710 likes | 1.47k Views
Geothermal Energy Power Generation. San Jose State University FX Rongère March 2009. Geothermal Power Generation in the World. Located along the main plate boundaries. Hydrothermal Sites. Source: Boyle, Renewable Energy, 2 nd edition, 2004. The Geysers (CA). Power generation: 1,400 MWe.
E N D
Geothermal EnergyPower Generation San Jose State University FX Rongère March 2009
Geothermal Power Generation in the World • Located along the main plate boundaries
Hydrothermal Sites Source: Boyle, Renewable Energy, 2nd edition, 2004
The Geysers (CA) Power generation: 1,400 MWe
Caenozoic: Sedimentary non marine Sedimentary marine Volcanic Mezozoic Paleozoic Intrusive Igneous Rocks Granite Ultramafic The Geysers Geology The Geysers
Geologic Time C B A
The Geysers Geology • Typical Porosities of ground material
Geysers Geothermal resource A steam reservoir is located about 2,000 meters under the surface
Geothermal resource at the Geysers The Geysers
Dry Steam Cycle • At Geysers, the steam is dry (250oC – 30 bars). It is directly used to drive steam turbines
Steam Cycle • It is an open Rankine Cycle (the ground is the Steam Generator)
h-s Diagram • Enthalpy variation may directly be read on the diagram
Steam turbines cannot resist to more than 12% of water drops in low pressure steam Multi-stage steam turbine are used Generated Power • Computations of the power by the turbine • Isentropic (Perfect) Turbine • Actual Turbine Intersection of vertical from and P=0.056 bars
Heat rejected at the Condenser • Energy balance on the condenser
Rejected Heat • Computation of the heat rejected at the condenser
Water Re-injection • In 1997 and 2003 a re-injection system was built to offset the depletion of the Geysers steam reservoir. It provides 19 M Gallons per day (=832 kg.s-1). This re-injection should covered a power generation of 830 MW
Casa Diablo • Located by the Mammoth Mountain on the East side of the Sierra Nevada About 40MW by three power plants
Bishop Tuff Porosity: 48% to 65% Source: J. Roberge Permeability study of pumice samples from the Bishop Tuff, Long Valley Caldera, CA American Geophysical Union, Spring Meeting 2004, abstract #V21A-07
Caldera Formation • The caldera was formed 760,000 years ago by the explosion of a volcano
Hydrology • Water flow starts in the west by the Mammoth Mountain and continues to the southeast toward Crowley Lake. • Reservoir temperatures decline from 230°C near the Inyo Craters to 50°C near Crowley Lake
Geothermal resource at Casa Diablo Casa Diablo The Geysers
Water Extraction • Because of the low temperature and no impermeable cap, there is no steam and the system is not pressurized • Hot water is pumped from the reservoir to run the Power Plant
Binary Cycle Power Plant • At Casa Diablo, the thermal water temperature is only 170oC. The Power Plant uses a Binary Cycle with Isobutane as the working fluid
Why the iso-butane? • Evaporation temperature is lower than for steam • Higher pressure at the turbine -> Cheaper turbine
Enthalpy-Entropy Diagram
Summary • Fluid state at each connection point:
Power delivered by the turbine
Heat transferred at the Condenser • Energy balance on the condenser
Water Branch of the Condenser • We can assess the flow of water required to cool the condenser Tw-inis imposed by the weather conditions, sizing for the hottest day: 30oC (dry Aero-Condenser) Tw-outis limited by the temperature in the condenser
Graph Enthalpy-Temperature • The two lines cannot intersect because heat goes naturally from the hotter to the colder fluid (Second law of Thermodynamics) n-butane out water in
Effect of dry Aero-Condensor • Air dew point defines the evaporation • Wet-bulb temperature defines the lowest temperature for water evaporating in an air stream Wet-bulb Temperature Dew Point
Effect of dry Aero-Condensor • With evaporative cooling towers the temperature of water entering the condenser would have been 15oC • This would allow a condenser temperature of 20oC rather than 35oC leading to a gain of 2 points in conversion rate
Pump • The pump brings the n-butane back to high pressure • Its power is much lower than the Turbine power because the fluid is liquid
Evaporator • Energy balance on the evaporator
Water Branch of the Evaporator • We can assess the flow of water required to cool the evaporator Ta-inis imposed by the water temperature of the Geothermal resource Ta-outis limited by the temperature in the evaporator
Graph Enthalpy-Temperature • The two lines cannot intersect because heat goes naturally from the hotter to the colder fluid (Second law of Thermodynamics) in water out n-butane
Summary • Balance of Energy and Entropy on each component • Conversion rate:
Imperial Valley • Located between Salten Sea and the Gulf of California Salten Sea units 3 and 4 570 MW by 15 power plants
Imperial Valley Geology About 300oC at -1,000 m
Cenozoic: Sedimentary non marine Sedimentary marine Volcanic Mezozoic Paleozoic Intrusive Igneous Rocks Granite Ultramafic Geology
Geothermal resource at Casa Diablo Casa Diablo Salten Sea The Geysers
Steam Flash Cycle • Simple flash cycle: 30bars – 230oC
Simple Steam Flash Vap 230oC 50 bars, 300oC Liq
Steam Flash Cycle • Double flash cycle
Double Steam Flash Vap 10 bar Liq
Geothermal Power in California In Operation: 2,400 MWe Total Potential: 4,900 MWe Source: California Geothermal Energy Collaborative/GeothermEx, 2006
Hot Dry Rock (HDR) • Injection of water in a dry hot rock • A Hot Rock Source: Granite that is generating abnormally high internal heat from the natural radioactive decay of minerals • An insulating blanket of sediments, that effectively entraps the heat generated from the buried granite. • Adequate fracturing of the hot dry rock source that allows circulation of a horizontal fluid flow regime Source: http://www.geothermal-resources.com.au/exploration.html