1 / 30

Proton Form Factor Measurements with Polarization Method

Proton Form Factor Measurements with Polarization Method. L.Pentchev The College of William and Mary For the GEp-2 g and GEp-III collaborations. JLab , June 8-10, 2009. Outline. GEp-III (E04-108) and GEp-2 g (E04-019) experiments

aimon
Download Presentation

Proton Form Factor Measurements with Polarization Method

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Proton Form Factor Measurements with Polarization Method L.Pentchev The College of William and Mary For the GEp-2g and GEp-III collaborations JLab , June 8-10,2009

  2. Outline • GEp-III (E04-108) and GEp-2g (E04-019) experiments • Polarization transfer method, experimental set-up, kinematics • Elastic/background separation • Spin transport in HMS • GEp-2g experiment: precise (1%) measurement of two polarization quantities; test of the limits of Born approximation in polarization method • 2g exchange theoretical calculations • Longitudinal transferred polarization (preliminary results), beam polarization measurements • e-dependence of the form factor ratio (preliminary results) • Reconstruction of the real part of the ep elastic amplitudes • GEp-III: measurement of the proton form factor at high Q2 • Preliminary results • Comparison with theoretical calculation, asymptotic behavior • Summary

  3. Polarization Method In Born (one-photon exchange) approximation: • Form Factor ratio can be obtained without knowing analyzing power, Ay, and beam helicity, h, (both cancel out in the ratio), and without measuring cross-section. • Systematic uncertainty dominated by the spin transport from the polarimeter to the target. A.I.Akhiezer and M.P.Rekalo, Sov.J.Part.Nucl. 3, 277 (1974) R.Arnold, C.Carlson, and F.Gross, Phys. Rev. C 23, 363 (1981)

  4. GEP-3 and GEP-2gamma experimental set-up in Hall C e e’ Big E.M. Calorimeter p High Momentum Spectrometer Double Focal Plane Polarimeter 1.87- 5.71 GeV beam 80-100 mA beam current 80-85% pol. 20cm LH target

  5. Detectors • Changes in standard HMS detector package: • Focal Plane Polarimeter with Double Analyzer: • -> 70% increased efficiency (30% for FOM) • Scintillator plane S0 in front of drift chambers • -> deteriorates angular resolution but needed for triggering • 1744 channel E.M. Calorimeter (BigCal): • from (due to radiation damage) needed for triggering • beter than 10 mm position resolution – most important parameter for elastic separation

  6. Goal of The Experiments • GEp-2gamma: e dependence of R at 2.5 GeV2 • KEY IDEA OF THE METHOD: FIXED Q2 • same spin transport • same analyzing power Two polarization observables are measured: Pt/Pl and Pl separately precision limited only by statistics (~ 1%), very small p.t.p systematics: Ay , h cancel out in the Pt/Pl ratio Q2 fixed, Pp fixed, spin precession fixed • GEp-3: high Q2 measurements • 5.2 GeV2 point “overlapping” with GEp-II (4.0 and 5.6 GeV2) • two higher Q2 points

  7. Data analyses: elastic separation All triggers Elastics after BigCal-HMS correlations Estimated background Range used in analyses 2.5 GeV2 e=0.15 8.5 GeV2e=0.24 s=0.10% s=0.11% Background contribution: 0.5% Correction to mR: +0.35% Background contribution: 13% Absolute correction to mR: +0.10 • (PCAL-PHMS)/P0 gives better resolution then (Pqp-PHMS)/P0, because of worse HMS angular resolution • Background estimated by interpolation, dominated by g p -> p0 p • Polarization of the background measured below the elastic peak looking at events with hits at the calorimeter outside expected position of the elastic electron (p0 -> gg)

  8. Spin transport in HMS QQQD type spectrometer: rotations are additive in the quads and total precession is sum of dispersive (main) and non-dispersive precession: Dispersive precession Non-dispersive precession Allows to use simple geometrical model, giving results very similar to COSY calculations used for the results presented here • Non-dispersive precession – the dominant source of systematics, because it mixes the two polarization components in the reaction plane • Requires very good knowledge of non-dispersive bend angle Df • uncertainty of Df used for the preliminary analyses of 1mrad • using dedicated optical studies, we expect to reduce the uncertainty by factor of ~3 2.5 GeV2 e=0.15

  9. GEp/GMp Crisis: discrepancy in the data “The discrepancy is a serious problem as it generates confusion and doubt about the whole methodology of lepton scattering experiments” P.A.M. Guichon and M.Vanderhaeghen

  10. GEp-2g: Beyond Born Approximation Mo and Tsai, and others: • prescriptions for radiative corrections commonly used • two-photon exchange: (e), (f) – only with one soft photon, neglecting proton structure

  11. Generalized Form Factors (ep elastic amplitudes) this experiment e+/e- x-section ratio Rosenbluth non-linearity Born Approximation Beyond Born Approximation P.A.M. Guichon and M.Vanderhaeghen, Phys.Rev.Lett. 91, 142303 (2003) M.P. Rekalo and E. Tomasi-Gustafsson, E.P.J. A 22, 331 (2004)

  12. Two-Photon Exchange: theoretical predictions • Hadronic calculations • P.Blunden et al., Phys.Rev.C72: 034612 (2005) elastic (at the figure) • S.Kondratyuk et al., Phys.Rev.Lett. 95: 172503 (2005) including Delta reduces the effect • S.Kondratyuk et al., nucl-th/0701003 (2007) including 1/2 and 3/2 resonances – no effect GPD A.Afanasev et al., Phys.Rev.D72:013008 (2005) – GPD models: Gauss (figure), smaller effect with Regge, or non-zero quark mass Valid at high e region (vertical line at figure) LO pQCD N. Kivel and M. Vanderhaeghen arXiv:0905.0282 [hep-ph] LO pQCD using two different distribution amplitude models: BLW (good agreement with lattice QCD!) and COZ Valid in high e region (vertical line at figure) . Both theories describe Rosenbluth data but have opposite predictions for mGE/GM

  13. Longitudinal transferred polarization: stability of the measurements Beam polarization: dominant source of systematic error for PL measurements PRELIMINARY • open circles: this experiment • (hAyPl)meas/(Plborn Ay(q)) • filled circles – Moller measurements of beam polarization (h) • open boxes (connected with line): beam polarization predicted from quantum efficiency measurements (Dave Gaskell, private comm.) • 1.873 GeV beam energy, e=0.15 • 2.846 GeV e=0.64 • 3.549 GeV e=0.78 • 3.680 GeV e=0.79

  14. Longitudinal transferred polarization: stability of the measurements • open circles: this experiment • (hAyPl)meas/(Plborn Ay(q)) • filled circles – Moller measurements of beam polarization (h) • open boxes (connected with line): beam polazrization predicted from quantum efficiency measurements (Dave Gaskell, private comm.) • 1.873 GeV beam energy, e=0.15 • 2.846 GeV e=0.64 • 3.549 GeV e=0.78 • 3.680 GeV e=0.79 PRELIMINARY

  15. Preliminary results: longitudinal polarization PRELIMINARY PRELIMINARY NO RADIATIVE CORRECTIONS APPLIED, Less than 1% (Afanasev et.al, Phys.Rev. D64 (2001) 113009) Uncertainties in the overall normalization of the data due to uncertainties in Ay Beam polarization p.t.p. systematics 0.5%

  16. Preliminary results: form factor ratio PRELIMINARY Narrow acc. matching all kinematics Wide acc. matching e=0.64 and e=0.79 Theoretical predictions are with respect to the Born approximation NO RADIATIVE CORRECTIONS APPLIED, Less than 1% (Afanasev et.al, Phys.Rev. D64 (2001) 113009)

  17. GEP3 preliminary results: FF ratio • Results at 2.5 and 5.2 GeV2 agree (within one sigma) with previous Hall A results • No zero crossing; slower decrease with Q2

  18. GEP3 results • No evidence for the Q2 F2/F1 scaling • Modified (logarithmic) scaling still holds

  19. CONCLUSIONS • GEp-2g: POLARIZATION METHOD PASSED THE TEST : no evidence for effects beyond Born approximation at 2% level in the polarization data at Q2 of 2.5 GeV2 • Slight deviations from Born approximation at two sigma level both of longitudinal polarization and of form factor ratio require further investigations: possible “standard” radiative corrections, not applied yet • The preliminary results do not exclude with high confidence any of existing 2g-exchange theoretical models; yet high-e data favor GPD and pQCD models. Expected reduction of systematic error and especially, knowledge of Born FF ratio (from e+/e- experiments) will greatly help in constraining theoretical predictions. • Measuring two polarization observables for a fixed Q2 in a wide kinematical range with 1% precision allows to constrain the real parts of both, ratio of the generalized electric to magnetic form factors, and the third non-Born amplitude contribution Y2g, without model assumptions. • GEp-III: First high Q2 proton FF ratio measurements outside Hall A confirm previous results at one sigma level, though Hall C data possibly slightly higher • New FF ratio data up to 8.5 GeV2 exhibit slower decrease with Q2 (favoring existing VMD, GPD models) still consistent with modified (logarithmic) scaling of F2/F1; no zero crossing yet • Measurements above 8.5 GeV2 with 12 GeV machine are certainly very important

  20. BACK-UP SLIDES STARTING HERE

  21. Elastic amplitude reconstruction • Three observables measured at 2.5 GeV2: • Pt/Pl • Ay*Pl • ds PRELIMINARY Important note: Elastic amplitude reconstruction is different from full Born / non-Born separation: need e+/e- data and triple polarization observables (M.P.Rekalo and E. Tomasi-Gustafsson Nucl.Phys.A740:271-286,2004) Still here one can constrain the contribution from the third non-Born amplitude Y2g. Three amplitudes (Re parts): R=mRe(GE)/Re(GM), Y2g,Re(GM) and Ay unknown Plotted: Re(GM) (ds, Pt/Pl,R), Y2g(Pt/Pl,R), Ay(Ay*Pl,R)

  22. Background corrections

  23. Two-Photon Exchange: theoretical predictions • Hadronic calculations • P.Blunden et al., Phys.Rev.C72: 034612 (2005)elastic (Figure) • S.Kondratyuk et al., Phys.Rev.Lett. 95: 172503 (2005)including Delta reduces the effect • S.Kondratyuk et al., nucl-th/0701003 (2007) including 1/2 and 3/2 resonances – no effect • Yu. Bystricky, E.A.Kuraev, E. Tomasi-Gustafsson Phys. Rev. C75, 015207 (2007)structure function method: 2g effects small, higher orders change Rosenbluth slope (Figure) • D.Borisuyk, A.KobushkinarXiv:0804.4128: proton off-shell form factors are not needed to calculate TPE amplitudes

  24. Two-Photon Exchange: theoretical predictions GPD calculations • Absolute correction to FF ratio mGe/Gm: • slow Q2 variation, strong effects at low e • valid for high Q2 or high e • A.Afanasev et al., Phys.Rev.D72:013008 (2005) – GPD models: Gauss on Fig., smaller effect with Regge, or non-zero quark mass

  25. Analyzing Power

  26. Polarization Method: Spin Transport Non-dispersive precession Dispersive precession Target Target to Reaction Plane Reaction Plane Longitudinal and transverse polarizations Pt and Pl are helicity dependent (transferred) Normal polarization Pn is helicity independent; zero in Born approximation

  27. GEp/GMp Crisis: asymptotic behavior Dirac and Pauli form factors:

  28. Polarization Method: Systematics Relate the evolution of the velocity (trajectory) to the evolution of the spin: COSY Geom. Approx. Geometrical Approx.

  29. High Q2 Measurements

More Related