2009 IECC Energy Code Overview

2009 IECC Energy Code Overview. WV Building Energy Code.

alvaro
Download Presentation

2009 IECC Energy Code Overview

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2009 IECC Energy Code Overview

  2. WV Building Energy Code West Virginia's residential building code is mandatory statewide; however, adoption by jurisdictions is voluntary. The 2013 West Virginia Legislature passed and Governor Earl Tomblin signed into law a bill updating the state’s building energy code to follow the 2009 IECC for residential buildings. The West Virginia Fire Commission, which promulgates the state’s building energy code, set the effective date for the new residential code to become effective November 30, 2013.

  3. WV Building Energy Code Stakeholder Advisory Group: An informal partnership of stakeholders in W.Va.’s built community worked together to effect the adoption of the 2009 IECC, evidenced by a slightly later effective date for the code. Parties agreed to a later implementation date so that the WV Division of Energy could provide training on the new code to as many home builders as possible. This partnership was formalized at the “Next Steps” meeting on May 16, 2013, at the offices of the WV Division of Energy. Representatives from the home builders, code officials, architects and, importantly, realtors met to determine the next steps for continuing education, including CE credits for each industry, on the codes. Appraisers have since joined the effort.

  4. ACEEE 's 2012 State Scorecard Ranking for WV: 49 Prior to 11/30/2013 Post 11/30/2013 ACEEE 's 2012 State Scorecard Ranking for WV: 46

  5. US Climate Zones

  6. WV Climate Zones Climate Zone 4 Values • Ceiling R-value 38 • Wood Frame Wall R-value 13 • Mass Wall R-value5/10 • Floor R-value 19 • Basement Wall R-value10/13 • Slab R-value, Depth 10, 2 ft • Crawlspace Wall R-value 10/13 • Fenestration U-Factor 0.35 • Skylight U-Factor 0.60 • Glazed fenestration SHGCNR 4 5 4

  7. Notable Requirements in the 2009 IECC • Building envelope must be caulked and sealed • Slab-on-grade insulation is R-10 to a depth of 2 feet • Supply ducts in attic must be insulated to R-8. Return ducts in attics and all ducts in crawl spaces, unheated basements, garages and otherwise outside building envelope must be insulated to R-6. • All ducts must be sealed and either: • Verified by pressure testing – the duct system must be tested and the air leakage out of the ducts must be kept to an acceptable maximum level. 6CFM/100 SF. • Installed entirely with the building thermal envelope - testing is not required if all ducts are inside the building thermal envelope (for example, in heated basements) , though the ducts still have to be sealed. • 50% of the lighting in a building must be high-efficacy. CFLs qualify, standard incandescent bulbs do not.

  8. Cost Savings Relative to 2006 IECC Life Cycle Cost Savings ($) Simple Payback (years) 2009 IECC $ 1,996 5 $ 7,301 4.9 2012 IECC Life cycle cost is the primary measure by which DOE assesses the cost-effectiveness of the IECC. These savings assume that initial costs are mortgaged, that homeowners take advantage of the mortgage interest deductions and that long-lived efficiency measures retain a residual value after the 30 year analysis period.

  9. Thermal Envelope

  10. DIAGNOSTIC EQUIPMENT

  11. Diagnostic Equipment The Blower Door is a practical and effective way to test parts of the home’s air barrier to locate air leaks. The fan pressurizes/depressurizes the home to a standard pressure. Gauges then measure air leakage. Desired leakage is 4-5 ACH (Air Changes per Hour). Blower Door

  12. Diagnostic Equipment Duct leakage testers are actually small blower doors connected to the duct system of a home. They measure the severity of duct leakage and help to locate leaks. The average home has approx. 20-40% duct leakage. Desired leakage is 4% of SF of house. Duct Leakage Test

  13. Diagnostic Equipment Many energy auditors are now using infrared cameras to pinpoint air leakage areas in a home. IR cameras are not x-ray machines. They measure temperature differences. Many are sensitive enough to detect within .5° F or even less. Infrared Camera

  14. THERMAL IMAGES

  15. Thermal Images Missing insulation Lacking insulation

  16. Thermal Images Air Leakage through Receptacle Air Leakage through Can Light

  17. Thermal Images Air Leakage through Bath Exhaust Fan with Dysfunctioning Damper Air Leakage through Top Plate

  18. Thermal Images Air Leakage through Light Fixture Air Leakage through Attic Access Door