An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Joint SA-SEAP Ozone Officers Network Meeting Pattaya, Thailand 15-18 October 2012 CHALLENGES FOR HCFC PHASE-OUT IN AIR CONDITIONING

  2. BACKGROUND • HCFC phase-out in developing countries has started. Short/medium term targets: Freeze in 2013, 10% reductions from 2015, 35% reductions from 2020. • HCFC-22 is the predominant refrigerant used in air- conditioners in developing countries • Consumption of HCFC-22 in manufacturing and servicing of air-conditioners in major developing countries is significant (typically >70% of total HCFC consumption) and growing rapidly

  3. MARKET FOR AIR-CONDITIONERS • Market for air-conditioners growing rapidly in developing countries – low baseline market penetration • Estimated HCFC-22 based room air-conditioner sales (2011) in key developing countries in Asia-Pacific:

  4. MARKET FOR AIR CONDITIONERS (CONT’D) • By 2020, market for air-conditioners in Asia-Pacific could reach >100 million units and sales >US$ 20 billion • By 2025, ~1 billion city dwellers will “enter the global consuming class”: an air-conditioner would be their first purchase* • Most booming cities are in tropical climates • Refrigerant charge volumes for new air-conditioners sold in Asia-Pacific (developing countries in 2011) estimated at ~50,000 metric tonnes annually(!) • ____________________________ • * McKinsey Global Initiative

  5. ENERGY USE • Electricity use for air conditioning in some cities with tropical weather: • Bangkok, Thailand – 60% • Delhi, India – 55% • Miami, USA – 40% • Mumbai, India – 50% • And the list goes on ……. • Electricity use for air conditioning at the national level can range from <5% (temperate zones) to over 80% (some tropical/equatorial island states)

  6. DIRECT AND INDIRECT EMISSIONS • Global air-conditioner population is estimated at about 500 million to 1 billion (and growing)!! • Use HCFCs or HFCs as refrigerants, both high GWP gases • Each air-conditioner contains average 1-1.5 kg of refrigerant and has 1.5 to 4 kw connected electrical load • Annual direct and indirect CO2 emissions from air conditioners globally, could be between 1 to 4 gt (1 to 4 billion CO2-eq tonnes)!!!

  7. BACKGROUND (CONT’D)

  8. BACKGROUND (CONT’D)

  9. BACKGROUND (CONT’D)

  10. BACKGROUND (CONT’D)

  11. TECHNOLOGY • Need for lifecycle management approach in technology selection • Manufacturing • Use • End of Life

  12. TECHNOLOGY • MOP Decision XIX/6 urges maximizing climate benefits when phasing out HCFCs • Lifecycle CO2 emissions from air-conditioners are 60-95% indirect and 5-40% direct. In developing countries direct emissions are higher due to local conditions • Both energy use and refrigerant GWP are critical considerations to maximize climate benefits • Currently there is no perfect alternative for HCFC-22. HFC and HC candidates involve compromises and trade-offs

  13. TECHNOLOGY (CONT’D) • R-410A (GWP = 2,088*) has been the preferred alternative in developed country markets since ~2000. • Population of air-conditioners with R-410A is already about 200 million (Dec 2010), mostly in developed countries: about 200,000 metric tonnes of R-410A in banks and increasing! • R-410A energy-efficiency performance in general and in high-ambient conditions in particular • Is R-410A a sustainable alternative for minimizing adverse climate impacts? • ____________________________ • * IPCC 4th Assessment Report

  14. KEY ISSUES AND CONCERNS • Reducing HCFC-22 consumption in developing countries without clear technology and policy signals, will result in unintended and adverse climate impacts • For example, if developing countries prohibit HCFC-22 based air-conditioners (manufacturing and imports), automatic technology choice is likely to be R-410A. • Major developed-country technology providers showing preference for R-410A (e.g. R&D focus on optimizing R-410 systems and components, new products based on R-410A etc.)

  15. KEY ISSUES AND CONCERNS • Significant expansion of HFC production facilities • Extensive introduction of high-GWP technologies will lead to rapid increase in population of air-conditioners in developing countries, based on these technologies • Considering prospective developing country markets by 2020, the net climate impact of HCFC phase-out with high-GWP technology, is most likely to be negative! • A better, more forward-looking and climate-conscious approach to alternatives is needed!

  16. WAY FORWARD • What can industry do? • Introduce and promote low-GWP, energy-efficient alternatives (R-32, R-290, others) on priority • Support sustained R&D for new, better and safer molecules for substituting HCFC-22, as well as optimized components (e.g. compressors). • Cooperate with MP panels and implementing agencies for sharing and disseminating latest technologies (e.g. demonstration projects, technology workshops)

  17. WAY FORWARD • What can developing country governments do? • Support incentives for better alternatives • Support policies that ensure level playing field for the industry players • ‘ • Involve industry in formulation of policies and regulations • Support targeted and clear regulations that take into account GWP and energy efficiency

  18. WHAT WE ARE DOING MLF FUNDING Maximum climate impact Direct Emission Reductions (low-GWP alternatives) Montreal Protocol Measures (HCFC Phase-out) GEF/ BILATERAL/ PRIVATE-SECTOR FUNDING Indirect Emission Reductions (EE improvements) Design interventions with dual objectives of ozone and climate protection

  19. THANK YOU! Comments, suggestions and questions welcome http://www.undp.org/chemicals/montrealprotocol.htm nandan.chirmulay@undp.org