1 / 9

Heated plate curing

Heated plate curing. Gluing and Measuring (130nm hybrIds) Trying to adjust touchdown pins on ASIC placement jig for flatness. Check after gluing glass ASICS (room tempo cure). Shear testing Use Dage 4000 to shear-test the glass ASICs glued above (though the

axl
Download Presentation

Heated plate curing

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Heated plate curing • Gluing and Measuring (130nm hybrIds) • Trying to adjust touchdown pins on ASIC placement jig for flatness. • Check after gluing glass ASICS (room tempo cure). • Shear testing • Use Dage 4000 to shear-test the glass ASICs glued above (though the • glue thicknesses are awry) WP3; 20 Mar2014; John Wilson

  2. Adjustment of placement jig ASIC Placement Jig Touchdown pin Assembly Dowels Aluminium tooling plate Mini heating element Feeler gauges • Feeler gauges, placed between the jig and plate: • gauge thickness = glue thickness + ASIC thickness + height of hybrid from panel. • ( 80μm + 310μm + - 50μm ) = 340μm WP3; 20 Mar2014; John Wilson

  3. Measure the resistance of each touchdown pin, stopping when it becomes finite But find that pins are adjusted ~40µm too long. The metal plate had small dents in the surface under the touchdown pins. Placing shims (of the same thickness) under the vacuum pads and spacing shims, and under the touchdown pins, has removed these surface dents. Now we achieve the target height. WP3; 20 Mar2014; John Wilson

  4. After gluing and room temp curing, measure the heights of the ASICs above the touchdown pads. The ASIC height should be equal to the distance set when adjusting the jig (i.e. 340μm) . In fact, the ASIC height is ~ 50 µm lower → a reduced glue thickness.

  5. The Glue Thicknesses are ~50µm than expected. The shape stays consistent with what we expected but it looks as if the whole jig has somehow ‘sunk’ into the panel WP3; 20 Mar2014; John Wilson

  6. Adjustment of placement jig There is a small dent in the centre of each of the ‘touch down pads’ We estimate this dent, has lowered the whole jig by ~50µm. We think this has occurred because of the tight fit of the jig to the panel. Quite a force is required on to the jig to get it to sit correctly → dent on surface? We have reamed out the holes on the panel to make the jig fit better. Will glue another hybrid to see if the problem persists. WP3; 20 Mar2014; John Wilson

  7. Dage 4000 : shear tests • Need to support the hybrid firmly during the shear test: • Videos of shearing available! Shear tool Clamp Plate with lip to stop hybrid sliding WP3; 20 Mar2014; John Wilson

  8. Dage 4000 : shear tests (contd) During these two shear tests the jig holding the hybrid twisted which is why there is a lower value recorded. WP3; 20 Mar2014; John Wilson

  9. Dage 4000 : shear tests (contd) No conclusions since glue thickness is wrong but glue joints seem very strong! i.e. within spec (MIL-STD-883G): if die area exceeds 4.1 sq mm, shearing at ≤ 2.5kg ≡ FAILURE; shearing at ≥ 5.0kg and adhesion over > 75% of area ≡ SUCCESS. Aim for ≥ 5.0kg WP3; 20 Mar2014; John Wilson