ANALYST 3Q – Power Quality Analyser Functions – User Interface

ANALYST 3Q – Power Quality Analyser Functions – User Interface. Control Elements. Cursor control Save screen-shots, confirm entries Call menus, next level. Measurement start/stop Toggle measurement/ recording mode Activate CURSOR Display-backlight ON/OFF.

angeni
Download Presentation

ANALYST 3Q – Power Quality Analyser Functions – User Interface

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ANALYST 3Q – Power Quality Analyser Functions – User Interface

  2. Control Elements Cursor control Save screen-shots, confirm entries Call menus, next level Measurement start/stop Toggle measurement/ recording mode Activate CURSOR Display-backlight ON/OFF Rotary switch for selection of measurement function

  3. User Interface – SETUP • Use menus (button Menu/Esc) for settings: • Recordings - Averagingtime (recording period), threshold for events (dips, swells) • Memory - recall/delete screens • Display contrast • Instrument-SETUP - Ratios for CTs/PTs • info about instrument, backlight • Mains system - Star/delta, nominal voltage, frequency • Date/time • Language - German, English, French, Spanish, Italian

  4. User Interface – SETUP Examples:

  5. Accumulators  Mains operation User Interface – Display-Symbols Power supply Measurement functionDate / time Status Measure Record Change with: RECORD SAVE Measurement pause Recording pause Activate with: HOLD RUN Menu On/off with: MENU ESC Display recorded data

  6. User Interface – Function Selection • Easy operation: • Select measuring function with rotary switch • Connect test leads • Read off test results

  7. PQ – Power Quality • Normalised bar diagram for actual voltage quality parameters: • Voltage variations • Events • Harmonics • Flicker • Unbalance • Mains frequency • Quick View – instant display • EN50160 – with 10 minute intervals

  8. PQ – Power Quality • One bar for each phase L1, L2, L3 • Bars are normalised to appropriate limit – assessment of power quality at once • Adjustable limits (SETUP) • HOLD/RUN – • Freezes actual display • SAVE/ENTER • Saves screen shot to internal memory

  9. Digital Display of U, I, F • Digital display of RMS values of : • voltage U • current I • mains frequency F • U, I of each phase L1, L2, L3 additionally • maximum- and minimum value • HOLD/RUN freezes the actual display • SAVE/ENTER saves screen shot to internal memory

  10. Digital Display of U, I, F Recording of RMS values versus time (recorder mode) Configuration of recorder mode via SETUP RECORD/MEASURE toggles between recording and measurement mode Precise evaluation of time diagrams with cursor in HOLD-mode

  11. Waveforms • Oscilloscope diagram of the waveform of current and voltage of each phase: • Voltage U of L1, L2, L3 • Current I of L1, L2, L3 • over one mains period • Digital display of range and mains frequency • HOLD/RUN freezes actual display • SAVE/ENTER saves screen shot to internal memory

  12. Harmonics • Bar type diagram of the harmonics of the three phases: • Voltage H1- H40 • Current H1-H40 • Digital display of • THD, rms values of mains voltages and harmonics, percentage • HOLD/RUN freezes actual display, evaluation of harmonics with cursor in HOLD-mode • SAVE/ENTER saves screen shot to internal memory

  13. W - Power • Digital display of: • active power P, Ptot • apparent power S • reactive power Q • distortion power D • power factor PF, capacitive/inductive • voltage U • current I • mains frequency

  14. W - Power HOLD/RUN freezes actual display SAVE/ENTER saves screen shot to internal memory RECORD/MEASURE activates recorder mode with adjustable averaging time/recording period, data analysis with cursor in HOLD-mode

  15. Unbalance • Representation of phase voltages in a vector diagram : • voltage • Phase angle • Digital display of • RMS value of UL1, UL2, UL3 • phase angle • HOLD/RUN freezes the actual display • SAVE/ENTER saves screen shot to internal memory

  16. Events • Recording of voltage-time diagrams of the phase where the event occurred: • voltage dip • voltage swell • voltage interruption • MENU/ESC: Define thresholds • HOLD/RUN freezes actual display, start neww measurement • SAVE/ENTER saves screen shot to internal memory • Browsing of events on screen

  17. Flicker – Fl, Pst, Plt • Display of flicker intensity of L1, L2, L3: • Instant value Fl • Short time flicker Pst • (10min-average values) • Long time flicker Plt • (2 hours = 12x10min-average values) • Minimum-, maximum-values • Time diagrams (recorder mode)

  18. Flicker – Fl, Pst, Plt • HOLD/RUN freezes actual display, starts a new evaluation • SAVE/ENTER saves screen shot to internal memory • RECORD/MEASURE activates recorder mode – • 2 display modes: • Fl and Pst or • Fl and Plt • Data analysis with cursor in HOLD-mode