1 / 17

STATUS OF DAQ PROJECT

STATUS OF DAQ PROJECT. T.T. LOW VOLTAGE POWER SUPPLIES NETWORK, RACKS & CABLING PT DAQ DEVELOPMENTS CONCLUSIONS. OPERA collaboration meeting, Hamburg, 3-5 June, ’04. J.Marteau. TT LOW VOLTAGE POWER SUPPLIES. POWER SUPPLIES COST : 2 options can be considered

Download Presentation

STATUS OF DAQ PROJECT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STATUS OF DAQ PROJECT • T.T. LOW VOLTAGE POWER SUPPLIES • NETWORK, RACKS & CABLING • PT DAQ DEVELOPMENTSCONCLUSIONS OPERA collaboration meeting, Hamburg, 3-5 June, ’04 J.Marteau

  2. TT LOW VOLTAGE POWER SUPPLIES • POWER SUPPLIES COST : 2 options can be considered • OPTION A : 1 output () for 4 boards (i.e. per corner) • offers / SM : 72keuros to 110keuros(SCHROFF, M.E.S., CAEN, WIENER) • remark 1 : CAEN offered a special 24% discount which is over now • remark 2 : WIENER could align its price on the one of CAEN • OPTION B : 1 output () for 16 boards (i.e. per TT plane) • ex. WIENER PL6021 F8-12 :6 modules with (+) & (-) outputs, max. 23A/output  1 module/planeremote control & monitoring for each module TCP/IP or CANbus interface6 crates / SM1 air ventilation for 5 crates • 6500euros/crate + 1070euros/fan unit • offer / SM : 39keuros • delivery : 10-12 weeks, prototype available in 4 weeks • meeting in Lyon 08 June with Wiener representatives 2 racks / SM

  3. NETWORK, RACKS & CABLING • OPTION A : • we made the proposal to put small switches in the TTplane corners, which is an economical but risky option (absence of monitoring, long term stability of the small commercial switches…) • cost / SM : 16 keuros • OPTION B : • we have contact with network specialists who advise to replace these small corner switches with more reliable 24&48 ports switches that can be monitored and to take custom bundle cables. • for 1 SM : 12 switches 48 ports, 3 switches 24 ports • CISCO systems : 2295euros & 1191euros (IN2P3 34% discount) • cost / SM (estimate) : 21 keuros (including discount, 32 keuros otherwise)

  4. NETWORK, RACKS & CABLING 1Gbits link 48 48 100 Mbits link Level 0 network 48 48 Level 1 network Admin. network 48 48 VLAN 2 VLAN 1 Public network 48 48 48 48 VLAN 3 VLAN 4 48 48 24 24 192.168.2. 192.168.1. 192.168.3. 192.168.4. adm. adm. adm. T.T. DAQ P.T. DAQ RPC-XPC-VETO VLAN admin. VLAN 0 24 192.168.0. RPC DAQ DB Manager /Admin. P.T. DAQ TT DAQ 2 Internet

  5. NETWORK, RACKS & CABLING :TT low voltage distribution main power supply racks each corner redistributesto 4 electronic boardsafter filtering

  6. NETWORK, RACKS & CABLING :TT Ethernet distribution All the cables(power supplies & ethernet)will run along the end-capsin 1 large & 1 small cable trays The connection « platine »is being designed with theCymantec company.1st prototype ready. We will define the cable lengths etc on Wall 1 mounted in Strasbourg

  7. NETWORK, RACKS & CABLING CONTROL ROOM : • A control room will be located behind the last magnet (2 barracks of 2m*3m on top of each other). • The control room will host DAQ and remote Slow Control & monitoring. RACKS DISTRIBUTION : • RPCs require 16 racks in total. • Magnets require 1 rack for power supplies on each side / SM, to be located in the middle of the magnet, with a total clearance of 1.7m. • PTs require 6 racks in total. It has been agreed that these racks could be located in the middle of the platform (to be checked w.r.t. the temperature).Details about the racks occupancy have to be provided. 1 slot (1U) has to be left for the PT network switch. • TT need 8 racks in total. They are located only on 1 side (wall side). • In total 30 racks are needed and should be available from MACRO (to be checked). • A cable tray of ~0.5m will collect the cables from the back of the racks.GENERAL SKETCH FOR RACKS ORGANIZATION : see next slide.(assuming standard rack dimensions : ~0.6m width, ~1.8m height)

  8. NETWORK, RACKS & CABLING Corridor side Cable tray P.T. racks P.T. racks Cable tray Wall side Spectro.2 Spectro.1 T.T.2 T.T.1 max. 2000 RPC RPC RPC RPC RPC magnet RPC RPC RPC magnet 5000 5575 4340 4340 5000 C.R.2 C.R.1

  9. NETWORK, RACKS & CABLING : RPC crates 27 crates / spectrometer

  10. NETWORK, RACKS & CABLING : RPC racks (odd) 1740mm = 39 U

  11. NETWORK, RACKS & CABLING : RPC racks (even) Switch required close to controllercrates

  12. NETWORK, RACKS & CABLING : TT racks

  13. PT DAQ DEVELOPMENTS DESIGN OF TDC BOARD, including the Ethernet Mezzanine with MSC company (meeting in April).Collaboration of M.Braueur. VME board TDC 1 TDC 2 Selectchip TDC 11 16 bits BUS : signal 6 bits BUS : control TDC 12 • Mezzanine : • readout sequence • zero suppress • trigger timestamps Common STOP RJ45 Clock RJ45 RJ45

  14. PT DAQ DEVELOPMENTS TRIGGER STRATEGY (see also talk by M.Braueur) • Trigger input (common TDC stop) : OR of 2 nearby (X)RPC planes • Trigger rate : around 14 kHz • Data flow : 16 bits / channel 16 * 96 * 14 k = 22 Mbits / s / TDC board (max. 100 Mbits / s) • possible reduction with zero suppress : typically 3 Mbits / s assuming 3 noisy channels per board • still leads to 125 Mbits / s on the PT DAQ PC Being close to the limit, we need the trigger strategy (including XPC & VETO) to be studied in more details (e.g. OR of N1 planes & OR of N2 planes) in terms of rates, efficiencies, hardware setting…

  15. PT DAQ DEVELOPMENTS SLOW CONTROL & MONITORING : • Hardware setup : • HV modules (CAEN SY2527, ethernet CAEN protocol) • crates (CAN bus) • T sensors (CAN bus) • Gas system (dedicated PC)  2-3 PCs to be connected with the DAQ Manager • Software : we agreed to use CORBA for communication with DAQ Manager : • some libraries already exist for these applications • also used by BMM (Brick Manipulator Manager) • M.Braueur start to work on it & to compile the libraries Since most the items (hardware & software) are common to PT & RPC, we shouldoptimize the work & avoid double developments : • combine the purchase of e.g. racks & crates (also for easier maintenance) • adopt the same software environment

  16. CONCLUSIONS (I) • BUDGET : • Update of the DAQ budget performed and submitted to IN2P3 (meeting 09 June) • New procedure for the public markets (January ’04) entering into application now MEZZANINE BOARDS PRODUCTION : • A serious bug has been discovered (and confirmed by AXIS) recently, concerning the RESET input on some MCM chips. This bug is not fixed by AXIS (not even in the upgraded version of the chip) • This requires a new version for the mezzanine (prototype+serie) which prevents us to have the complete TT electronics ready for the 1st 12 walls installation. CAMEROP BOARDS PRODUCTION : • Final version now under tests • 2 Pre-series available (4+36 boards) to be used for tests & calibration • Next serie (this summer) to be installed on the 1st 12 TT walls (mezzanines will be plugged later on the CAMEROP boards : less painful solution to avoid delays).

  17. CONCLUSIONS (II) REQUEST : work could be easier if we could use F/E boards & LED pulsers(when it is possible to pick-up samples from the production batches) RPC MEZZANINES (strongly required) : • dedicated software version (VHDL & CORBA) needs to be developed • a copy of the VME motherboard (+ F/E emulator) has been asked in order to speed up developments and tests PT TDC BOARDS : not on the critical path for the moment. SOFTWARE : • CORBA software is improving constantly (1st versions debugged w.r.t. memoryleaks) • The TTsensor / TTdaq processes defined with omniORB.4.0.3 libraries • Automatic board tests program using the CORBA software • Start the tests with large number of boards connected (equivalent to 1 TT wall).