Generic VVER 1000 MWe. Loss of Feedwater at Full Power Loos of ofsite power – assumed Emergency FW 3&4 – disabled Steam bypass to condenser ( BRU -K ) – disabled. Initial conditins (steady-state). Reactor thermal power 3119 MW RPV pressure 15.3 9 M P a
E N D
Generic VVER 1000 MWe Loss of Feedwater at Full Power Loos of ofsite power – assumed Emergency FW 3&4 – disabled Steambypass to condenser (BRU-K) – disabled
Initial conditins (steady-state) • Reactor thermal power 3119 MW • RPVpressure 15.39 MPa • RPV coolant in/out temp. 291.6 / 324.6 degC • MCP flow 4147 kg/sec / loop • Feedwater flow 424.5 kg/sec / SG • Feedwater temp. 220 degC • Steam press. (sg dome) 6.145 MPa • SG water level 2.12 m • Pressurizer water level 8.88 m
Plots for the short time range0 – 1000 secTime of the FW loss: 100 sec
Plots for the long time range0 – 3600 secTime of the FW loss: 100 sec