1 / 20

D. A. Orlov 1 , A.S. Terekhov 2 , C. Krantz 1 , S.N. Kosolobov 2 , A.S. Jaroshevich 2 , A. Wolf 1

Long term operation of high quantum yield GaAs-photocathodes at the electron target of the Heidelberg TSR using multiple recleaning by atomic hydrogen. D. A. Orlov 1 , A.S. Terekhov 2 , C. Krantz 1 , S.N. Kosolobov 2 , A.S. Jaroshevich 2 , A. Wolf 1.

Download Presentation

D. A. Orlov 1 , A.S. Terekhov 2 , C. Krantz 1 , S.N. Kosolobov 2 , A.S. Jaroshevich 2 , A. Wolf 1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Long term operation of high quantum yield GaAs-photocathodes at the electron target of the Heidelberg TSR using multiple recleaning by atomic hydrogen D. A. Orlov1, A.S. Terekhov2, C. Krantz1, S.N. Kosolobov2, A.S. Jaroshevich2, A. Wolf1 1 Max-Planck-Institut für Kernphysik, 69117, Heidelberg, Germany2 Institute of semiconductor Physics, 630090, Novosibirsk, Russia ~0.2 ... 8 MeV/u • Motivation: Photocathode multiple recleaning technique. Reliable, closed cycle, QY recovering. • TSR target. Photocathode performance. • Atomic hydrogen cleaning. • Capillary AH source at TSR target. • Results: UV-spectroscopy (H-treatment optimization). • Results: Multiple recleaning. • Outlook TSR Detectors (ions and neutrals) Photoelectron e-target Collector e- e-source Electron gun with magnetic expansion ≈10...90 Interaction section 1.5m Ion beam

  2. Photocathode performance at the electron target (A) Superconducting solenoid Gun chamber E-gun Preparation chamber Manipulator Loading chamber Hydrogen chamber collector Photoelectron target Merging region • Currents up to 1 mA (2 mA) • Lifetime - 24 h at 1 mA (2mA) • kT = 0.5-1.0 meV kT|| = 0.02 meV E-gun

  3. GaAs GaAs Photocathode performance (B): Lifetime H2O O2 CO2 1. Dark lifetime (RT) > weeks (UHV) CO CH4 H2O O2 CO2 2. Dark lifetime (LT): hour-weeks(temperature) Cryosorption! T > 130 K Cold CO+, CH4+… 3. Operating high-current lifetime: Ion deflection, barrier! e Ion back stream! GaAs E (e-current, energy, pressure, geometry) B Beam profiles (D=12 mm) Start Degraded

  4. GaAs oven Atomic hydrogen cleaning RF coil 1. RF plasma discharge source. H2 H Energetic particles from the source!Risk of photocathode damage! GaAs oven 2. Hot filament source. H2 oven Low efficiency!Cathode heating! High partial pressure of W! 3. Hot capillary source W-capillary H2 GaAs Just good ;-). oven

  5. W-capillary 1900 K H2 GaAs oven oven AH treatment at the TSR target. Hot capillary source. Efficient Narrow angular distribution of H-atoms Low capillary temperature (no W-contamination) Leak valve Leak valve palladium tube palladium tube P=1.0E-08 mbar H2 manipulator W-capillary H manipulator filament sample oven H2

  6. oven AH treatment at the TSR target. Hot capillary source. W-capillary 1900 K H2 GaAs oven T=450o C t=5-10 min Based on the data: K.G. Tschersich, JAP 87, 2565 (2000) Leak valve palladium tube P=1.0E-08 mbar When heat-cleaning does not help (after 3-5 times) H2 W-capillary H-treatment (typical): Tcathode=4500 CH-flux: 5E14 atoms/cm2/sExposure time: 5-10 minExposure: 50-200 L manipulator filament sample oven In 5 min transfer the sample to Prep. ChamberHeat-cleaning at 400-4500 C for 30 min.

  7. AH cleaning: UV spectroscopy Cs/O layer removing by H0: Clean -> CsO -> H Cs/O layer removing by H0: H-dose optimization different H0-exposures 10 L 200 L 1. After 4 CsO activations + heat-cleaning QY (electron/photon), % QY (electron/photon), % 4. H-cleaning 3. Cs + heat-cleaning 2. Clean (HCL + ISO) 6.0 5.0 4.0 3.0 6.0 5.0 4.0 3.0 Photon energy, eV Photon energy, eV - Accumulation of Ga/As oxides after multiple reactivations. - AH efficiently removes oxides. - The small presence of Cs. To remove Ga and As oxides the AH exposure of about 100 L is enough.

  8. Atomic hydrogen: multiple recleaning 25 40 1.5 year of operation! (21 AH treatment, > 80 activation, 120 heat cleaning) 35 20 30 25 15 20 QY (electron/photon), % QY (electron/photon), % 10 15 LPE grown transmission mode photcathode MOCVD grown transmission mode photcathode 10 5 5 0 0 0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 H0 dose, L H0 dose, L AH multiple cleaning works almost perfectly with only slow QY decrease for MOCVD grown photocathodes.

  9. QY degradation: heat-induced? 1. Accumulation of oxygen? NO! 2. Arsenic vacancies defects? NO! 3. Heat-cleaning induced degradation of transmission mode cathodes (mechanical strain)? YES!

  10. QY degradation: heat-induced dislocations? 1. Accumulation of oxygen? NO! 2. Arsenic defects (vacancies)? NO! 3. Heat-cleaning induced dislocations at the substrate (sapphire)-heterostructure interface? AFM-image of photocathode with “smooth” surface AFM-image of photocathode after multiple recleaning Peaks height 30-50 nm RMS = 0.2 nm Dislocation net Outside of peaks RMS = 0.5 nm

  11. Conclusions & Outlook Multiple recleaning of high QY photocathodes – it works! Slow QY degradation is probably due to heat-induced defects (dislocations at the sapphire-heterostrucrure interface). Still can be improved.

  12. Detectors Photocathode setup Collectorsection Acceleration section TSR dipole Interaction section vertical correction dipoles Toroid section TSR quadrupole 1.5 m Ion beam TSR electron target section - overview

  13. Superconducting solenoid Gun chamber Preparation chamber Manipulator Loading chamber Hydrogen chamber Photocathode section - overview

  14. 1 mbar x 10 min, 1520 ML 1 mbar x 10 min, 1520 ML HCL HCL 5 AH 2 AH 3 AH 3 AH 3 AH 1.5 mbar x 10 min (1st AH), 2280 ML 0.1 mbar x 10 min, 152 ML 0.3 mbar x 5 min 228 ML 0.3 mbar x 10 min, 456 ML palladium tube H2 W-capillary filament sample oven Closed cycle of operation with atomic hydrogen treatment QY (electron/photon), % QY (electron/photon), % The evolution of QY UV spectra for different AH-exposures

  15. TSR photoelectron target Detectors (ions and neutrals) ~0.2 ... 8 MeV/u Neutrals detector Movable ion detector e-target Collector Electron gun with magnetic expansion ≈10...90 TSR dipole e-source Adiabatic acceleration e- Interaction section 1.5m Ion beam

  16. 1 mbar x 10 min, 1520 ML 1 mbar x 10 min, 1520 ML HCL HCL 5 AH 2 AH 3 AH 3 AH 3 AH 1.5 mbar x 10 min (1st AH), 2280 ML 0.1 mbar x 10 min, 152 ML 0.3 mbar x 5 min 228 ML 0.3 mbar x 10 min, 456 ML Fig.3 The figure shows the “history” of the N5-photocathode in the Heidelberg target (>1 year). In total the sample experienced more than 100 heat-treatment. Each minimum correspond “Cs-activation” which typically goes after H-treatment, except of N=85, where no Cs-cleaning was used. Others intermediate points correspond to 1, 2, 3 or 4-th activation. The values of AH-exposure are also indicated on the figure.

  17. Atomic hydrogen cleaning: UV spectroscopy Fig.1 The spectra was measured after HCL or H-treatment or after activation by Cs or Cs/O with subsequent heating. The steps are described in the picture and ordering goes from up to down (the first step “before HCL”, the last on – “Cs/O2 +6.5 A” for N5 and “7.0 A + Cs +6.5 A” for N6). Find on the next page detailed description of the steps.

  18. 1 year of operation! 120 cycles (23 AH treatment) QY (electron/photon), % Cryogenic photocathode source Cs/O layer removing by H0 Photocathode setup different H0-exposures low high QY (electron/photon), % Quantum Yield vs UV photon energy Photocathode at 100 K 6.0 5.0 4.0 3.0 Photon energy, eV Atomic hydrogen cleaning: Vacuum conditions: UHV (5∙10-12 mbar) H2O, O2, CO2 <10-14 mbar High requirements for surface preparation Number of steps (H0 or heat-cleaning)

  19. Photocathode performance at the electron target (A) Photoelectron target T-control (heat cleaning, operation): Photoluminescence & IR transmission spectroscopes, photoelectron spectra Surface cleaning quality: UV QY spectroscopy Emission properties: 2D energy distribution • Currents up to 1 mA (2 mA) • Lifetime - 24 h at 1 mA (2mA) • kT = 0.5-1.0 meV kT|| = 0.02 meV