San Jose, 03.10.2005 Seminario v.SP0509

Uni Gear tipo ZS2 Presentación del producto. San Jose, 03.10.2005 Seminario v.SP0509. UniGear tipo ZS2. Celal Sendil Product & Marketing Manager UniGear tipo ZS2 ABB Elektrik Sanayi A.S. Fábrica de UniGear tipo ZS2. Localizada en Estambul, Turquía

andres
Download Presentation

San Jose, 03.10.2005 Seminario v.SP0509

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UniGear tipo ZS2Presentación del producto San Jose, 03.10.2005 Seminario v.SP0509

  2. UniGear tipo ZS2 Celal Sendil Product & Marketing Manager UniGear tipo ZS2 ABB Elektrik Sanayi A.S.

  3. Fábrica de UniGear tipo ZS2 • Localizada en Estambul, Turquía • Fábrica conresponsabilidad global (GFFF) del producto UniGeartipo ZS2 • con diseño propio electronico/mecanico, fabricación e instalaciones de (R&D) Investigacion y Desarrollo • Facilidad de producción de 6500 sqm • fabricación de acero del CNC • fabricación de cobre • facilidad de capa del polvo • Ensamblado y test • Certificacion ISO 9001 Y ISO 14001 • Capacidad de Entrega anual de 2000 celdas por año

  4. UniGear tipo ZS2 - Definición 36kV Celdas blindadas, aisladas en aire, a prueba de arco interno, para distribución Air insulated, metal-clad, internal arc-proof, type tested, compact, Medium Voltage Switchgear for power distribution systems below 36kV rated voltage level Definición según el nuevo IEC62271-200 Clase de la partición : PM Pérdida de categoría de la continuidad del servicio : LSC2B Clasificación interna del arco : IAC AF-LR

  5. UniGear tipo ZS2 - Posicion en el portafolio WEB page view from www.abb.com

  6. UniGear tipo ZS2 - Características eléctricas Normas de construcción yensayoIECTensión nominal [kV] 36 Tensión soportada a los impulsos [kV] 70/170 Corriente nominal de las barras [A] max 2500 Corriente térmica nominal de los [A] 1250 interruptores 1600 2000 2500 Corriente asignada de breve duración [kA] 25/3s - 31.5/1s* Corriente de cresta [kA] 63-80 Corriente con capacidad de soportar el arco interno [kA] 25/1s Los funcionamientos normales del servicio están garantizados bajo las siguientes condiciones: Temperatura ambiente mínima- 5 °C Temperatura ambiente máxima+ 40 °C 95 % Atmósfera no contaminada normal * Earthing switch making capacity is upto 25kA

  7. UniGear tipo ZS2 -Tabla de selección de la celda

  8. 4 Compartimento de baja tension 2 Compartimento de barras 1 Compartimento de interruptor 3 Compartimento de cable 5 Ducto de arco (expansion de gases) 7 Transformadores de tension 8 Seccionador de puesta al tierra 6 Transformadores de corriente UniGear tipo ZS2 - Construcción interna

  9. UniGear tipo ZS2 - Tipos estándares de la celda • Hay dos tipos de construcción estándar del panel • La versión requerida correcta será seleccionada usando la "tabla de la selección" en catálogo 1000 mm wide version 1200 mm wide version

  10. UniGear tipo ZS2 - Tipos estándares de la celda Duplex version Typical DIF (Incoming/outgoing feeder) panel sectional drawing Width : 1000 mm Depth : 3820 mm Height : 2161 mm (2662 mm with gus duct)

  11. UniGear tipo ZS2 - Características principales

  12. 1000 mm UniGear tipo ZS2 - Características principales Dimensiones compactas • Versión de 1000 milímetros de amplitud, hasta la corriente clasificada de 1600A. • Posibilidad de instalacıon contra la pared con acceso frontal a todos los compartimentos. Comparacion de dimensiones con los productos similares en el mercado Una de las celdas mas compactas en 36kV AIS en el mundo !

  13. UniGear tipo ZS2 - Características principales Continuidad de seguridad máxima del servicio! • Diseño del Metal Clad • Compartimientos separados y segregados con particiones metálicas conectadas a tierra

  14. 35ms 500ms UniGear tipo ZS2 - Características principales Interna del arco What is happening in 500ms ?

  15. UniGear tipo ZS2 - Características principales Confiable ! • Completamente tipo probado • Proteccion interna delantera, trasera y lateral de arco; seguridad máxima para los operadores Lanzamiento de gases calientes de cada compartimiento en caso de avería interna del arco Protección Posterior Protección Delantera Protección Lateral

  16. UniGear tipo ZS2 - Características principales

  17. UniGear tipo ZS2 - Características principales Videos de la prueba interna del arco Compartimento de interruptor Compartimento de cable Compartimento de barras

  18. UniGear tipo ZS2 - Características principales Fácil instalación y mantenimiento! • Diferentes accesos para el mantenimiento e instalación 2 Acceso al compartimiento de barras 1- Desde la parte posterior 2- Desde la parte superior Acceso al Compartimento de cable 1- Desde la parte posterior 2- Desde la parte delantera, desde el compartimento de CB 3- Desde la parte frontal, o de la cubierta inferior 1 2 1 3

  19. UniGear tipo ZS2 - Características principales Vida larga, diseño moderno! • Hoja de acero galvanizada u opcionalmente hoja de acero de pregalvanized para condiciones ambientales más resistentes • Diseño de laminas apernadas

  20. UniGear tipo ZS2 - Compartimento de barras • All busbars are round shapeheat shrink material insulated copper • No supportive insulators are used for busbar system. All are supported by bushings • Busbars bolted together and connection points are insulated with re-usable polycarbonate T-boots which can be easily installed after the connection is made • Accessible from top and rear

  21. UniGear tipo ZS2 - Compartimento de cable • Tubular insulated busbars • Cable connection points do not require any insulation. Distance between phases and phase to earth are standard 36kV air insulation distance • Designed for standard AIS cable terminations. No need for special kits. • Single or three core cable connection possibility upto 4 x 630 mm2 • Accessible from front , rear and sides* * Solution innovada! Durante las primeras instalaciones en el campo, la conexión de cables puede ser hecha fácilmente por el lado derecho

  22. UniGear tipo ZS2 - Componentes • Circuit Breakers • Earting switch • Protection, control and metering equipment • Instrument transformers • Other small electrical equipment

  23. Polo sellado de por vida ! UniGear tipo ZS2 - Componentes Interruptores en SF6 HD4 • Serie SF6 común para la División de M.T. de ABB • Utilización de la tecnología más avanzada de corte en SF6 • Técnica de extinción extremadamente suave • Polos sellados de por vida • Dispositivo de señalización de presión de gas, bajo demanda • Construcción simple y fiable • Reducción del número y tipo de repuestos • Un único mando para toda la serie • Gama completa de accesorios de fácil colocación La primera serie de M.T. basada en las probadas ven- tajas de la “auto-compresión” de SF6 en los ya conoci-dos interruptores automáticos de A.T., ensayados y usados en la mayoría de paises industrializados.

  24. UniGear tipo ZS2 - Componentes Seccionador de puesta al tierra • ABB ST-US36 type • Class E1 • Making capacity • Optional key-locks and padlocks • Visual inspection of earthing switch movement is possible from the front of the panel through dedicated window

  25. UniGear tipo ZS2 - Componentes Transformadores de corriente Transformadores de tension • No special transformer design is needed • CTs are block type, dimensions are according to DIN standards • Core CTs can be applicable • Withdrawable of fixed type VTs • Primary fused or non-fused

  26. UniGear tipo ZS2 - Componentes Proteccion, Medida y Mando • Variety of applications avaliable from most sophisticated systems to simple conventional systems depending on the customer request and project requirement • Possible to use multi-functional intelligent systems which cover all the needs regarding below functions • Measurement • Control • Signaling • Interlock • Automation • Communication

  27. UniGear tipo ZS2 - Configuraciones de la celda • Aplicaciones con Simple/Unico Barra • IF Llegada/Salida • BT Acoplador • R Subida • M Mediciones • IFD Llegada/Salida Directa • IFDM Llegada/Salida Directa con Mediciones • Aplicaciones con Doble Barras • DIF Duplex Llegada/Salida • DIFD Duplex Llegada/Salida Directa • DBTDuplex Acoplador y Subida • DMDuplex Mediciones

  28. UniGear tipo ZS2 - Tipos estándares de la celda • IFLlegada/Salida • BT&R Acoplador & Subida • M Mediciones • IFDM Llegada/Salida Directa con Mediciones • IFD Llegada/Salida Directa

  29. UniGear tipo ZS2 - Diseños de la variación • Ademas de los tipos estándares, diseños con variaciónesestan disponibles a su requerimiento. • Dependiendo de los requisitos específicos de cada proyecto, estudios de disenos para cada ordenpueden también ser requeridos, además de tipos disponibles (estándar o variación)de la celda Barra superior entrante Conexión de cable superior CTs on main busbar

  30. UniGear tipo ZS2 - Tipos estándares de la celda • Aplicaciones de Doble Barras

  31. UniGear tipo ZS2 -Referencias en el mundo • Iceland • Italy • Portugal • Russia • Spain • Sweden • Turkey • Turkmenistan • Serbia • Algeria • Angola • Burkino Faso • Equatorial Guinea • Mali • Mozambique • Niger • Nigeria • Senegal • Seychelles • South Africa • Sudan • Tanzania • Yemen • Australia • Fiji • Indonesia • Malaysia • New Zealand • Phillipines • Sri Lanka • Thailand • Vietnam En 44 paises • Egypt • Iran • Iraq • Jordan • Libya • Qatar • Saudi Arabia • United Arab Emirates • Argentina • Brazil • Colombia • Uruguay

More Related