1 / 27

IBM System x

IBM System x. Nuestro Portafolio IBM. System i™. System x™. System p™. System Storage™. System z. Chip Design. Mechanical Design. Serviceability. Thermal Engineering. Reliability Features. Blade Design. Server Management. Project Big Green. Memory Subsystems. Cable Management.

alden
Download Presentation

IBM System x

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IBM System x

  2. Nuestro Portafolio IBM System i™ System x™ System p™ System Storage™ System z

  3. Chip Design Mechanical Design Serviceability Thermal Engineering Reliability Features Blade Design Server Management Project Big Green Memory Subsystems Cable Management Service & Support Rack Design Innovation @ IBM Innovation that matters -- for x86 Servers

  4. IBM BladeCenter – Right - Chassis

  5. La mayor libertad de elección de chasis, blades, almacenamiento y redes compatibles Disponibilidad con múltiples capas de redundancia Confiabilidad punta a punta y un compromiso hacia las mejores prácticas Excelente eficiencia en energía con tecnología líder en enfriamiento Gran performance de I/O y switches basados en tecnología abierta Las 5 Principales Razones para elegir IBM BladeCenter IBM BLADECENTER. LA ELECCIÓN CORRECTA

  6. Sustancial reducción de costos con BladeCenter En la compra inicial… • Más baratos que servidores rackeables • No requiere adicionales: KVM, Cables • Menor uso del espacio del rack • Mayor velocidad de instalación € ¢ £ Durante la vida del Servidor… • Bajos costos de administración • Bajo consumo de energía • Protección de la inversión $ ¥ Rs RIGHT

  7. $ Un chasis para cada necesidad del cliente Energy Efficiency: BladeCenter E Small/Distributed Office: BladeCenter S High Performance: BladeCenter H Ruggedized: BladeCenter T/HT

  8. IBM BladeCenter E: Mejor eficiencia de energía y densidad IBM BladeCenter T: NEBS, ambientes adversos IBM BladeCenter S: Oficina pequeña o distribuida, fácil de configurar IBM BladeCenter HT: Alta performance, ambientes adversos IBM BladeCenter H: Alta performance Estrategia de Chasis • Soluciones de diseño para hacer frente a las necesidades de los clientes • Costo • Performance • Tamaños • Flexibiidad de ubicación • Virtualización • Performance/watt líder en la industria 2010+ 2012+

  9. Amplio Portfolio con Protección de la Inversión 2010+ Vs. competitors disposable IT approach 2012+ BladeCenter T BladeCenter H 2006-2010+ BladeCenter E 2002-2010 BladeCenter HT BladeCenter S HP BH7800 Maybe 1 year HP p-class Almost 1.5 years X New HP p-class New HP c-class HP BH5700 (Telco) PowerEdge 1655MC X PowerEdge 1855 BC100 Sun ATCA Sun 8000 Sun 6000 2003 2002 2008 2006 2004 2007 2005

  10. Public Internet/ Intranet Clients Step 1 Consolidate Servers Routers (Layer 3 Switches) Firewalls Layer 4-7 Switches SSL Appliances SSL Appliances Layer 2 Switches Caching Appliances Caching Appliances Network Servers Application Servers Security Servers Application Servers Web Servers Security Gateway File Servers WebSphere Application Servers Storage Fibre Switches Storage Fibre Switches SAN

  11. Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls SAN Step 2 Integrate First Layer of the Network (L2) Layer 4-7 Switches SSL Appliances SSL Appliances Layer 2 Switches Caching Appliances Caching Appliances Storage Fibre Switches Storage Fibre Switches

  12. Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls SAN Step 3 Integrate Storage Fabric Layer 4-7 Switches SSL Appliances SSL Appliances Caching Appliances Caching Appliances Storage Fibre Switches Storage Fibre Switches

  13. Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls SSL Appliances SSL Appliances Caching Appliances Caching Appliances SAN Step 4 Integrate Second Layer of the Network (L4-7) Layer 4-7 Switches

  14. Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls SSL Appliances SSL Appliances Caching Appliances Caching Appliances SAN Step 5 Consolidate Applications

  15. Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls SAN Result BladeCenter Collapses Complexity

  16. Introducing IBM BladeCenter BladeCenter E - Most dense, energy-efficient blade in the market BladeCenter H – High performance and extreme I/0 flexibility RIGHT

  17. HS21 XMExtended-memory HS21General-purpose enterprise Extensión de los beneficios de Blades a todas las aplicaciones Blades hechos a medida para sus necesidades específias. JS22High-performance with native virtualization LS42Scalable, enterprise performance HC10Workstation JS12 Great ValueforAIX and IBM i LS22Green to the extreme QS22High-performance HS12Entry & SMB • Un conjunto común de Blades • Un conjunto común de switches “industry-standard” y “fabrics” de I/O • Una infraestructura común de administración RIGHT 17

  18. IBM BladeCenter Enterprise Blade Servers LS42 JS22 LS22 HS21XM HS12 JS12 HS12

  19. The IBM BladeCenter® H • 9U, 29 inches deep • Supports up to (14) 30mm blades (same as the IBM BladeCenter) • Customer serviceable, hot swappable Media Tray • Rack mounted on rails just as the IBM BladeCenter • (4) front load 2900W Power Supplies BladeCenter H (Front) Media Tray (removable) USB, indicators & DVD (4) front load 2900W PS (2 upper & 2 lower) 14 blades BladeCenter H (Back)

  20. The IBM BladeCenter® H BladeCenter H (Back) • MM • Switch Module Bays 1 & 2 (dedicated ethernet) • Switch Module Bays 3 & 4 –OR- Bridge Slots • Dedicated Bridge Module Slots (up to 4) • Blowers (2) • 4 High Speed Switch Module Bays • Light Path Diagnostic Panel • Aggregated Serial Connector • Consolidated Redundant Power Inputs (2) I I F B E A D C B A E D C aMM G F H

  21. Robust & reliable? IBM – Conexiones redundantes al midplane • IBM provides dual I/O and dual power connections to the chassis on all blades • Other major vendors fail to provide this protection Would you connect your enterprise rack server to a single PDU or a single switch? • Complete redundancy • Dual Power Connections • Dual I/O connections • Dual high speed I/O connections IBM base Blade – All blades since 2002 IBM Blades –HS21, HS21 XM, LS21, JS21 with CFFh adapter RIGHT

  22. IBM BladeCenter H Midplane – redundancia total • BCH midplane supports complete redundancy • Power Connection • Up to 8GB I/O Fabric • High Speed Fabric

  23. Cómo elegir el disco interno correcto

  24. Estado Sólido – Disco local confiable y robusto • Alternativa innovadora a los discos duros tradicionales • Ideal para ambientes de booteo con pocas escrituras • Discos de 32GB disponibles en el HS21, HS21 XM y LS21 • Solución más inteligente • Ratios de disponibilidad esperada son casi 4X los de los discos SAS convencionales • Dos discos de estado sólido de 16GB ocupan el espacio de una bahía de disco duro tradicional • 87% menos energía Menos energía, más ahorro *Source: Carnegie Mellon University Study, 2007 (http://www.usenix.org/events/fast07/tech/schroeder/schroeder_html/index.html)

  25. IBM BladeCenter – Right – I/O Fabric

  26. Más flexibilidad y libertad de elección en I/O Ethernet Fibre Channel InfiniBand Cisco 4X InfiniBand Voltaire 4X Pass Through Cisco Intelligent Ethernet Cisco Fiber Layer 2/3 Nortel Copper Layer 2/3 Nortel Fiber Layer 2/3 Nortel Layer 2/7 Nortel Layer 10Gb Uplink Nortel Layer 10Gb Server Connectivity Module Copper Pass-Thru Brocade 10 / 20-port QLogic 10 / 20-port Cisco 10 / 20-port McData 10 / 20-port Optical Pass-Thru Intelligent Pass-Thru Right sized for your needs • Simple pass-thru designs • Super low-cost, simple switches • Powerful, standard layer 2/3 offerings • Highly advanced layer 2/7 • High-performance 4Gb Fibre Channel • Industry’s only integrated full 10Gb Ethernet solution for blade servers OPEN

  27. Gran flexibilidad en el BCH More ports, more flexibility for more applications • Virtualization and multi-core environments require more connections • MSIM and BladeCenter H double the number of blade connections • Increase your Ethernet and Fibre Channel connections • New expansion cards allow up to 8 simultaneous connections per 30mm blade • Up to 10-12 I/O ports on double wide blade (60mm) • No need to qualify new switch modules • Supports most standard BladeCenter switches in new high-speed switch slots of BladeCenter H • Extreme performance with 10G Ethernet & 4x Infiniband CFFv Dual 4G Fibre Channel HCA Multi Switch Interconnect Module (MSIM) Dual Fibre Channel/Ethernet Expansion Card CFFv Dual 1G Ethernet Card OPEN

More Related