Chillgard ® RT Refrigerant Monitors

Chillgard ® RT Refrigerant Monitors. AGENDA. Why Monitor Refrigerants? Photoacoustic Infrared Detection Chillgard RT Features and Benefits BACnet Capabilities Summary. Why Monitor?. Personnel Safety inside Mechanical Rooms ASHRAE 15 Guideline Local Building Codes

annis
Download Presentation

Chillgard ® RT Refrigerant Monitors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chillgard® RT Refrigerant Monitors

  2. AGENDA • Why Monitor Refrigerants? • Photoacoustic Infrared Detection • Chillgard RT Features and Benefits • BACnet Capabilities • Summary

  3. Why Monitor? • Personnel Safety inside Mechanical Rooms • ASHRAE 15 Guideline • Local Building Codes • International Mechanical Code • Economics $$$$ • System Efficiency • Replacement Cost of Refrigerant • Potential Government (EPA) Fines

  4. Why Monitor? ASHRAE Guidelines ASHRAE 15

  5. Why Monitor? ASHRAE Guidelines ASHRAE 15 requires Entry-Way Signaling at each entrance of a Mechanical Room • MSA offers a variety of devices to meet this requirement • Strobes • Horns • Remote Display • Signs per specification

  6. Why Monitor? ASHRAE Guidelines ASHRAE 147: The Green Standard - Acknowledges Ozone Depletion and EPA Clean Air Act

  7. Where They Are Used • SCHOOLS • UNIVERSITIES • DATA CENTERS • COMMERCIAL BUILDINGS • HOTELS • CASINOS • HOSPITALS • CONVENTION CENTERS • INDUSTRIAL PLANTS

  8. Who are the Customers? • Chiller manufacturers • Building Control Companies • Contractors - HVAC & Mechanical • End Users -Direct sales • Hospitals, Universities, Government

  9. Infrared Detection Methodology • Both absorptive and photoacoustic techniques utilize infrared energy of a selective wavelength. • Majorityof gases absorb infrared energy of various wavelengths. • The wavelength selected for use in detection is determined by the gas in use and its specific characteristics.

  10. Photoacoustic InfraredGas Detection Technology How Does It Differ? To better understand the advantages of Photoacoustic Infrared Technology, we will briefly compare it to the older, more commonly used Absorptive InfraredTechnology. AbsorptiveInfraredTechnology PhotoacousticInfraredTechnology

  11. Infrared Technology Red is representative of a typical gas absorption characteristic. Yellow is an infrared wavelength used to detect this specific gas.

  12. Absorptive Technique All absorptive infrared detection methods differ from manufacturer-to-manufacturer. However, the basic principal remains the same. • Sample and reference measurements must be taken. • The sample cell is exposed to the gas to be detected. • The reference cell is either isolated from the gas to be detected or infrared energy outside the absorptive wavelength characteristics of the gas to be detected is used. • The two measurements are compared. If they are equal, the instrument will indicate zero (0).

  13. Absorptive Technique In this example, infrared sources deliver infrared energy through separate sample and reference cells to separate sample and reference detectors.

  14. Absorptive Technique • When the gas to be detected is present, it absorbs some portion of the sample infrared energy • The reference infrared energy is unaffected by the gas to be detected • The change in ratio of the sample and reference detectors is the actual concentration of gas present

  15. Photoacoustic Infrared Technology • Has been in use since the 1960’S • MSA – 10 Years of experience in PIR gas monitors • Has replaced many traditional infrared analyzers as well as other sensing technologies

  16. Photoacoustic Infrared Gas Detection Photoacoustic Infrared sensing technology differs from all other available detection techniques on the market. It has 2 distinct advantages: The ability to sense a leak as low as in the PPB level for some applications. The ability to operate long periods of time without adjustment or zero drift, a common problem with all other technologies in use today.

  17. Basic PIR Cell Assembly

  18. Photoacoustic IR Optical Bench IR source - wire filament emitting multiple wavelengths of light Chopper (not shown) - used to setup modulation Optical filters – • provide sensitivity and selectivity for a given gas • selected for specific application Optical block - volume can be changed for specific ranges Detector- high sensitivity microphone Solenoid valves - sample inlet and outlet provide seal during photoacoustic gas detection Heater and thermostat (not shown) - temperature control critical for low PPM or PPB detection

  19. CHILLGARD RT REFRIGERANT MONITOR

  20. Chillgard RT Monitor All Refrigerants & Ammonia Multiple Refrigerants, up to 6 Standalone Sample Draw System 1, 4, or 8 Channel Configuration NEMA 4 Design Premier Monitor on the Market

  21. Refrigerants Detected • R11, 12, 22, 123, 134A • 400 Series Refrigerants including R410A and R407C • 500 Series Refrigerants • New Refrigerants such R1234YF • Ammonia There isn’t a commercially available refrigerant that we can’t detect!

  22. Sample Points • Up to 8 points • Samples each point for 30 seconds when no gas present • Samples an extra 60 seconds if gas level exceeds threshold value • 150 ft w/ 1/8 inch id tubing • 500 feet w/ 3/16 inch id tubing

  23. Chillgard RT Monitor Photoacoustic Infrared Sensor Direct Measurement Technique Meets ASHRAE 15 & 147 Requirements UL2075 Performance to 1ppm

  24. Chillgard® RT Monitor Text Message Display 4-20 mA or 0-10V Output 3 Levels of Alarm Relays plus Fault Data Logging via RS-232 Local Event and Diagnostics

  25. Accessories • Remote relay package • Provides individual banks of relays for each point • Remote Display • Provides refrigerant level info before entering room • Filters, Calibration kits, tubing etc.

  26. BACnet • BACnet is acronym for Building Automation Controls network. • ASHRAE was a huge proponent in development of the protocol. Published as Standard ASHRAE/ANSI Std 135. • The key benefit to BACnet is that it allows communication across multiple product lines. • Major Building Controls Companies have migrated to BACnet as their choice of communication Protocol.

  27. BACnet capabilities • Millenium gateway from Industrial Control Communications provides BACnet MS/TP output • Can be connected to a Chillgard L series as well as an RT • Gateways will be loaded with a driver to convert from the MSA protocol to BACnet • PN 10117875 for the Chillgard L Series • PN 10117876 for the Chillgard RT

  28. BACnet Gateway • No configuration is necessary • Data is automatically mapped into database upon protocol selection • Fixed network characteristics • 19200 baud rate • 8 data bits • 1 start bit • 1 stop bit • No parity

  29. Wiring Instructions • Connect MSA monitors to the Gateway selected RS-485 port using a twisted-pair cable, connected as shown in the next slides • The gateway can be powered from the 12V supply on the Chillgard RT Monitor by connecting J14 terminals 1 (+12V) and 3 (GND) to POWER and GND Gateway terminals, respectively.

  30. Wiring to a Chilgard L series • Connect “+” (RS-485 to optional relay module terminal block for Chillgard LC and LE Monitors) to terminal “A” of the gateway, “-” (RS-485 to optional relay module terminal block for L series Monitors) connects to terminal “B” of the gateway, the ground terminal “G” (RS-485 to optional relay module terminal block for LC and LE) terminal to terminal GND of the gateway • Install jumper wires connecting terminal “A” to terminal “Y, and terminal “B” to • terminal “Z” on the gateway

  31. Wiring to a Chilgard RT • Connect “+ / A” (J15 terminal 2 or 4 for terminal of Chilgard RT to Gateway terminal “A”, “- / B” (J15 terminal 1 or 3 for Chillgard RT Monitor) terminal “B” and ground terminal GND (J14 terminal 3 for Chillgard RT Monitor) terminal to terminal GND. • Also install jumper wires connecting terminal A to terminal Y, and terminal B to • terminal Z on Gateway.

  32. How to order and notes • Contact MSA’s Custom Products group to purchase a Chillgard system with BACnet output • MSA will pre-load the configuration file to convert to BACnet based on either an L series or an RT • Gateway will provide BACnet objects that will need to be mapped to your network • Review the default configurations from the gateway with regards to the Chillgard mapping

  33. CHILLGARD RT Summary • PREMIER MONITOR ON THE MARKET • PROVEN, RELIABLE PHOTOACOUSTIC INFRARED TECHNOLOGY • CAN DETECT ANY REFRIGERANT DESIRED • UL 2075 APPROVAL – DETECTION TO 1 PPM

  34. Questions? THANK YOU !