1 / 16

Status report NIKHEF

Status report NIKHEF. NIKHEF Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA DAPNIA Maximilien Chefdeville Paul Colas Yannis Giomataris Arnaud Giganon Univ. Twente/Mesa+ Jurriaan Schmitz

alika-dyer
Download Presentation

Status report NIKHEF

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status report NIKHEF NIKHEF Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA DAPNIA Maximilien ChefdevillePaul Colas Yannis Giomataris Arnaud Giganon Univ. Twente/Mesa+ Jurriaan Schmitz CERN/Medipix Constm Eric Heijne Xavie Llopart Michael Campbell PhD student per 1/9/04 Thanks to: Wim Gotink Joop Rovenkamp TPC R&D phone/VRVS meeting 21/7/2004

  2. Detection of single electrons using MediPix2/Micromegas assembly as Direct Pixel Segmented Anode • Analysis of cosmic data 31/3-2/4 • Final draft of NIM paper ready http://www.nikhef.nl/~d90/tesla/letter3.pshttp://www.nikhef.nl/~d90/tesla/letter3.pdf • #pixels hit/mm track length = 1.83 • #clusters/mm track length = 0.52 • Single electron efficiency 0.9 • Moire effects: mismatch in pixel and hole pitch: 60/(60-55) = 12 pixels repetition

  3. He/Isobutane 80/20 Modified MediPix Sensitive area: 14 x 14 x 15 mm3 Drift direction: Vertical max = 15 mm

  4. He/Isobutane 80/20 Modified MediPix δ-ray?

  5. Peter Kluit: cluster & electron density versus MC of MIP cosmic rays: single electron efficiency > 0.90 AND: Good explanation for Moire effect: pitch Micromegas holes: 60 μm pitch MediPix pixels: 55 μm Periodic position of hole w.r.t. pixel: repeats after 12 pixels! Non Modified Modified

  6. Modified Non Modified InGrid: perfect alignment of pixels and grid holes! Small pad: small capacitance!

  7. InGrid Integrate GEM/Micromegas and pixel sensor ‘GEM’ ‘Micromegas’ By ‘wafer post processing’

  8. First InGrid expected in 2-3 weeks Wafer dia.: 100 mm 30 fields with variety of pillar geometry

  9. INGRID: some first trials Various pitches, shapes

  10. WSLC-Paris 2004: LC ready in 2015…, not known where….. • People with power and $: what is the relevance for LHC?! • So: • Other applications of TimePixGrid: • μ-TPC • upgrades of TPCs: STAR, ALICE • Transition Radiation Detectors • GOSSIP: tracker for intense radiation environment

  11. MIP Micromegas CMOS pixel array GOSSIP: Gas On Slimmed SIlicon Pixels MIP Cathode foil CMOS pixel chip Drift gap: 1 mm Max drift time: 10 ns

  12. Essentials of GOSSIP: • Generate charge signal in gas instead of Si (e-/ions versus e-/holes) • Amplify # electrons in gas (electron avalanche versus FET preamps) • Then: • No radiation damage in depletion layer or pixel preamp FETs • No power dissipation of preamp FETs • GOSSIP: 1 mm gas layer + 20 μm gain gap + CMOS (digital!) chip • After all: it is a TPC with 1 mm drift length (parallax!) Max. drift length: 1 mm Max. drift time: 10 ns Resolution: 0.1 mm  1 ns

  13. Efficiency Position resolution Rate effects Ageing Radiation hardness HV breakdowns Power dissipation Material budget More details in http://www.nikhef.nl/~d90/tesla/NIPHAD_GOSSIP.ppt

  14. Conference presentations: • LCWS Paris, April (Jan T.) • IPRD Siena, May (Harry v/d G.) • IWORID Glasgow, July (Alessandro F.) • VERTEX Como, September (Harry v/d G.) • IEEE Rome, October ( Harry v/d G. ?)

  15. Coming activities: • Cosmic trigger setup ready in few weeks • New Micromegas available very soon (PaulC.?) • New Medipix2 available • First Ingrid1 tests • Simulations • Longer term: • Ingrid2 together with MediPix • Development of Timepix1 (for TPC) and Timepix2 (for GOSSIP) CMOS chips