160 likes | 457 Views
GS3055-I Installation Process. GS3055-I Overview. The GS3055-I is : A universal wireless alarm communicator that can be used as a backup or primary communicator
E N D
GS3055-I Overview • The GS3055-I is: • A universal wireless alarm communicator that can be used as a backup or primary communicator • A device which connects the alarm control panel to the GSM network and reports alarm signals directly to a monitoring central station receiver (Sur-Gard System III with a DRL3-IP line card or System II) • A digital transmitter which provides full reporting from any control panel that communicates using Contact ID format
GS3055-I Service Provider • Who is CONNECT 24? • CONNECT 24 is the GS3055-I service provider • CONNECT 24 provides the automated telephone activation system for the activation of GS3055-I units (GVRU, Voice Response Unit) • CONNECT 24 provides the web-user interface support for the programming of GS3055-I units(future use) • CONNECT 24 provides account administration, billing and rate plans to GS3055-I customers
GS3055-I Enrolment Steps In order to properly enrol a GS3055-I unit you must follow these steps: Important Note: Prior to installing a GS3055-I you must first become an authorized dealer. Please consult your central monitoring station for master reseller programs or visit www.connect24.comand complete the authorization form STEP 1 – Activate your SIM card with Connect 24* STEP 2 – Initialize the GS3055-I with Connect 24* STEP 3 – Determine best signal strength location STEP 4 - Connect the GS3055-I to the control panel STEP 5 - Program the control panel to use the GS3055-I STEP 6 – Test the GS3055-I * Note: GS3055-I unit must be powered down for STEPS 1 and 2
GS3055-I SIM Card Activation (GVRU) • Prior to installation, each SIM Card must be activated via the Connect 24 GVRU (1-866-910-3865, option [6]). Activations must be performed at least 24 hours before to installation (initialization) • The following information is required when activating a SIM Card: • Installer’s ID Number: Identifies each installer listed on the Dealer Enrolment Form • Installer’s PIN Number: Identifies each installer with a 4 digit PIN number • The SIM Card Number:(Subscriber Identity Module), 19-20 digits located on SIM Card Note:Only authorized dealers can activate a SIM Card with CONNECT 24
GS3055-I Initialization (GVRU) • GS3055-I initializations can be performed via the Connect 24 GVRU (1-866-910-3865, option [4]) • Enter the following information and options when initializing a unit: • Profile Number: Represents the Central Station Receiver IP address and Rate Plan • Installer’s ID Number: Identifies the installer listed on the Dealer Enrolment Form • Installer’s PIN Number: Identifies the installer • The Central Station Account Number: Represents the account number that will be transmitted to the Central Station Receiver • The SIM Card Number: (Subscriber Identity Module), 19-20 digits located on SIM Card • The DNIS Number: (Dialled Number Information Service), Check with your Central Station • 7. Test transmission selection: select the required test schedule (no test, daily, weekly or monthly) • Determine if GS3055-I unit is the primary or backup communicator: enable/disable TLM (telephone line monitor) option Note:Only authorized dealers can activate a SIM Card with CONNECT 24
GS3055-I Signal Strength Test • To test the signal strength of a GS3055-I: • Connect the antenna to the GS3055-I • Ensure that the SIM card is installed into the GS3055-I • Connect the battery to the GS3055-I • Signal strength levels: • LED#3 and LED#4 ON = Excellent Signal Strength • LED#4 ON = Good Strength • LED#4 Flashing = Poor Signal Strength • Both OFF = No signal Strength • Note: For proper installation, a GS3055-I must have Good or Excellent Signal Strength. If a poor strength is detected, the unit should be relocated or an antenna extension should be used LED# 3 LED #4
GS3055-I – Telephone Wiring (Back-up Mode) To Power Supply From RJ-31X Demarcation To Premise Telephones
GS3055-I Control Panel Programming The following control panel programming is required : • Telephone number * • Account number • Communications format – Contact ID • Reporting codes or select automatic reporting** • Communications enabled *If communicating only using the GS3055-I (no land-line), program any telephone number **If supported by the control panel
GS3055-I Testing • To test the GS3055-I, perform the following: • Disconnect the telephone line from the TIP and RING terminals on the GS3055-I • Wait for LED 2 (YELLOW) to turn ON (indicates that the unit is in GSM mode) • Force the control panel to transmit a signal (i.e. zone alarm, keypad alarm etc.) • Connect a handset to RING and TIP on the control panel to verify that the control panel is communicating
GS3055-I – Testing Diagram To Power Supply Connect the 12V/1.2AH Battery to the GS3055-I To Premise Telephones
GS3055-I Assistance Directory Connect 24 Phone Number: 1-888-955-5583 (Canada) 1-888-251-7458 (US) Fax: 1-877-224-3676 Website: www.connect24.com E-mail: customerservice@connect24.com GVRU Activation and Initialization: 1-866-910-3865 DSC Technical Support Phone Number: 1-800-387-3630 E-mail: tech@dsc.com Website: www.dsc.com
GS3055-I Questions?