210 likes | 323 Views
Design of a facility to host experiment mice in space. MDS. Mice Drawer System. Gabriele Baronio, Giancarlo Falcetti, Stefano Uberti, Valerio Villa. Device to host a colony of 6 mice in space (on board of ISS). Available commercial space (“ rack ”) with given interfaces.
E N D
Design of a facilityto host experiment micein space MDS Mice Drawer System Gabriele Baronio, Giancarlo Falcetti, Stefano Uberti, Valerio Villa
Device to host a colony of 6 mice in space (on board of ISS). • Available commercial space (“rack”)with given interfaces. • Functions: to feed, to water, administer controlled dosages of drugs, remove excrements, environmental conditioning. • 6 separate cages without contacts between mice. • Needs: guarantee mice’s physic and psychic well-being to have realistic results in experiments. MDS
Design targets Box: 440.1x253.2x516.1 [mm] 12mm insulation, only on lateral walls. Max dimensions Animals contained 6 Mice 30-40 days/mouse 90 day between launch and landing Permanence in space Switch on/off, Led, Data connector, Power connector, Air in filter, Air out filter, Water refilling connector, Food refilling opening Rack Panel connection
Needs Dimensions 6 cages + den max available surface Vmin=650 cm^3/mouse Air Filters in/out + Pump + Manifold + Vent-hole Reservoir (2-3l) + Pump + pipes Consumption: 20-30% mouse’s weight/day Water Food Food tablet Dry food x 100 days 3 Kg LHU (Liquid Handling Unit) Drug reservoir + Electrovalves + Metering pump
Bacteriological in & out Biological/microbiological Environment control Food reminder and excrements removing Cleaning Filters Decease management ? Temperature Heat exchanger Climatic control Humidity Desiccator Insulation Filters Management and Control Electronic unit Mobile camera camera + guide + motor
Electronic unit Biological/micro-biological Insulation Heat exchanger Water and food Available space Up/Down Lateral walls with insulation Materials Containers Rack panel
MDS Cages details
Final cage + Food handling
LHU can be distributed as we need, because it is pipe-connected and not rigid
Comparison between hypothesis Building elements