1 / 35

Engineered Products Make-Up Air for Heating and Cooling

Engineered Products Make-Up Air for Heating and Cooling. MAKE-UP AIR. Why do we need make up air?. EXHAUST AIR. KITCHEN HOODS MANUFACTURING APPLICATIONS PAINT BOOTHS PROCESS AIR. BUILDING PRESSURIZATION. CORRIDOR PRESSURIZATION FIRE CONTROL KEEPS ODORS IN APARTMENTS, ETC .

benito
Download Presentation

Engineered Products Make-Up Air for Heating and Cooling

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Engineered ProductsMake-Up Air for Heating and Cooling

  2. MAKE-UP AIR Why do we need make up air?

  3. EXHAUST AIR • KITCHEN HOODS • MANUFACTURING APPLICATIONS • PAINT BOOTHS • PROCESS AIR

  4. BUILDING PRESSURIZATION • CORRIDOR PRESSURIZATION • FIRE CONTROL • KEEPS ODORS IN APARTMENTS, ETC. • BUILDING PRESSURIZATION • REDUCES OUTSIDE AIR INFILTRATION

  5. BUILDING VENTILATION • BUILDING VENTILATION • CONSTANT VOLUME • INTERMITTENT VOLUME

  6. Key Audience • Many Restaurants, Apartment Complexes and Factory Upgrades are done through Design Build Projects • Owner and installing contract size the equipment themselves without the use of an engineer • Schools, Government Buildings, Concert Halls and New Factories are done through Plan & Spec Projects • Engineers are typically used to layout equipment sizes

  7. HOW CAN TRANE HELP?? • Trane Offers a Complete Line of Outdoor and Indoor HVAC Equipment to Satisfy Your Make-Up Air Needs.

  8. Outdoor UnitsUnit Types • Model “GR” Option “G”– Gravity Vented Outdoor • Model “GR” Option “P”– Power Vented Outdoor

  9. Indoor UnitsUnit Types • Model “GG” – Power Vented Indoor

  10. Indoor UnitsUnit Types • Model “GX” – Separated Combustion Indoor

  11. Indoor/Outdoor UnitsUnit Types • Model “AH” Air Handler

  12. Arrangements • Consists of Individual Pre-Engineered Modules Arranged to Address Your Individual Applications

  13. Furnace Construction Material • Duct Furnace Heat Exchangers are Available in 3 Types of Steel • Stainless Steel Packages: Provides a Total Package Protection by Including 409 SS Burners and Flue Collector • Aluminized Steel • 409 Stainless Steel • 321 Stainless Steel

  14. GAS CONTROL • A Full Range of Gas Controls, Including: • Single Stage • Two Stage • Electronic Modulation • Room Sensing • Duct Sensing (W/, W/O Rm. O/R) • Others, Including 4-20 mA & 0-10 VDC Controls and Multi-Furnace Staging

  15. Coil Options • Factory Installed Coils • Direct Expansion (DX) • Chilled Water • Steam • Hot water • Draw Through Design Maximizes Coil Efficiencies • Full Size ASHRAE 62 Compliant Drain Pan • 4 Row & 6 Row, Single or Dual Circuit • Cooling Coil 1,000-6,300 CFM Range* • 3-30 Tons, But There is Flexibility. When in Doubt, Call!

  16. Indoor/Outdoor UnitsUnit Types • Evaporative Cooler Section

  17. Features and Benefits • ETL Certified • 18 Gauge Cabinets Painted Trane Grey • 20 Gauge Aluminized Steel Heat Exchangers • Single Stage Redundant Gas Valve • Low internal static pressures allow for smaller motor break horse power requirements

  18. Features and Benefits • Standard Left Hand Access, Right Hand Optional • Multiple Gas and Air Control Options • 1” Matte Face Insulation

  19. Features and Benefits • Ship Loose Parts List

  20. Features and Benefits 1 2 8 3 9 4 10 5 11 6 12 13 7

  21. Motor Types • Open Drip Proof (ODP) • Premium Efficiency (PEODP) • Totally Enclosed (TE) • Premium Efficiency (PETE)

  22. Air Inlet Configuration • Indicates • Use of Outside and / or Return Air • Use of an Air Hood (Shipped Separately)

  23. Factory Installed Options • Low Leak Damper • 409 SS Furnace Drip Pan • High Altitude Derate • Input Derate • Evaporative Cooler • 12” CELdek® Media • 8” & 12“ GLASdek ® Media • Clogged Filter Switch • Manual Blower Switch • Firestat (Supply and / or Return) • Freezestat (Time Delayed) • Ambient Lockout • Interlock Relays (Specify Purpose) • Moisture Eliminators • Horizontal Return • Status Lamps • Double Wall Construction • Service Convenience Package • High / Low Gas Pressure Switch • Filters (TA, WA & Pleated) • Through the Base Utility Penetrations

  24. Field Installed Accessories • High Pressure Regulators • Time Clocks • GFI Convenience Outlet • Thermostats • DuctStats • Disconnect Switches • Evaporative Cooler • Fill & Drain Kit • Freezestat • Remote Control Panel

  25. Competitive ProductModine Make Up Air • DFP/DBP/DCP – Indoor Unit • DFS/DBS – Indoor Separated Combustion Unit • DCS w/ Cooling • WeatherHawk Series • HFG, HFP, HBG, HDG, HPG

  26. Competitive ProductModine Make Up Air • All Model Types Start @ 75 MBH and Go to 1,200 MBH • HFG/P 75-400 • CFM Range 550 – 14,800 • Temperature Rise – 20 – 120 F. • 80% Thermal Efficiency • Maximum External Static Pressure 3” W.C. • Available w/ DX or Chilled Water Options • CFM Range 762 – 5,200 • Available on Sizes 75-400

  27. Competitive Product Modine Make Up Air • ETL Certified On Entire Unit • 18 Gauge Aluminized Blower Cabinet • 20 Gauge Clamshell Heat Exchanger • 409 SS Optional • Double Wall Construction on Blower and/or Cooling Cabinet (Option) • Full Range of Air & Gas Controls Available • Equal to Trane Offering • Baked-on Polyester Powder Paint

  28. Competitive ProductReznor Make-Up Air • RPB(L)/RDH Outdoor Power Vented M/U Air Unit • Gravity Vented Unit (RGB) No Longer Available • RPB(L)/HRP/RPV/HRPV • PDH/PGBL • Indoor M/U Air • SDH/SSCBL • Indoor Separated Combustion M/U Air • “L” = Long (400 – 1200 MBH)

  29. Competitive ProductReznor Make-Up Air • Size Ranges From 75 MBH – 1200 MBH • CFM Range 475-14,000 Outdoor Units • CFM Range 560 – 139,000 Indoor Units • Temperature Rise 40-120 F. • 80% Thermal Efficient • “PreevA” Products (PDH & SDH) Minimum 81% • All Products Power Vented as Standard

  30. Competitive ProductReznor Make-Up Air • ETL Certified On Entire Unit • Aluminized Heat Exchangers as Standard • 409 S/S Available – Heat Exchangers, Burners, Drip Pan • 316 S/S Available Heat Exchanger Only • Double wall • Pre-coat RAL 9001 white paint finish • Wide Range of Control Options • Mechanical Modulation Available • Electronic Modulation Available Down to 20%-100% Turndown

  31. What Next? • These are the project we are working on in the immediate future. • We have many more projects planned for when these are completed.

  32. Variable Frequency Drive • SM Vector Line • NEMA 1 Enclosures • Plenum Rated • Operating Range • 14oF Minimum • 130oF Maximum • Two Year Warranty

  33. Seismic and Vibration Isolation Curbs

  34. Energy Recovery Module

  35. X1 – 90+% Efficient Rooftop Unit

More Related