Standard ISO All-in-One • (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling • Ruggedized Solutions for Industrial (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling, Ruggedized versions available • Multi-Bay IT Modules • (25ft – 40ft enclosure, Non-ISO design for more space. Cooling options - In-Row CW Perimeter CW, Air Economizer Cooling, DCIM) • Modular Room • (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)
IT Module – Non ISO ”Wide Tall & Comfortable” Overview • Non-ISO design is wider, taller, deeper than container and engineered to provide a spacious, functional workspace for IT personnel • Efficient, scalable design allows for custom, multi-module configurations from 20 – 240 racks • Multiple cooling solutions for chilled water, DX and air economization (In-row, Perimeter, End-of-Row) • Robust frame design simplifies installation and ganging together • Best option for a complete configurable space. Walk Through Our Demo Module Outside
Multi Module Designs IT Rooms are joined together to form an “open white space” IT room
Base Designs – IT Modules IT Room Modules • 90kW All-in-One • (40ft Enclosure,10 Racks, UPS, PDU, In-Row DX Cooling, DCIM) • 110kW Single Module • (40ft Enclosure, 10 racks, PDU, In-Row CW cooling, DCIM) • 205kW Single Module (53ft Enclosure,14 racks, PDU, In-Row CW cooling, DCIM) • 240kW Dual Module • (20 x 45ft Enclosure 22 Racks, PDU, In-Row CW cooling, DCIM) • 240kW Dual Module • (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)
10 Rack 90 kW N+1 “All in One” Wide Body” Pre Fabricated Data Center
IT Module Detail 2 bay, 24 Rack In-Row, 240kW shown 24 NetShelter Racks Aisle Containment • 240kW cooling capacity • 415V distribution @11kW per rack (2N) • Power monitoring, management and controls • Fire detection and suppression • Staging lobby for outside isolation Staging Lobby and Electrical Room 415 Modular Power Distribution In-Row Cooling Units
Smart Shelter™ Prefab Modular Room ExamplePhased Deployment View of (4)100 Rack IT Bays Phase 1 100 Racks Phase 3 Phase 2 100 Racks Phase 4 Gensets Chillers
Smart Shelter™ Secure Prefab Modular Rooms • Expandable rooms are secure, water, dust & fire proof thermally insulated modular IT rooms. • Rooms are built sized to any requirement. • Installed Indoors or outdoor. • Shelters can be disassembled & relocated. • Rooms can expanded in a clean method. • No construction construction dust or debris affecting expansion while operating. • Visiting customers experience a “clean room” secure IT white space.
IT Module – ISO Shipping Container Schneider specific features Seismic Rack Mount Echain cable management Sliding Rail System
Base Designs - Power Modules Power Modules • 250kW • 20ft Enclosure with UPS, Switchgear, cooling, DCIM • 500kW • 40ft Enclosure with UPS, Switchgear, cooling, DCIM • 1.2 MW • Skid mounted, UPS, Switchgear, DCIM
Enclosed Power Modules Air Conditioners 500kW Module • Symmetra N+1 UPS(250/500kW) • 5 min Runtime • Switchboard w/ integrated ATS • Power monitoring, management and controls • Environmental cooling • Fire Suppression • UL Listed Critical Output Switchboard 500kW Symmetra PX UPS Fire Suppression System Primary Switchboard
Skid Mounted Power Module 1.2 MW Skid Shown • Allows for quick deployment within an existing building that is scalable for larger data centers. • N+1 UPS MW UPS • 5 min Runtime • Switchboard w/ integrated ATS • Power monitoring, management and controls
Cooling Modules Cooling Modules • 500kW Hydronics Modules • (Support 3-250kW Chillers) • 1000kW Hydronics Modules • (Support 3-500kW Chillers) • Chiller Skids & Enclosures • Packaged Chiller, pump, and Tank with connecting piping • 250kW – 1.2 MW Packaged Air Cooled Chillers - Options with and without free cooling • Ecobreeze ISO frame • 50kW increments up to 400kW of total cooling capacity (DCIM)
AST Cooling Offer – CW & DX (Pending UL Certification) AST added Capability Chilled Water Block Unit – CWB 100 kW Chilled water room cooling for prefabricated IT modules without raised floors • Fits both ISO and Non-ISO prefab modules • Designed to operate at higher water temperatures (15C) • Top return with front supply air discharge • Humidifier and electric reheat control options • Hot Corridor Heat Exchanger– HCX 20 kW - 40 kW • Overhead cooling for prefabricated ISO IT modules • Chilled Water or Direct Expansion • No floor space - located over the racks and hot aisle/corridor • Maintenance all done from hot aisle/corridor • Requires chilled water plant or remote condensing unit
AST Cooling Offer – Air Economizer Natural Free Cooling Unit – NFC 50 kW Indirect Free Cooling for small or constrained data center spaces • Independent operating unit • Heat Pipe heat exchanger isolating indoor and outdoor air • Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling Options • Flexibility to have external heat rejection for mechanical cooling as required - Chilled Water Plant or External Condensing Units Direct Free Cooling Unit – DFC 75 kW Direct Free Cooling for small or constrained data center spaces • Uses air directly from outside for free cooling • Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling Options • Flexibility to have external heat rejection for mechanical cooling as required • - Chilled Water Plant or External Condensing Units
Global References Utility - Australia Education - Canada Healthcare - Italy Military - Europe
Global References IT Software Company Government Customer – US Global Bank – Denmark Cloud Service Provider – Iceland
Mission-Critical Services • Consulting and Planning – Assessment, analysis, strategic planning and O&M program development services. • Design and Construction– Engineering, design-build and construction project management of facility expansions and new facility projects. • Commissioning – Data center and LEED commissioning from project inception to integrating testing. • Operations and Maintenance – Managed Services and on-site Critical Facility Management. • Energy Management– Energy assessments, system optimization, and efficiency improvement projects. • Alarm and Incident Management – 24x7 remote monitoring services through the Schneider International Operations Center (NOC). Lifecycle Service Solutions
Design-Build Benefits 2/2012 12/2013 • Schneider Design Build Outcomes • Singular Accountability/Project Ownership • Fully Integrated Project Delivery • Speed to Market – Reduced Project Timelines • Fewer Change Orders – Less Cost Overruns • Continuous Project Budgeting and Scheduling • Datacenter/Mission Critical Specific Team Skill Set • Competitively Bid All Major Cost Items
Thank you Scott Fleming Pre Fabricated Data Center Specialist scott.fleming1@schneider-electric.com (925) 963 5468 Discussion, Questions and Answers
IT Module – ISO Shipping Container Overview • ISO shipping container is defined to 8ft wide and lengths of 10ft, 20ft, 40ft, and 53ft in U.S. • Containers are designed to be strong, rugged, environmentally sound and easily transportable anywhere in the world • 8ft width limits usable space for hot and cold aisles. Height is also limited • Schneider has unique solutions for slide racks and flexible cable trays to allow full access to front and rear of racks to overcome space limitations • Overhead cooling units (DX and CW) are available to maximize rack space
One-Size Does Not Fit All Power 200kW – 1.2MW IT Space 5 Racks – 200 Racks Cooling DX – Chilled Water – Direct Air – Indirect Air