150 likes | 295 Views
SESSION III STRUCTURAL SUPPORT & SEISMIC APPLICATIONS IWM 2002 MAY 29 – JUNE 1, 2002. HEWLETT PACKARD BUILDING 5 SEISMIC UPGRADE CORVALLIS, OREGON, USA TOM A. ARMOUR, P.E. PROJECT SYNOPSIS “Foundation Design & Construction”. Voluntary Seismic Upgrade Program Braced Frame Retrofit Scheme
E N D
SESSION III STRUCTURAL SUPPORT & SEISMIC APPLICATIONS IWM 2002 MAY 29 – JUNE 1, 2002 HEWLETT PACKARD BUILDING 5 SEISMIC UPGRADECORVALLIS, OREGON, USATOM A. ARMOUR, P.E.
PROJECT SYNOPSIS“Foundation Design & Construction” • Voluntary Seismic Upgrade Program • Braced Frame Retrofit Scheme • Foundation Support Required • Vibration and Noise Sensitivity • Access Issues • Strict Pile Deflection Criteria • Micropiles Most Feasible Option
SUBSURFACE PROFILE“Ground Conditions” Soft Clayey Silt (ML) 8 m Medium Dense Sands (SP) 3 m Very Dense Sandy Gravels (GP)
DESIGN SUMMARY“Foundation Support System” • Three Micropile Types • CASE 1 Type B micropiles • 135 total micropiles • Seismic Design Loads • Compression = 540 kN – 720 kN • Tension = 450 kN – 540 kN • Deflection Criteria • Verif. = 6.4 mm @ 900 kN Test Load (1.67 SDL) • Proof = 3.8 mm @ 810 kN Test Load (1.5 SDL) • New and Existing Pile Footings • 3 meters to Unlimited Headroom Access • Pile Load Test Program • One Each Verification Test to 200% SDL on Non-Production Piles • 5% Proof Tests on Production Piles
10 m Casing 140 mm to 178 mm x 10.5 mm to 16 mm wall casing Centralizer Med. Dense Sands Plunge Length Bond Zone 15 m Reinforcing Bar 50 mm & 63,5 mm Neat Cement Grout TYPICAL PILE DETAIL“H.P. Building 5”
MICROPILE MATERIALS“H.P. Building 5” • Permanent Steel Pipe • API 5CT & ASTM A252 • 550 MPa yield • Flush joint threads • Steel Reinforcement • ASTM A615 • Mechanical coupling • Cement Grout • Neat cement – ASTM C150 • W/C ratio of 0.45 • 27,6 MPa (min)
CONCLUSIONS“H.P. Building 5 Micropiles” • Another successful application of micropile use for seismic retrofit of sensitive buildings. • H.P. continuing to use micropiles on other building retrofits.