An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Development of Silicon Strip Detector for the measurement of Ξ-atom X-rays Hitoshi Sugimura Kyoto University (For E03 collaboration)

  2. Collaborators • SNU Kiyoshi Tanida RyutaKiuchi Joo Chang Woo • JAEA Ken’ichi Imai Hiroyuki Sako Susumu Sato • KyotoU Hitoshi Sugimura Satoshi Adachi Hidemitsu Asano • RCNP TomoakiHotta

  3. J-PARC E03 experiment Strong Interaction makes Energy Shift K+ K- Fe p 1.8GeV/c Ξ- Ξ- Fe Fe X-ray We detect X-ray from Ξ-atom by using Ge-detector for the first time. Energy shift provides information of ΞN interaction. Ge-Detector

  4. J-PARC E03 experiment Strong Interaction makes Energy Shift K+ K- Fe p 1.8GeV/c Ξ- Ξ- Fe Fe 1-step ,We detect X-ray by using Ge-detector. How to detect X-ray from xi atom is first challenge And 2-step make sure that how much energy shift. Make us information to ΞA interaction X-ray Ge-Detector Expected Energy Shift (Simulation)

  5. Detector Set up KURAMA magnet Hyperball-J K- target K+ SSD K- Target SSD measures Ξtrack and dE/dx to select slow Ξ so that better S/N ratio will be obtained for stopping Ξ. SSD

  6. Silicon Strip Detector (SSD) • Thickness ~300um • Effective area 6cmx6cm • Pitch 80um x 768 strips • Read out chip : APV25 • 128ch readout /1chip • Shaping time 50nsec • Serial Data Transfer • Radiation tolerancechecked up to 3x1014protons /cm2 • At 108Hz beam, efficiency is accomplished up to 96%

  7. Beam Test at J-PARC K1.8 beamline K Target (inside of cryostat) SSD SSD SSD 計12面  768ch

  8. Wave analysis

  9. Time resolution and S/N • Reconstruct Hit Timing σ=3.61ns If 107Hz beam , probability accidental hit is 13.6% Good enough to identify ghost tracks. σ=3.61ns • Reconstruct pulse height by wave form analysis. time MIP signal Noise level S/N= We have achieved SNR>10 =17.0 S/N

  10. Summary • SSD has been developed for E03 which detect X-ray from Xi atom for the first time . • SSD has been tested at J-PARC K1.8 beamline. • We have obtained S/N = 17 and time resolution is 3.61ns which is sufficient for E03 experiment.

  11. Back up

  12. a new Ge detector array Hyperball-J Hyperball2 ( ε ~4 % for 1 MeV) can not be used @J-PARC due to high count rate & radiation damage → Need new Ge detector array Lower half of Hyperball-J PWO counter Ge detector Target • Features • Radiation-hard Ge detector • →Mechanical cooling • Fast background suppressor • → PWO counter • Pulse-shape readout and analysis • Adjustable detector geometry • Large photo-peak efficiency • → ε~6.1 % @1 MeV with 32 Ge detectors • Remotely controlled and monitored Pulse-tube cooler

  13. K1.8 beamline for KURAMA setup