1 / 3

Reconsidered EPA Boiler MACT / GACT Rules

Reconsidered EPA Boiler MACT / GACT Rules. Steve Schliesser Engineer, Planning Section Division of Air Quality Feb 19, 2013 - Outside Involvement Committee Meeting. Reconsidered Boiler MACT for Major Sources –Key Changes and Highlights.

aspen
Download Presentation

Reconsidered EPA Boiler MACT / GACT Rules

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Reconsidered EPA Boiler MACT / GACT Rules Steve Schliesser Engineer, Planning Section Division of Air Quality Feb 19, 2013 - Outside Involvement Committee Meeting

  2. Reconsidered Boiler MACT for Major Sources –Key Changes and Highlights • 21 Boiler / Fuel subcategories for units > 10 million Btu/hr heat input - New subcategories for light (#1, 2) and heavy (#4 - 6) oils along with wet and dry biomass fuels • Higher PM emission limits for each fuel oil / biomass subcategory • Higher CO emission limits based on new data showing variability. • Lower emission limits for other pollutants / subcategories • Gas fired units subject to annual tune-ups but no emission limits • All affected units subject to one-time energy assessment • Nearly all NC affected facilities covering ~1,000 boilers have 112(j) permits shielding Boiler MACT compliance up to May 20, 2019 • Existing units Boiler MACT compliance date: - with 112(j) permit = May 2019; without it = January 2016

  3. Reconsidered Boiler GACT for Area Sources – Key Changes and Highlights • Initial notification due January 20, 2014 • Initial tune-up and energy assessment compliance date extended 2 years to March 21, 2014 - ISO 50001 energy assessment considered equivalent • Existing dual-fuel units switching from gas to coal, biomass or oil now considered ‘existing’ units  • Tune-ups every 5 years, instead of every 2, for seasonal, limited use, small oil-fired, and boilers with oxygen trim • No PM limits for new boilers with < 0.5% sulfur oil • Higher mercury and CO emission limits for coal boilers • Clearer, broader definition of biomass fuels and energy assessment requirements • Gas fired units not subject to tune-ups or emission limits

More Related