60 likes | 172 Views
Triple GEM Operation. RD51 Group Saha Institute of Nuclear Physics 14 February, 2014. Triple-GEM Connection. Cathode. 0.1M . 0.1M . 0.1M . 10M . 2.2nF. 2.2nF. Drift (3mm). 1.0M . HV. Filter. 10M . GEM1. Transfer 1 (1mm). 0.55M . 1.0M . GEM2. Transfer 2 (2mm).
E N D
Triple GEM Operation RD51 Group Saha Institute of Nuclear Physics 14 February, 2014
Triple-GEM Connection Cathode 0.1M 0.1M 0.1M 10M 2.2nF 2.2nF Drift (3mm) 1.0M HV Filter 10M GEM1 Transfer 1 (1mm) 0.55M 1.0M GEM2 Transfer 2 (2mm) 0.5M 10M 1.0M Induction (1mm) GEM3 10M 0.4375M Anode 1.0M 4 Readout Sectors Divider 13th RD51 Collaboration Meeting
Pulse Height Spectra for 4 Readout Sectors HV = 4450 V Without RC filter 13th RD51 Collaboration Meeting
Pulse Height Spectra For Different HV 4450 V 4550 V 4650 V 4750 V With RC filter 13th RD51 Collaboration Meeting
Gain Variation with High Voltage (before RC filter) • Assumed that the voltage divider configurations are same in both the cases ! • No idea whether the HV in CMSGEM is before or after the RC filter ! 13th RD51 Collaboration Meeting