1 / 12

PROTOCOL FOR DETERMINING THE BEST PERFORMING AIR QUALITY MODEL

PROTOCOL FOR DETERMINING THE BEST PERFORMING AIR QUALITY MODEL. 8 TH MODELING CONFERENCE SEPTEMBER 22, 23 2005. MODEL PROTOCOL. THESE SLIDES ARE BASED ON AN EPA DOCUMENT – EPA-454/R-92-025 – ENTITLED: “PROTOCOL FOR DETERMINING THE BEST PERFORMING MODEL” DECEMBER 1992

akamu
Download Presentation

PROTOCOL FOR DETERMINING THE BEST PERFORMING AIR QUALITY MODEL

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PROTOCOL FOR DETERMINING THE BEST PERFORMING AIR QUALITY MODEL 8TH MODELING CONFERENCE SEPTEMBER 22, 23 2005

  2. MODEL PROTOCOL • THESE SLIDES ARE BASED ON AN EPA DOCUMENT – EPA-454/R-92-025 – ENTITLED: “PROTOCOL FOR DETERMINING THE BEST PERFORMING MODEL” DECEMBER 1992 • REFERENCED IN APPENDIX W

  3. MODEL PROTOCOL • SCREENING TEST IS AVAILABLE • BASED ON FRACTIONAL BIAS (FB) • FB = 2 [PR - OB] / [OB + PR] • BASED ON THE HIGHEST 25 VALUES • IF ABSOLUTE FB EXCEEDS 0.67 (FACTOR OF 2), THE MODEL MAY BE EXCLUDED OB = OBSERVED DATA: PR = PREDICTED DATA

  4. MODEL PROTOCOL • THE MORE ADVANCED STATISTICAL TEST HAS 2 COMPONENTS • A REGULATORY COMPONENT • A SCIENTIFIC COMPONENT

  5. MODEL PROTOCOL • THE REGULATORY COMPONENT • THE PRECISE TIME, LOCATION AND METEOROLOGICAL CONDITIONS ARE NOT OF CONCERN • THE MAGNITUDE OF THE HIGHEST CONCENTRATIONS IS OF PRIMARY CONCERN

  6. MODEL PROTOCOL • THE REGULATORY COMPONENT • USES A TEST STATISTIC – THE ROBUST HIGHEST CONCENTRATION (RHC) - A SMOOTHED ESTIMATE OF THE HIGHEST CONCENTRATIONS • BASED ON A TAIL EXPONENTIAL FIT TO THE UPPER END OF THE DISTRIBUTION • GENERALLY BASED ON THE HIGHEST 25 CONCENTRATIONS • CONDUCTED FOR REGULATORY AVERAGING TIME (E.G. 3- AND 24-HOUR) • USES A PERFORMANCE MEASURE - THE FRACTIONAL BIAS OF THE RHCs

  7. MODEL PROTOCOL • THE SCIENTIFIC COMPONENT • THE LOCATION AND METEOROLOGICAL CONDITIONS ARE OF CONCERN • THE MAGNITUDE OF THE HIGHEST CONCENTRATIONS UNDER EACH CONDITION IS OF CONCERN

  8. MODEL PROTOCOL • THE SCIENTIFIC COMPONENT • USES A TEST STATISTIC – THE ROBUST HIGHEST CONCENTRATION (RHC) - A SMOOTHED ESTIMATE OF THE HIGHEST CONCENTRATIONS • BASED ON A TAIL EXPONENTIAL FIT TO THE UPPER END OF THE DISTRIBUTION • GENERALLY BASED ON THE HIGHEST 25 CONCENTRATIONS • USES A PERFORMANCE - THE FRACTIONAL BIAS OF THE RHCs • CONDUCTED FOR 1 HOUR CONCENTRATIONS • CONDUCTED FOR 2 WIND SPEED GROUPS AND 3 STABILTIY CATEGORIES

  9. MODEL PROTOCOL • COMBINE THE SCIENTIFIC AND REGULATORY COMPONENTS INTO ONE METRIC

  10. MODEL PROTOCOL • USES A COMPOSITE PERFORMANCE METRIC (CPM) CPM = 1/3 [AVERAGE AFBI,J ]+ 2/3 [AFB3 + AFB24 ] / 2 • AFBI,J = absolute fractional bias for met category i at station j • AFB3 = absolute fractional bias for 3 hour averages • AFB24 = absolute fractional bias for 24 hour averages

  11. MODEL PROTOCOL • MODEL TO MODEL COMPARISON USES THE MODEL COMPARISON MEASURE (MCM) MCMA,B = CPMA - CPMB CPMA IS A COMPOSITE PERFORMANCE MEASURE FOR MODEL A CPMB IS A COMPOSITE PERFORMANCE MEASURE FOR MODEL A

  12. MODEL PROTOCOL • THE YARDSTICK • THE RATIO OF THE 1) COMPOSITE DIFFERENCE TO THE 2) STANDARD ERROR • BLOCKED BOOTSTRAP METHOD IS USED TO GENERATE THE ESTIMATE OF THE STANDARD ERROR • RATIOS > 1.7 INDICATE A SIGNIFICANT DIFFERENCE IN THE 2 MODELS AT ABOUT 90% CONFIDENCE LEVEL

More Related