1 / 13

Phantom Simulation of Liver Motion During Breathing

Phantom Simulation of Liver Motion During Breathing. Group Members: Ian Dallmeyer Tuta Guerra Ian Henderlong Advisor: Dr. Bob Galloway. Background. Over 225,000 people in the U.S. diagnosed with primary or metastatic liver cancer in 2003. Cancers often spread throughout the liver.

bernad
Download Presentation

Phantom Simulation of Liver Motion During Breathing

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Phantom Simulation of Liver Motion During Breathing Group Members: Ian Dallmeyer Tuta Guerra Ian Henderlong Advisor: Dr. Bob Galloway

  2. Background • Over 225,000 people in the U.S. diagnosed with primary or metastatic liver cancer in 2003. • Cancers often spread throughout the liver. • Traditional surgery difficult/not possible. • No IGS techniques for the abdomen. • Respiratory motion • Pigs • Liver structure different than humans.

  3. Problem • Need an anatomically correct model which accurately simulates liver motion due to breathing to test IGLS techniques.

  4. Advantages of Phantom Model • Porcine Liver • Approx. $1,000 – $2,000 per liver • Not anatomically correct • Not reusable • Phantom model • Anatomically correct • Reusable • Time and space-saving

  5. Alternatives to Modeling Liver Motion • High-Frequency Jet Ventilation • Disadvantages • Maximum Duration of 45 min. • Cardiovascular Complications • Patient Response • Expensive

  6. Market Potential • Current methods too invasive • Open liver resection • Estimated market for IGLS 10x current IGNS market • IGLS: $3.0-$7.5 billion • Reusable model needed to perfect IGLS techniques

  7. Phantom Liver System Design

  8. Shape Memory Alloy • Shape memory alloys deform upon heating • Martensite – low T, soft, deformable • Austenite – higher T, hard, non-deformable • Other SMA’s - CuZnAl, and CuAlNi

  9. Alternatives to Modeling Liver Motion • Linear Actuators • Many Different Types • Cost Increases with Resolution • Linear Actuators with required specs cost $150 • http://nanotech.com

  10. Design Specs • 1-D Linear motion (cranial- caudal) • 10.8 + 2.5 mm (ATLM) • Breath Frequency ~= .11 Hz. (1 breath/9 sec)

  11. Current Work • Force determination • Finalize acquisition of materials • Test cart and recoil system

  12. Future Work • Construction of power source • Assemble phantom liver sytem in PVC pipe

  13. References • Herline AJ, Stefansic JD, Debelak JP, Hartmann SL, Wright Pinson C, Galloway RL, Chapman WC. Image Guided Surgery: Preliminary; Feasibility Studies of Frameless Stereotactic Liver Surgery. June 1999 Archives of Surgery 134:644-650 • Tarczy-Hornoch P, Jones D, Zerom B, Woodrum D, and Berk R. Mechanical Ventilators. [Online] Available http://weber.u.washington.edu/~neonatal/NICU-WEB/vents.html, 1998.

More Related