570 likes | 595 Views
Axiva Sichem Pvt.Ltd appreciated for manufacturer, supplier and exporter a premium quality of laboratory filtration products. Our offered product ranges are made by the well capable professionals by utilizing optimum quality basic inputs and as per international standard, that’s why our company provides the technical specification of products to our clients. http://www.axivafilters.com/products/lab-filtration/filtration/qualitative-filter-paper/
E N D
Innovative Filtration Solution Laboratory Filtration Product Technical Details
Axiva Strength • An Eight years old company. • A dedicated team of 70 professionals. • In-house Analytical Labs for Quality consistency and R & D. • “AXIVA ” brand Available in more than 45 countries across the • globe. • Every filter box is supplied with ‘COA’ inside. • Sterilization certificate available for every batch with protocol
Quality Assurance Quality Assurance Lab is studded with all modern instruments including “HPLC” Trained & experienced Scientists are working to ensure quality in each & every filter.
Product Technical Details
Syringe Filters – Non Sterile • Nylon • PTFE • PVDF • CA • PES • MCE • Glass fibre • Double Layered • Triple Layered
Nylon Syringe Filters - Non Sterile Target Market : Pharma – QC & R&D Applications : • HPLC Solvents Sample Filtration • Mobile phase separation • For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Available Porosity : 0.22 & 0.45 microns • Technical Specification : • Wetability : Hydrophilic • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 35.4 ml/min for 0.2 μm & 67.2 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
PTFE Syringe Filters - Non Sterile Applications : • For Analytical and Research applications & for Air sampling. • Used under extreme chemical or temp. Conditions. • For non- aqueous base organic solvent filtration • Ideal for filtration of highly aggressive colloidal solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophobic • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 21 ml/min for 0.2 μm & 29.3 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
PVDF Syringe Filters - Non Sterile • Applications : • For Analytical and Research applications. • • For aqueous as well as organic solvent filtration • • Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 41.3 ml/min for 0.2 μm & 94.3 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
CA Syringe Filters - Non Sterile • Applications : • Suitable for filtration of Protein solutions. • • For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 38.4 ml/min for 0.2 μm & 72.3 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
PES Syringe Filters - Non Sterile • Applications : • For Analytical and Research applications. • • Recommended for aqueous as well as organic solvent filtration • • Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
MCE Syringe Filters - Non Sterile • Applications : • For Analytical and Research applications. • • Recommended for aqueous as well as organic solvent filtration • • Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
Glass Fiber Syringe Filters - Non Sterile Applications : • Sample cleaning • Particle removal • For High throughput • Removes particulate that interferes with UV/VIS spectrophotometric analysis • Can be used alone or in series with another Axiva syringe filter Available sizes : 13 mm, 25 mm, 33 mm Technical Specification : Effective Filtration Area : 0.8 cm for 13mm & 3.9 for 25mm Sample Volume : <20ml for 13mm & <150 ml for 25mm Typical Hold-Up Volume (with air purge) : <20μl for 13mm and <100μl for 25mm Maximum Operating Temperature : 82°C (180°F) at 2.1 bar (210 kPa, 30 psi) Typical Water Flow Rate : 795 ml/min at 1.0 bar
Double Layered Syringe Filters -Non Sterile Applications : • Sample cleaning • Particle removal • For High throughput • Removes particulate that interferes with UV/VIS spectrophotometric analysis • Can be used alone or in series with another Axiva syringe filter Available sizes : 13 mm, 25 mm • Technical Specification : • They are widely applicable for filtration of colloidal solutions. • • Also used in the filtration of typical filter solution (viscous solutions)
Triple Layered Syringe Filters -Non Sterile • Applications : • Eliminates sample contamination • • Requires less hand pressure, even with the most difficult samples • • Processes three to seven times more sample volume Available sizes : 25 mm • Technical Specification : • They are widely applicable for filtration of colloidal solutions. • • Also used in the filtration of typical filter solution (viscous solutions)
Sterilized Syringe Filters • Nylon • PTFE • PVDF • CA • PES • MCE • Double Layered • Triple Layered
Nylon Syringe Filters - Sterile Applications : • HPLC Solvents Sample Filtration • Mobile phase separation • For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Sterilization : ETO • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 35.4 ml/min for 0.2 μm & 67.2 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
PTFE Syringe Filters - Sterile Applications : • For Analytical and Research applications & for Air sampling. • Used under extreme chemical or temp. Conditions. • For non- aqueous base organic solvent filtration • Ideal for filtration of highly aggressive colloidal solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophobic • Sterilization : ETO • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 21 ml/min for 0.2 μm & 29.3 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
PVDF Syringe Filters - Sterile Applications : For Analytical and Research applications. • For aqueous as well as organic solvent filtration • Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Sterilization : ETO • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 41.3 ml/min for 0.2 μm & 94.3 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
CA Syringe Filters - Sterile • Applications : • Suitable for filtration of Protein solutions. • • For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Sterilization : ETO • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 38.4 ml/min for 0.2 μm & 72.3 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
PES Syringe Filters - Sterile • Applications : • For Analytical and Research applications. • • Recommended for aqueous as well as organic solvent filtration • • Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Sterilization : ETO • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
MCE Syringe Filters - Sterile • Applications : • For Analytical and Research applications. • • Recommended for aqueous as well as organic solvent filtration • • Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm • Technical Specification : • Wettability : Hydrophilic • Sterilization : ETO • Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm • Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) • Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm • Extractable (NVR) : Very low (within limit as specified in USP XXIV) • Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) • Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
Double Layered Syringe Filters -Sterile Applications : • Sample cleaning • Particle removal • For High throughput • Removes particulate that interferes with UV/VIS spectrophotometric analysis • Can be used alone or in series with another Axiva syringe filter Available sizes : 13 mm, 25 mm • Technical Specification : • They are widely applicable for filtration of colloidal solutions. • • Also used in the filtration of typical filter solution (viscous solutions)
Triple Layered Syringe Filters - Sterile • Applications : • Eliminates sample contamination • • Requires less hand pressure, even with the most difficult samples • • Processes three to seven times more sample volume Available sizes : 25 mm • Technical Specification : • They are widely applicable for filtration of colloidal solutions. • • Also used in the filtration of typical filter solution (viscous solutions)
Air Vent Filters PTFE
Air Vent Filters • Applications : • • Applicable for small volume venting & degassing Venting bioreactors • • Fermentation tanks & carboys Sterile gas purging of culture vessel • Pharmaceutical vents • Laboratory : clean or sterile: gases, solvents, reagents, drying gases • • Electronics : photo resists, solvents, gases for research Available sizes : 50 mm Technical Specification : Wettability : Hydrophobic Sterilization : ETO Max. Operating Pressure : 60 psi Bubble Point : > 24 psi in 70% IPA Air Flow Rate : 10 NLPM at 50 psi Housing Burst at 25°C : 75 psi (5.17 bar)
Membrane Disc Filters • Nylon • C.N. • P.T.F.E. • P.E.S
Nylon Membrane Filter Applications : • Sterilizing filtration of aq. solution & Bioassay • Ideal for HPLC solvents • Mobile phase separation & Solvent filtration Available sizes : 13 mm, 25 mm, 47 mm Technical Specification : Color : White Wettability : Hydrophilic Extractable (NVR) : Very low (within limit as specified in USP XXIV) Surface : Plain Operating Temp. : 0 75 C (max) Heat Stability : Maintain integrity for 5 cycles of autoclave at 1210C for 30 minutes
C.N. Membrane Filter – Non Sterile • Applications : • Ideal for microbial analysis. • • Suitable for aqueous and protein filtration. Available sizes : 13 mm, 25 mm, 47 mm, 90 mm Technical Specification : Color : White Wettability : Hydrophilic Surface : Plain
C.N. Membrane Filter - Sterile • Applications : • Ideal for microbial analysis. • • Suitable for aqueous and protein filtration. Available sizes : 47 mm Technical Specification : Color : White Wettability : Hydrophilic Surface : Plain Sterilization : ETO
Gridded Membrane Filters Cellulose Nitrate Sterile (Individually packed)
Gridded Membrane Filters - Sterile • Applications : • Ideal for microbial analysis. • • Suitable for aqueous & protein filtration and protein analysis Available sizes : 47 mm Technical Specification : Color : White Wettability : Hydrophilic Surface : Gridded, Black Sterilization : ETO
PTFE Membrane Filter Applications : • For Analytical and Research applications & for Air sampling • Used under extreme chemical or temp. Conditions • For non- aqueous base organic solvent filtration • Ideal for filtration of highly aggressive colloidal solutions Available sizes : 13 mm, 25 mm, 47 mm, 142 mm Technical Specification : Color : White Wettability : Hydrophobic Extractable (NVR) : Very low (within limit as specified in USP XXIV) Surface : Plain
PES Membrane Filter Applications : • For Protein sampling • For aqueous as well as organic solvent filtration • Prevent blow through low molecular weight protein • Filtration of difficult filter solutions Available sizes : 13 mm, 25 mm, 47 mm, 142 mm Technical Specification : Color : White Wettability : Hydrophilic Extractable (NVR) : Very low (within limit as specified in USP XXIV) Surface : Plain Heat Stability : Maintain integrity for 5 cycles of autoclave at 121 Degree Celsius for 30 minutes
Blotting Membranes • Nylon • C.N • In rolls & sheets.
C.N. Blotting Membrane Applications : • Ideal for Microbiology Analysis • Suitable for aq. and protein filtration • Recommended for Western Blotting • Applicable for low molecular weight proteins. Available sizes : 100 X 100 mm, 200 X 200 mm, 300 X 300 mm, 300 mm X 3 meters Technical Specification : Wettability : Hydrophilic Maximal Protein/nucleic acid binding : upto 80 -100 μm/cm sq.
Nylon Blotting Membrane Applications : • Ideal for DNA & RNA transfers • Recommended for Southern Blotting. Available sizes : 100 X 100 mm, 200 X 200 mm, 300 X 300 mm, 300 mm X 3 meters Technical Specification : Wettability : Hydrophilic High binding capacity : 99.7%
Glass Fibre Filters • GF/1F • GF/3F • 2934 AX
Filter Funnel • Plastic Filter Funnel • Glass Filter Funnel • S.S. Filter Funnel
Plastic Filter Funnel Applications : Have three vent on top for dosing. Silicon Cover Provided Available sizes : 47 mm Technical Specification : Polycarbonate P. P. with silicon ‘O’ ring and cork. Recessed filter support and graduated funnel. Funnel cover can be vented asceptically using disposable PTFE filter.
Glass Filter Funnel Available sizes : 47 mm
S.S. Filter Funnel Applications : Provide large filtration area, Unique design for high flow rate. Available sizes : 47 mm Technical Specification : All Stainless Steel 316 with external S. S. clamp & Neoprene
Filter Holders • S.S. Filter Holders • Plastic Filter Holders
S.S. Filter holders Applications : Provide large filtration area, Unique design for high flow rate & Widely compatible. Available sizes : 13 mm, 25 mm Technical Specification : Body : S. S. 316 Mesh : S. S. 316 Gasket : PTFE
Plastic Filter holders Applications : Provide large filtration area, Unique design for high flow rate & Widely compatible. Available sizes : 13 mm, 25 mm Technical Specification : Body : Polycarbonate Transparent Mesh : Polycarbonate Transparent Gasket : Silicone
Filtration Assembly • Single place • Three Place • Six Place
Vacuum Pumps • For Single Place Assembly: • Maximum Flow : 15 LPM • FOR 3 & 6 PLACE ASSEMBLY • Maximum Flow : 45 LPM
Vacuum Pumps - single place Applications : High product recovery, suitable for Single place filtration assemblies Technical Specification : Maximum vacuum : 23 (in Hg) Maximum Flow : 15 LPM Motor : 1/8 HP Power : 220 - 230 V
Vacuum Pumps – 3 & 6 place Applications : High product recovery, For superfine filtration. suitable for high filtration assemblies Technical Specification : Maximum vacuum : 26 (in Hg) Maximum Flow : 45 LPM Motor : 1/4 HP Power : 220 - 230 V
Filter Papers • Qualitative Filter Papers