30 likes | 144 Views
Conditioning StSt in the lab : energy dependence. e-gun energy. All done in a baked system No detectable energy dependence in this range. M.T., LIU-SPS 10/10/2012. Playing with venting of the system: results not reproducible, but……. sometimes very low SEY . unbaked vac. system
E N D
Conditioning StSt in the lab : energy dependence e-gun energy All done in a baked system No detectable energy dependence in this range M.T., LIU-SPS 10/10/2012
Playing with venting of the system: results not reproducible, but……. sometimes very low SEY unbaked vac. system (no C increase) unbaked vac. system, (C increase) unbaked vac. system, e-gun taken apart and cleaned (C increase) M.T., LIU-SPS 10/10/2012
Amount of carbon on the surface after e-beam irradiation and resulting SEY 1) In all cases when the SEY decreases to 1.1 there is an increase of C on the surface 2) No obvious differences in the residual gas (for carbon bearing species) M.T., LIU-SPS 10/10/2012