1.83k likes | 5.18k Views
PVG and After Sales and Service. Agenda Index. PVG and After Sales and Service. After Sales and Service Technical information General guidelines in systems Trouble shooting Disassembly / assembly of valves. Valve. Proportional. Group. Output in KW. PVG and After Sales and Service.
E N D
Agenda Index PVG and After Sales and Service After Sales and Service • Technical information • General guidelines in systems • Trouble shooting • Disassembly / assembly of valves
Valve Proportional Group Output in KW PVG and After Sales and Service PVG32 PVG 32 280 bar*65 l/min 600 1988 = 32 KW 400 bar*130 l/min 600 2011 = 86 KW
Introduction to PVG Valves All families of valves PVG 20 PVG 100 PVG 120 PVG 32 PVG 16 PVG/HIC Hybrid solution PVX
BA PVG Product Roadmap Product Portfolio Valve portfolio 0-240Lpm, low to high performance, analog and digital. PVG 16
PVG32/100/120 Specifying a PVG • Customer can specify their own PVG Valve • Flexible modular design • Each specification sheet is unique • More than 100.000 customer valve variants • 1–12 sections PVG32 • Combination between PVG32 and PVG 120 is possible (4 section PVG 120 & 8 section PVG 32) • Combination between PVG32, PVG16 and PVG100
Know-How in Motion™ PVG 32 PVG modular build concept – all parts interchangeable PVMD/F/H/R covers PVS endplates App. 30 variants PVBS spools App. 680 variants PVE actuator App. 110 variants PVM handles App. 22 variants PVB work sections App. 75 variants PVP inlets App. 135 variants
PVG32/100/120 Specifying a PVG
PVG Identification PVG32 Module Information ( internal production.no) PVE Module Information Module Information Assembly Information
PVG 32 Assembly Identification PVG Identification Assigned Assembly /Group Number (today: 11xxxxxx no.) Relief Pressure Setting (bar) Build Center Code Bar code + Date Code / Build and Test Date 47
PVG 32 Module Identification PVG Identification 157B6200 4901B022550 157B5110 4901B032550 All PVB and PVP modules identified with Part Number and Date Code engraved on module “A” port side. Internal production.no engraved on “B port” side
PVG 32 Module Identification PVG Identification PVE Module 11095110 4901B022550 Voltage Rating 12VDC 157B4911 4901E03664 Part Number Date Code
157B5111 PVP PVG Identification P Pressure reduction valve Pp Pressure gauge (M) Pressure relief valve T T Pp LS connection P LS
157B6233 PVB PVG Identification LS pressure limiting valve Shock & suction valve T Tank (PVE) Pilot PVE Pp LS Expander Pp LS A/B Shuttlevalve P For Cleaning
PVG100 Assembly Identification ( label) PVG Identification
PVG100 module Identification PVG Identification PVT PVB PVP All PVB, PVP and PVTmodules produced in Easlyidentified with Part Number and Date Code engraved and labeled. Parts produced in Nordborg has no marking. ( project started)
PVG Identification PVG 120 AssemblyIdentification PVG 120 Identification label is locatatedon the PVP (inlet) modulewith; -code no. -Pressure. setting -date stamp
PVG Identification PVG 120 PVB Identification 2610 G6014 2610 G6014 2610 G6014 PVB code no. Last fourdigits PVB Date code
PVG Identification PVG 120 PVP and PVT Date code 1707 1707
PVG Identification PVG 120 PVB casting code; cannotbeused for identification 155G6302
PVBS Identification PVG Identification PVG 120 spool PVG 100 spool PVG 32 spool
PVBS Identification PVG Identification Flow from 65-240 l/min Flow from 40-240 l/min PVG 120 spool PVG 100 spool Flow from 5-130 l/min PVG 32 spool
PVBS Identification PVG 32 PVG Identification (157B)7004 Markings pre 1998 (157B)7004 (157B)7004 Today’s spool (155L)7354 110xxxxxx Relief grooves
Notch identification PVG Identification Open in neutral; i.e. for hydraulic motors Open in Neutral Closed in neutral; i.e. for cylinders Closed in neutral LS a/b Check valve LS a/b Check valve
Work Section OptionsPVB32 <-- WithoutLSA/B- ShuttleWith--> Check valve LSA/B- Shuttle valve LS Relief valve
PVBS Identification PVG 100 PVG Identification PVG 100 spool
PVBS Identification PVG 100 PVG Identification Closed Ported Cut LS Bleed Down Holes Open Ported, Restrictive Cut Balancing / Timing Grooves for P.O. Logic Part Number Date Code
PVBS Identification PVG 120 PVG Identification 6466 PVG 120 spool Last fourdigits of the code no. Eg 155G6466, datecode on opposite side
PVG Identification PVLP for PVG 32 and 100 Pressure range Tolerances 25 -> 80 bar +20 bar 85 -> 230 bar +23 bar 235 -> 350 bar +10% Suction Spring Work port pressure Tank pressure Shock Spring
PVLP Identification PVG 32 and PVG 100 PVG Identification Date stamp 2311 230 Pressure setting in Bar
PVLP Identification PVG 120 PVG Identification Work port pressure Tank pressure Suction Spring 250 Pressuresetting eg. 250 BAR
PVE Identification ASIC Electronic modules 2*Normally Open (NO) 2*Normally Closed (NC) Cover Base plate Aluminum block Coil packages Solenoid valves LVDT
PVE Identification • PVE Electrical / hydraulic data • ON / OFF 12/24 V/DC • Proportional 11-32 V/DC, Medium, High, Super • CAN – Bus • Float • Ramps • Hirschmann- , AMP-, Deutsch-Connector • Passive- , Aktive-Fault monitoring • -30° to +60°C Ambient-temp. • -30° to +90°C Oil-temp.
PVE Identification PVEO, on/off PVES, -H & -A Ratio-metric analogue w. spool feed back PVEP PWM controlled w. spool feed back PVED CAN controlled w. spool feed back
PVE Identification • Electrical connections
2008 • PVE Identification Elektronic 2/2 way valves Mainspool in PVG
PVE Identification Solenoid valve principle, type 1 • …used in: • PVEA / PVEA-DI
PVE Identification Solenoid valve principle, type 2 • …used in: • PVEO / PVEO-R • PVEM • PVEH / PVEH-DI • PVES
PVE Identification The Function 2013
2013 • PVE Identification
2013 • PVE Identification Fault monitoring description The input voltage is continuous monitored. The acceptable signal range is between 15% and 85% of the supply voltage. If Signal voltage goes outside of this range, the system will switch into an error state. Input signal monitoring If one of the wires to the LVDT sensor, or inside the sensor, is broken or shorted, the system will switch ínto an error state. Transducer supervision The spool position must always correspond to the position requested by the input signal. If the spool is 15% farther from neutral (providing more flow) than requested, the system detects an error and will switch into an error state. Supervision of the closed loop
PVE Identification 2013 Fault monitoring description Acceptable Working Signal range: Spool position error Supply voltage: signal range: Nominal 100 % 100 % 100 % 11-32 volts = 100 % 85 % 85 % 85 % 75 % 75 % Spool position > 15% ==> ERROR Working Input signal range 50 % 50 % 50 % 50 % + Deadband 7% _ Working range Input signal > 15% ==> ERROR Spool position 25 % 25 % 15 % 15 % 15 % 0 % 0 % 0 % 0 %
2013 • PVE Identification - 750 ms delay (PVEA) - 750 ms delay (PVEA) 500 ms delay (PVEH) 250 ms delay (PVEH) - Memory - No memory PVE Series 4 PVEH, PVEA, PVEP and PVES Faultmonitoring versions Active or Passive. Active version Passive version LED LED Input signal Input signal Error signal out Error signal out Fault mon. Fault mon. Transducer Transducer logic logic Closed loop Closed loop Solenoid valves continuously active with power on Solenoid Disable valves Error output state signal is available in the connector
2008 • PVE Identification PVE series 4 Visible Fault Indication in PVEA, PVEH and PVES Constant Green = OK Blinking Red = External failure (input signal) Constant Red = Internal failure
2008 • PVE Identification PVE4 performance
PVED-CC – PLUS+1 Service ToolIntroduction Introducing the PVED-CC PLUS+1 Service Tool! • Replaces current WebGPI PVED interface tool. • PVED - PC interface using CG 150. • Displays all PVED on bus togeter with PVED setting • Easy change of communication target • Easy data upload/download between file and PVED • OEM data and Spool data stored as XML files New
PVG 16/32/100/120 PVE / PVED Suggested Information http://www.sauer-danfoss.com
Valve Installation Considerations Valve Installation Considerations