1 / 12

Cycle 23 GLEs with ESPs

Cycle 23 GLEs with ESPs. Allan J. Tylka 11 February 2009. 4 - 8 November 2001. This event erupts from a source region near central meridian. It is not only a GLE, but also has a clear increase in intensity associated with the shock’s arrival at Earth.

anja
Download Presentation

Cycle 23 GLEs with ESPs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cycle 23 GLEs with ESPs Allan J. Tylka 11 February 2009

  2. 4 - 8 November 2001 • This event erupts from a source region near central meridian. • It is not only a GLE, but also has a clear increase in intensity associated with the shock’s arrival at Earth. • We are generally unable to track the neutron monitor response through the shock (large geomagnetic disturbances, etc.) • We therefore break the spectral analysis into two parts, each of which we fit with a Band function. • the “GLE” (the first 10 hours in this event, in which we have both satellite and NM data) and • the “ESP” (the rest of the event, based solely on GOES MEPAD+HEPAD).

  3. 4 - 8 November 2001 “GLE” “ESP” The “GLE” produces most of the fluence above ~1 GV, while the ESP dominates at lower rigidities.For dose-depth calculations, both parts should be included.

  4. Another Example: 14 - 18 July 2000 In this event, the ESP associated increase is not as large as in the previous example.

  5. 14 – 18 July 2000 “GLE” “ESP”

  6. Another Example: 28 – 29 October 2003 (The increase at ~21 UT on 29 October is the start of another GLE.)

  7. 28- 29 October 2003 “GLE” “ESP”

  8. Another Example: 24 -27 August 1998 This is one of the smallest GLEs of Cycle 23. We were unable to derive spectra from the NM data. Spectra are based solely on GOES MEPAD+HEPAD.

  9. 24- 27 August 1998 “GLE” “ESP”

  10. Band-Fit Parameters for the GLE-Associated ESPs of Cycle 23(Preliminary Results)

  11. How well do our Band fits reproduce the data? • Compare Band fits for ESPs to GOES/MEPAD datapoints at >10, >30, >50, >60, >100 MeV. • Calculate fractional residual: (Data-Fit)/Data • Mean Residual ~ 4% • RMS Width of Distribution of Residuals ~ 25 % (compared to 10% for GLEs). • This is a much wider distribution of residuals, probably because we do not have NM measurements to aide in the determination of the spectrum beyond 100 MeV. • Are these fits nevertheless adequate for dose calculations?

  12. How well do Exponentials reproduce the data? • Exponential fits did not use the GOES/MEPAD datapoint at 10 MeV in order to optimize the fit accuracy at above 30 MeV, which is more relevant threshold for many radiation hazards. • Mean Residual ~ 4%, same as with the Band fit • RMS Width of Distribution of Residuals ~12%, better than the Band fits’ ~25% • Since the exponential fits are constrained only by measurements in a limited energy (30-100 MeV), they do a better job than the Band fit at these energies. But the exponentials still seriously underestimate higher energies.

More Related