CDC Structure. S. Uno KEK 2009.3.18. Endplate Design. sBelle. 350mm. 300mm. 250mm. Wire stringing. Vertical stringing with outer cylinder. Human can stand inside the chamber and can touch the wire. Inner diameter without the small cell part : ~500mm
E N D
CDC Structure S. Uno KEK 2009.3.18
Endplate Design sBelle 350mm 300mm 250mm
Wire stringing • Vertical stringing with outer cylinder. • Human can stand inside the chamber and can touch the wire. • Inner diameter without the small cell part : ~500mm • N. Taniguchi confirmed it with a hand-made mockup. • Stringing with tension can be done from outer layer. • Two-way method ( Belle-CDC ) is not necessary.
CDC structure Shoji Uno (KEK) Dec-3rd, 2008
Baseline Design sBelle Belle
Wire Configuration Present CDC 250 mm 1200 mm New CDC 250 mm
Photo of small cell chamber Just after wire stringing Installation in 2003 summer
Curved Endplate • Deformation of endplate due to wire tension was calculated at design stage of present Belle CDC (Total tension: 3.5 Ton). Deformation(mm) 35.2 2.03 1.31 Present New
Weight • Endplate • Al, Thickness : 10mm (12mm) • 110kgx2 = 220kg (264kg) • Outer Cylinder • CRRP, Thickness : 5mm • 210kg • Electronics Board • G10, 48ch/board • 0.3kgx315 = 95kg
Calculation of deformation and etc • Deformation of Aluminum endplate • Thickness of endplate 10mm 12mm • Deformation 1/t3 1 0.58 • Tension of field wire 120g 80g • Gravitational sag, Sense : 120mm(80g), Field:300mm(80g) • Total tension 4.8ton • Stress calculation • Thickness of outer cylinderCFRP:mm • Transition structure between endplate and outer cylinder • Support structure • Structure for wiring jig • Simpler one as compared with Belle-CDC • Etc.
Wire stringing • Now, I am thinking a vertical stringing, not horizontal. • Once, I thought the horizontal stringing • Vertical stringing with outer cylinder. • Human can stand inside the chamber and can touch the wire. • Inner diameter without the small cell part : ~500mm • Inner diameter of present transition cylinder : 580mm • Stringing with tension can be done from outer layer. • Two-way method ( Belle-CDC ) is not necessary.
Installation • Removing and installation can be done using similar small bar in horizontal direction. Cathode installation in vertical direction CDC installation in horizontal direction