1 / 10

James N. Bellinger University of Wisconsin-Madison 13-October-2009

DCOPS Update. James N. Bellinger University of Wisconsin-Madison 13-October-2009. James N. Bellinger 13-October-2009. External Validation. PG exists for pre-field endcap disks PG exists for 8 transfer plates after CRAFT

apollo
Download Presentation

James N. Bellinger University of Wisconsin-Madison 13-October-2009

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DCOPS Update James N. Bellinger University of Wisconsin-Madison 13-October-2009 James N. Bellinger 13-October-2009

  2. James N. Bellinger 13-October-2009 External Validation PG exists for pre-field endcap disks PG exists for 8 transfer plates after CRAFT As of Monday night, no other relevant PG is available. The 8 transfer plates are supposed to be ready in CMS space later this week Recalculating the transfer plate positions gives tighter fit vs PG spreads

  3. James N. Bellinger 13-October-2009 Internal Validation of Z Z studies based on drawings and MAB fits strongly suggest that something is amiss in the Plus Endcap at transfer line 5. Omit this and estimate the endcap rotations using only un-PG-corrected transfer plate Z estimates (comparison shown later)

  4. Internal Validation of X/Y Consider the slice through the detector along the SLM2/Z plane Motion of the disks along the SLM line will appear in the L/R DCOPS measurements, in opposite directions on each side Lasers from each side should give the same pattern of center deviations from a line drawn from ME+4 center to ME-4 center PG measurements of TP positions should do the same, but with opposite sign James N. Bellinger 13-October-2009

  5. Example TP 1 and 4 Animated GIF Will not display in PDF Laser diffs (black) agree well with each other within a single line Cocoa fit includes other constraints No PG for MAB Large excursions in central region James N. Bellinger 13-October-2009

  6. James N. Bellinger 13-October-2009 Internal vs External Combining before and after PG (unwarranted and inaccurate) gives me deviations from the internal estimates of 4 transfer plates: 11.5, 3.4, 13.3 and 4.8mm Rotation estimates from Z are not fully consistent with (inappropriate) PG

  7. James N. Bellinger 13-October-2009 Pre-CRAFT Hack I used the CMS-SG-UR-0140 pre-CRAFT survey numbers in a Plus Endcap model together with my Transfer Plate PG numbers I don’t have Link data for this period I did not attempt to predict what the positions would be after the disks pulled together

  8. Example results: ME+1/3 Dubious about slopes here: need better Link coordination!

  9. Conclusions? Correcting Dave’s PG numbers for the relative positions of the transfer plates helps noticeably. I still have nothing to compare Z estimates from the Z-sensors to, or PG useful for aligning the SLMs. All we have is pre field-on. It could use some tweaking. Numbers for ME4 are supposed to be ready this week James N. Bellinger 13-October-2009

  10. James N. Bellinger 13-October-2009 BACKUP “I've been working for five days without any sleep to finish this report. At first I had a mental block. But on the fourth day I was visited by an Incan monkey god who told me what to write. Now I just have to find somebody who can translate his simple but beautiful language.” Scott Adams

More Related