Sales POV Service Matrix

Source Water. Before utilizing a Living Water Essentials unit, source water identification and testing need to be conducted. Second, is your source water from a private well or a municipality?What is the water pressure? (Dynamic water pressure of seven (7) psi to fifty (50) psi is required.. Min

barclay
Download Presentation

Sales POV Service Matrix

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Sales POV Service Matrix

    2. Source Water Before utilizing a Living Water Essentials unit, source water identification and testing need to be conducted. Second, is your source water from a private well or a municipality? What is the water pressure? (Dynamic water pressure of seven (7) psi to fifty (50) psi is required.

    3. Minimum Requirements The following minimum requirements to utilize a Living Water Essentials device is vital for proper performance. 1. Obtain the TDS Reading 2. Obtain the pH Reading 3. Determine Water Pressure rating (Rating of 7psi to 50 psi) (Water pressure is dynamic)

    4. Conditions Check TDS reading against rating: - 50 – 80 low range for TDS - 81 – 150 mid range for TDS - 151 – 700 high range for TDS - 700 + requires other filtration (not supplied) pH Ratings: Average pH range 6.5 – 8.5 Note: pH ratings below 6.5 or greater than 8.5 will result in the water unit not to function properly

    5. Unit Guidelines: c7 WATER UNIT (c7) based on TDS readings from the water source This unit is programmable based on the TDS reading TDS 50 –80 unit needs to be programmed to a high setting TDS 81 –150 unit is currently set to the mid range setting TDS 151 – 700 unit needs to be programmed to a low setting TDS over 700 require additional filtration is required other than the TR-1 or TR-2 options

    6. Unit Guidelines: p3 WATER UNIT (p3) based on TDS readings from the water source This unit is non-programmable TDS of less than 80 will require the TR-1 with remineralization filter TDS readings over 700 require additional filtration other than the *TR-1 (Above counter single filter) * US40878

    7. Unit Guidelines: u7 WATER UNIT (u7) requires use of the TR-2 system and filters TDS readings over 700 require additional filtration besides the *TR-2 system (Under the counter dual filter system) * US40879

    8. Water Consumption Requirements for all LWE water units (c7, p3 & u7) For drinking purposes the water flow rate is 2 – 2.5 lpm For clean & disinfecting Extremes* the water flow rate is 1.0 lpm for c7 & p3 units and 1.2 lpm for u7 water units Note the extremes come from the drain tube not the flex tube ORP reading –200 to –450 is good drinking water

    9. Water Extremes For high Acidic water use the highest pH setting on the unit, adjust the water flow rate to 1.0 lpm for c7 & p3 units and 1.2 lpm on u7 units then collect the Acidic water from the drain tube For high Alkaline water use the lowest pH setting on the unit, adjust the water flow rate to 1.0 lpm on c7 & p3 units and 1.2 lpm on u7 units then collect the Alkaline water from the drain tube

    10. Troubleshooting Flowchart “A”