130 likes | 424 Views
Delta AC Motor Drive 2009. AMD Product Line-up. High-End System. VFD-CH. Premium Drive (built-in system controller). 150% FOC. G7. VFD-E. SVC. Industrial SVC V/Hz. V/F. F7+. VFD-EL. VFD-C. Standard. 120~150% FOC. VFD-VE. VT/CT FOC. Machine Tool. VFD-CF. 120% SVC.
E N D
Delta AC Motor Drive 2009
AMD Product Line-up High-End System VFD-CH Premium Drive (built-in system controller) 150% FOC G7 VFD-E SVC Industrial SVC V/Hz V/F F7+ VFD-EL VFD-C Standard 120~150% FOC VFD-VE VT/CT FOC Machine Tool VFD-CF 120% SVC Fan Pump/HVAC E7 VFD-B SVC General Purpose Industrial VFD-F SVC VFD-M VFD-L1 Especially for Gearless Elevator design VFD-S PM/IM VFD-VL VFD-L2 3 5 7.5 10 30 420 500HP 25W 100W 200W 1HP 2HP 100 300
AMD Product Positioning Market Application Variable Torque General Purpose Industrial Machine Torque Control Servo-Like EL Low Cost S/M E F B Versatility Flexibility CF VE VL C CH FOC vector Actual Application FAN PUMP HAVC Various Application Extruder Sectional Mixer Elevator Hoist Winder Unwind Helper Positioning Power Amplifier
AMD Product Roadmap Premium Drive VFD-CH (~420HP) 200 500 Standard Drive (+AFE) VFD-C (1~500Hp) VFD-VE VL 200 500 Fan & Pump VFD-CF (1~500Hp) Performance/ Functionality Gen IV (IPM) Micro & Nano Configurable Drive VFD-X (¼ ~30Hp) Frame D ~30Hp Ver. 2 Micro Drive(IP20) VFD-E (¼ ~15Hp) Nano ¼~5Hp VFD-EL ‘05 ‘06 ‘07 ‘08 ‘09 ‘10 ‘11 ‘12 Year
VFD-C FOC IM/PM DRIVE Main Specification • Sensorless Torque Control • PLC and CanOpen built-in, Position / Speed / Torque Servo-like Motor control • Dual rating (CT/VT), Integrated EMI filter (low HP) • RF Filter (high HP) and Side by side installation (low HP). • 4.Multi Encoder feedback (ABZ、SIN/COS encoder) • 5.Various communication accessories, • 6.Various I/O cards.
FocusedApplications FAN Paper CNC Hoist S & P Speed Torque H Torque PUMP Print Rubber Crane Speed H Torque S & P Textile Conveyor Extruder Elevator S & P Speed Speed Speed H Torque
VFD-CF FAN & PUMP Drives Main Specification • V/F & Sensorless Vector control • Integrated RF filter, Hall effect current sensing • Short-term constant torque output • Multi-motor application • Various communication accessories • Various extension I/O cards. • HVAC application
Purpose and Main Applications • HVAC system including typical adjustable frequency drive applications. • Chiller • Speed control of the chiller compressor is a special application undertaken only with close coordination between the drive and chiller manufacturers. • Cooling Tower • The cooling tower fan speed control is typically based on the water temperature at the discharge point. • Chilled Water Pump • The chilled water pump speed control is typically based on the differential pressure across the cooling coil that is located farthest from the chiller or the most distant significant load. • Air Handling Units (AHU) • The AHU fan speed control is typically based on the pressure in the air duct.