Cosmic Ray Test of GEM-MPI/TPC in Magnetic Field

Cosmic Ray Test of GEM-MPI/TPC in Magnetic Field. Hiroshima University Kuroiwa CDC Group. Mar. 4. 2005. MPGD-Readout TPC. TPC MWPC (Multi Wire Proportional Chamber) readout Two-track separation capability > 1cm MPGD (Micro Pattern Gas Detector) readout GEM , MicroMEGAS

bbrumfield
Download Presentation

Cosmic Ray Test of GEM-MPI/TPC in Magnetic Field

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cosmic Ray Test of GEM-MPI/TPC in Magnetic Field Hiroshima University Kuroiwa CDC Group Mar. 4. 2005

  2. MPGD-Readout TPC • TPC • MWPC (Multi Wire Proportional Chamber)readout • Two-track separation capability > 1cm • MPGD (Micro Pattern Gas Detector) readout • GEM , MicroMEGAS Performance test of GEM-TPC by cosmic ray

  3. GEM as the Readout MPGD • Almost no E×B effects ⇒ good spatial resolution • Fast and spatially narrow induced signals ⇒ good two-track separation • No wire ⇒ thin sector boundaries • Suppression of positive ion feedback

  4. GEM-MPI/TPC • MPI/TPC • Field cage : Maximum drift length = 27cm • Pad plane : 10cm×10cm • Gas : TDR (Ar : CH4 : CO2 = 93 : 5 : 2) • Readout : MWPC ⇒ GEM

  5. GEM-MPI/TPC • GEM • 10cm×10cm • Cu electrodes 5μm thick • Bi-conical holes due to chemical etching (CERN) • 3 GEM plane • VGEM : 320V

  6. 6mm 2mm 0.3mm 0.3mm GEM-MPI/TPC • Pad • Pad plane : 12×64 pads cover 10cm×10cm • Pad size : 2mm×6mm (0.3mm gap) • Readout channels : 7 pad rows×12 pads

  7. Experimental Setup • Setup • Trigger : scintillation counter×3 , 10×27cm • E-field : 300V/cm • B-field : 1T • VGEM : 320V • Gas : TDR

  8. Result • X resolution (Row 1) nominal residual (σn.r.) from track without self info Row 1 has the worst tracking error in all rows geometric mean σ = sqrt(σn.r.・σfull) σfull : from track with self info

  9. Result • X resolution (Row 6) nominal residual tracking error is small in the middle row geometric mean σ shows almost same behavior as the row 1 Effect of large-pad size

  10. Pad Size • Change the pad width Pad width : 2mm Pad width : 1mm produced by the end of March Beam test at KEK-PS in April and June

  11. Summary and Plan • Summary • Geometric mean of row 1 and row 6 show almost same behavior. • Effect of large-pad size • Plan • 1mm pad • Cosmic ray test • Beam test at KEK-PS in April and June • GEM , MicroMEGAS