1 / 15

DJC Testing at LaTech: Update

DJC Testing at LaTech: Update. Quality Control Tests of DJC’s. Continuity and shorts test Resistance testing High voltage standoff testing. LaTech Testing Crew: Moreshwar Dhole Qun Yu Matthew Bellot Henry Hollins. Since our last report.

amy-oliver
Download Presentation

DJC Testing at LaTech: Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DJC Testing at LaTech:Update Qun Yu / Moreshwar Dhole Louisiana Tech University

  2. Quality Control Tests of DJC’s • Continuity and shorts test • Resistance testing • High voltage standoff testing. LaTech Testing Crew: Moreshwar Dhole Qun Yu Matthew Bellot Henry Hollins Qun Yu / Moreshwar Dhole Louisiana Tech University

  3. Since our last report • Updated and improved our database to reflect changes suggested last time and to include results of recent testing • Received 168 50cm-test cables from Century • Commenced affixing backings to cables as per procedure from Jim Fast • In parallel, ~80 of these have been tested Qun Yu / Moreshwar Dhole Louisiana Tech University

  4. On the following slide are sample data from SHEET 1 of the DJC database (http://caps.phys.latech.edu/~greenw/run2b/run2b_page.html) Qun Yu / Moreshwar Dhole Louisiana Tech University

  5. Qun Yu / Moreshwar Dhole Louisiana Tech University

  6. Also on the DJC database spreadsheet is SHEET 2 which has resistance measurements, mean resistances and standard deviations. Part of this sheet is on the next slide.. Qun Yu / Moreshwar Dhole Louisiana Tech University

  7. Qun Yu / Moreshwar Dhole Louisiana Tech University

  8. Some Observations… • We have tested ~125 Century cables. • Of these, ~ 10 cables have some type of defect- shorts between lines, discontinuity, or high resistance. Shorts are the most common of these. Qun Yu / Moreshwar Dhole Louisiana Tech University

  9. END OF REPORT Qun Yu / Moreshwar Dhole Louisiana Tech University

  10. EXTRA SLIDES Qun Yu / Moreshwar Dhole Louisiana Tech University

  11. Digital Jumper Cable Readout Setup: Qun Yu / Moreshwar Dhole Louisiana Tech University

  12. 3) High Voltage Standoff Test: • The purpose of this test is to check whether there is any short or current leakage (Arcing) between HV (High Voltage) Cu trace and other adjacent Cu traces. • For this testing here at LaTech we developed our own High Voltage Testing Jig and it is working fine. • This High Voltage Testing Jig allows us to test 10 cables at a time for overnight. Qun Yu / Moreshwar Dhole Louisiana Tech University

  13. Test procedure: • Continuity: two multimeter probes are connected to both ends of the line in a given cable, if the line is good, there will be “beep” from multimeter. • Short circuit tests: each line is tested against its nearest neighbor. Qun Yu / Moreshwar Dhole Louisiana Tech University

  14. High Voltage Test Schematic Qun Yu / Moreshwar Dhole Louisiana Tech University

  15. Complete Test Setup: Qun Yu / Moreshwar Dhole Louisiana Tech University