An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Experimental Study of the BEPCⅡ Backgrounds JIN Da-Peng IHEP, Beijing, China Representing the Backgrounds Study Group May 11, 2007, BEPCⅡ IMAC Meeting

  2. Outline • Motivation • Radiation detectors arrangement • Preliminary results • Next to do

  3. Motivation 1. Take means to protect the detectors from being damaged BEPCⅡis going well 2. Provide good environment for data taking

  4. Radiation Detectors Arrangement

  5. Magnified View On Mar. 27, 2007, 2# was moved to 5# e- Beam Fork Pipe Both Beams

  6. Detectors in the right places

  7. Parameters of theRadiation Detectors • PIN Diodes • 0.25nA/mrad·s-1 • Damage: 1~10nA/krad • Temp Dep: 1.11times/oC • Accuracy: ~5mrad/s • RadFETs • Range: 20,000rad • Accuracy: 1.5rad • Freq: 10min

  8. Preliminary Results 1#, 2#, 3#, 4# : 75cm from the IP; 6# : 3.31m from the IP. 160nA 80nA

  9. Preliminary Results 5# : 2.22m from the IP. 3000nA More than 1000nA

  10. Preliminary Results 5# detector suffers much more radiation doses than the others, which is more than one fold. Dominated doses for 5# detector are from the electron beam. 1#, 2#, 3#, 4# : 75cm from the IP; (Both beams) 6# : 3.31m from the IP; (Upper stream of e-) 5# : 2.22m from the IP. (Upper stream of e-)

  11. Preliminary Results Electron Beam Tuning 1#, 2#, 3#, 4# : 75cm from the IP; 6# : 3.31m from the IP.

  12. Preliminary Results Electron Beam Tuning 5# : 2.22m from the IP.

  13. Preliminary Results Electron Beam Tuning Dose rates during injections are much higher than steady runs for each detector.

  14. Preliminary Results Positron Beam Tuning 1#, 2#, 3#, 4# : 75cm from the IP; 6# : 3.31m from the IP.

  15. Preliminary Results Positron Beam Tuning 5# : 2.22m from the IP.

  16. Preliminary Results Positron Beam Tuning 5# and 6# detectors suffers less doses. Vertical detectors suffers less doses. For the horizontal detectors 1# and 3#, Outer Ring(1#) .GT. Inner Ring(3#)

  17. Preliminary Results Double Beam Tuning 2# moved to 5#.

  18. Preliminary Results Double Beam Tuning 2# moved to 5#.

  19. Preliminary Results Double Beam Tuning 2# moved to 5#. Really, Dose Rate at the fork pipe (about 2.2m from the IP) is much higher.

  20. Preliminary Results Int. Dose to the CsI Crystals 30cm 40cm 50cm 60cm

  21. Preliminary Results Int. Dose to the CsI Crystals 40cm 50cm 60cm

  22. Preliminary Results Int. Dose to the CsI Crystals The maximum Int. dose at the position of the inner most CsI crystals is about 10rads/day, which is about 10 times that of the design value. Injections bring much more doses. The total Int. dose from the electron beam is higher than that from the positron beam.

  23. Preliminary Results Int. Dose at the fork pipe

  24. Preliminary Results Int. Dose at the fork pipe In the previous measurement, the Int. dose is .GT. 3000rads/day, which is mainly due to e- injections. In some cases, one turn injections can bring hundrends to one thousand rads Int. doses.

  25. Preliminary Results Beam Loss Monitors No. 48 No. 72 IP e- e+ BLMs are sensitive with charged particles

  26. Preliminary Results Beam Loss Monitors

  27. Preliminary Results Beam Loss Monitors

  28. Preliminary Results Beam Loss Monitors

  29. Preliminary Results Beam Loss Monitors

  30. Why so high dose? • The accelerator needs to be well tuned, since we have just started. • In the currently used vacuum chambers, the radius near the fork pipe is smaller than the design values and makes here the bottleneck of the storage ring. • Collimators not installed.

  31. Next to do • Further understand the results from the PIN Diodes, FETs and BLMs; • Deal with the backgrounds seriously and push ahead the manufacture and installation of the collimators; • Your suggestions??? Thanks!