1 / 34

PG&E Self Generation Incentive Program (SGIP)

PG&E Self Generation Incentive Program (SGIP). August 11, 2009. Call in number: 1-866-234-4460 Meeting number: *4159730770*. Goal & Agenda. Goal Provide general information on the Self Generation Incentive Program and how to apply. Agenda PG&E Background

belenl
Download Presentation

PG&E Self Generation Incentive Program (SGIP)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PG&E Self Generation Incentive Program (SGIP) August 11, 2009 Call in number: 1-866-234-4460 Meeting number: *4159730770*

  2. Goal & Agenda Goal Provide general information on the Self Generation Incentive Program and how to apply Agenda • PG&E Background • SGIP Background, Guidelines, & Eligibility • 2009 SGIP Program & Updates • Wind, Fuel Cell, & Advanced Energy Storage • SGIP Application Process • Quick Tips • Q&A

  3. PG&E Background

  4. PG&E and Our Business What we do: • Deliver safe, reliable, and environmentally responsible gas and electricity to approximately 15 million Californians

  5. PG&E as a Partner and Solutions Provider PG&E Portfolio Solution Reduce Energy Use Partnership Education Outreach Renewable Power Supply ClimateSmart

  6. Integration of EE and PV EE should be implemented prior to PV Why? • EE is typically much more cost-effective than PV • California’s loading order requires that EE be implemented prior to PV • Decreasing a facility’s consumption with EE reduces the size – and cost – of the PV system necessary to offset the facility’s load Inquire about EE before installing PV

  7. 14,000 12,000 10,000 8,000 6,000 4,000 2,000 California United States 0 2004 2006 2008 2002 1978 1980 1982 1984 1986 1988 1990 1992 1994 1996 1976 1998 2000 1960 1962 1964 1966 1968 1970 1972 1974 We’re Committed to Energy Efficiency Over the past 30 years, California per capita energy use has remained relatively flat compared to the 50% increase in U.S. per capita energy use. Source: California Energy Commission

  8. SGIP Background, Guidelines, & Eligibility

  9. SGIP Background: Program Summary • California Public Utilities Commission (CPUC) rebate program initiated in 2001 to reduce peak demand on the grid • Scheduled to continue accepting applications through 2012 • Provides incentives for the installation of new, qualifying self-generation equipment installed to meet all or a portion of the electric energy needs of a facility (Large Wind, Fuel Cell, and Advanced Energy Storage Systems) • Program Administrators: 1. Pacific Gas & Electric Company (PG&E)2. Southern California Edision (SCE)3. Southern California Gas (SoCal Gas)4. California Center for Sustainable Energy (CCSE) for San Diego Gas & Electric (SDG&E)

  10. SGIP Background: Eligible SGIP Technologies 2001-2005 • Level 1: PV, Wind, Renewable Fuel Cells • Level 2: Non-Renewable Fuel Cells • Level 3N, 3R: Microturbines, IC Engines, Small Gas Turbines 2006 • Level 1: PV • Level 2: Renewable Non-Solar: Fuel Cells, Microturbines, IC Engines, Small Gas Turbines, & Wind • Level 3: Non-Renewable Non-Solar: Fuel Cells, Microturbines, IC Engines, Small Gas Turbines 2007 • Level 1: PV transitioned into California Solar Initiative (CSI) Program • Level 2: Renewable Non-Solar: Fuel Cells, Microturbines, IC Engines, Small Gas Turbines, & Wind • Level 3: Non-Renewable Non-Solar: Fuel Cells, Microturbines, IC Engines, Small Gas Turbines

  11. SGIP Background: Eligible SGIP Technologies (Cont.) 2008 • Level 2: Renewable Non-Solar: Fuel Cells, Wind • Level 3: Non-Renewable Non-Solar: Fuel Cells, Microturbines, IC Engines, Small Gas Turbines 2009: • Level 2: Renewable Non-Solar: Fuel Cells, Wind • Level 3: Non-Renewable Non-Solar: Fuel Cells, Microturbines, IC Engines, Small Gas Turbines • Level 2 or Level 3: Advanced Energy Storage, Coupled with a new or existing SGIP funded Wind or Fuel Cell

  12. SGIP Guidelines & Eligibility Eligible customer projects must be within the service territory of and must receive retail level electric and/or gas service from: • Pacific Gas and Electric (PG&E) • Southern California Edison (SCE) • Southern California Gas Company (SoCal Gas) • San Diego Gas & Electric (SDG&E) • The California Center for Sustainable Energy (CCSE) administers the SGIP in the SDG&E Service Territory

  13. SGIP Guidelines & Eligibility (Cont.) • Maximum incentive is 3 MW, with maximum system size 5 MW1 • Must be interconnected and serve on-site load • Non-Renewable systems must satisfy PU Code 216.6 requirements or documenting a minimum electric efficiency equal to or greater than 40% of higher heating value basis • All fossil fuel combustion generators must satisfy both a 60% overall system efficiency and a NOx emissions equal or less than .07 lbs/MWh 1 Per Decision (D.) 08-04-049, SGIP Administrators for 2008 and 2009, on a pilot basis, will pay qualifying distributed generation projects incentives up to 3 megawatts (MW) from prior years’ carryover funds

  14. 2009 SGIP Program & Updates

  15. 2009 Program Updates • California Supplier - An additional incentive of 20 percent will be provided for the installation of eligible distributed generation technologies from a California Supplier. (Section 3.5) • AES - Advanced Energy Storage systems that meet certain technical parameters and are coupled with eligible SGIP technologies, currently wind and fuel cell technologies, are eligible in PY2009 and will receive an incentive of $2 per watt of installed capacity. • The PY2009 budgets by SGIP Program Administrator are –

  16. 2009 SGIP Incentive Rates For projects that are greater than 1 MW up to 3 MW, the incentives identified above declines according to the schedule below:

  17. 2009 PG&E Program Goals • Encourage and facilitate more DG systems • Reduce Barriers • SGIP Application Requirements • Interconnection Paperwork • Expand Marketing & Outreach Efforts • Possible partnerships with Developers and State • Educate Community about DG systems and SGIP Program • Webinars, Classes, Expos, Conventions

  18. Wind, Fuel Cells, and Advanced Energy Storage

  19. Wind Requirements • Wind turbine rated capacity is the highest electrical output from the manufacturer’s power output curve for wind speeds up to 30 mph including inverter losses. (Section 2.5.4) • Wind Turbine Projects may be sized up to 200% of the Host Customer’s previous 12-month annual peak demand at the proposed Site. (Section 2.5.6.1) • Equipment: Inverter must be on CEC Approved List, Wind Turbines must be commercially available • System Size: > 30 kW, < 30 kW applies through CEC Emerging Renewable Program • 5-year system warranty

  20. Fuel Cell Requirements • Renewable Fuel Cell vs. Non-Renewable Fuel Cell • Renewable Fuel: Biogas, Landfill Gas, Digester Gas • Non-renewable Fuel: Natural Gas, Waste Gas • To qualify as a renewable fuel cell, fuel source must be > 75% renewable • Non-Renewable Fuel cells must meet a minimum 40% operating efficiency requirement • Fuel Cell Projects may be sized up to 100% of the Host Customer’s previous 12-month annual peak demand at the proposed Site. • Equipment: Fuel Cell Equipment must be commercially available • System Size: Capped at 5 MW with incentives up to 3 MW • 5-year system warranty

  21. Fuel Cells – Typical Applications

  22. AES Background What is AES? AES stands for Advanced Energy Storage. These are battery-like storage systems that convert energy to a storage medium and then reconvert back to energy. Timeline • December 2006 - VRB submitted a request to include AES as an eligible technology in the SGIP • July 2007 – SGIP Working Group delivered split recommendation to CPUC for deliberation • Summer 2008 – CPUC conducted additional fact finding through the proceeding. • November 2008 – CPUC approved introduction of AES

  23. AES Requirements • AES is to be coupled with a current SGIP technology. It is required that incentives be funded from the same budget as the accompanying technology. • Any current or previously funded SGIP projects (Wind or Fuel Cells) is eligible to install AES and receive incentives. • AES must be sized no larger than the rated capacity (kW) of the SGIP eligible technology it is operating in concert with. • The Advanced Energy Storage Project capacity rating must be the net continuous discharge power output (kW) over a four hour period and must be established from manufacturer documentation.

  24. AES Requirements (Cont.) • Advanced Energy Storage systems utilizing hydrogen as the storage medium are not eligible at this time. (Section 2.5 and Section 6). • Ability to meet IEEE Interconnection standards • Ability to operate in distributed, customer sited locations and comply with all local environmental and air quality requirements • 5-year system warranty consistent with other eligible program technologies

  25. SGIP Application Process

  26. SGIP Application Process Overview Applicant Program Administrator

  27. SGIP Application Process – Step 1 of 4 Reservation Request Form (RRF) • Reservation Request Application Form & Checklist • Proof of Utility Service • 12-month Electric Load Documentation • Proof of Adequate Renewable Fuel Source (Renewable Fuel Cell Only) • Waste Heat Emission Worksheet (Non-Renewable Fuel Cell Only) • Application Fee – 1% of requested incentive • For equipment that is not commercially available

  28. SGIP Application Process – Step 2 of 4 Proof of Project Milestone (PPM) • Proof of Project Milestone Checklist • Copy of Executed Installation Contract • Revised Minimum Operating Efficiency Calculations (Non-Renewable Fuel Cells, if applicable) • Fuel Clean-Up Equipment Purchase Order (Renewable Fuel Cells Only) • Renewable Fuel Affidavit (Renewable Fuel Cells Only)

  29. SGIP Application Process – Step 3 of 4 Incentive Claim Form (ICF) • Incentive Claim Form & Checklist • Proof of Authorization to Interconnect • Final Project Cost Breakdown Worksheet • Final Project Cost Affidavit • Final Building Permit Inspection Report • Substantiation of load (if applicable) • Substantiation of Renewable Fuel Source (Renewable Fuel Cells Only) • Revised Sizing Calculations (if applicable) • Revised Minimum Operating Efficiency Calculations (Non-Renewable Fuel Cells, if applicable) • Final Fuel Clean-up Skid Documentation (Renewable Fuel Cells only) • Final Air Permit Documentation (Non-Renewable/Renewable Fuel Cells Only)

  30. SGIP Application Process – Step 4 of 4 Field Inspection • Required for all SGIP projects • Verify Make, Model, and System Sizing of Equipment Installed • Verify Load Substantiation for project • Verify Fuel Source • Confirm Permanency of Installation

  31. Net Energy Metering Options • NEM Wind (NEMW) • Full retail credits < 50 kW systems • Generation credits only > 50 kW systems • NEM Fuel Cells (NEMFC) • Generation credits only • NEM Biogas (NEMBIO) • Generation credits only • Dairies can apply generation credits to other accounts • NEM Multiple Technologies (NEMMT) • For meters with hybrid technologies or • NEM and Non-NEM interconnection • NEM limited to 1 MW per meter • Rule 21 Non-Export • Generators that will never export • Simpler billing for customers

  32. Quick Tips • Perform EE audit and implement measures • No Cost • Low Cost • Investment • Contact PV consultants or vendors • Solicit bids from multiple vendors • Evaluate proposals using standardized criteria • Inspect PV system periodically

  33. SGIP Resources SGIP Contact Information • SGIP Hotline: (415) 973-6436 • SGIP Inbox: selfgen@pge.com • Website: www.pge.com/sgip Interconnection Contact Information • Interconnection Hotline: (415) 972-5676 • Interconnection Inbox: gen@pge.com • Website: www.pge.com/gen

  34. Q&A Questions?

More Related