Importance of an Automatic Transfer Switch

Automatic transfer switches come in a variety of designs, but typically a mains failure relay is fitted in an electrical enclosure, with two contactors.

Download Presentation

Importance of an Automatic Transfer Switch

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Blades Power Generation Ltd Importance of an Automatic Transfer Switch If you have a standby generator at your home so that you can still generate electricity when the power fails, then the law requires you to have a transfer switch. This is the case in every country when installing a generator at a property with a mains supply. It can either be a manual transfer switch in the UK or an automatic transfer switch. It doesn’t matter which, but you must have one or the other.

  2. Blades Power Generation Ltd Somebody Needs To Be On The Premises Not only that, but it also means that somebody needs to be on the premises at the time the mains goes down. In some instances, this may not be much of a problem, but could cause issues if you need a constant supply of power. With an automatic transfer panel, the generator will start up automatically whether you are there or not. Automatic transfer switches come in a variety of designs, but typically a mains failure relay is fitted in an electrical enclosure, with two contactors. These are electrically and mechanically interlocked so that they cannot both be closed at the same time. The contactors need electric power in order to close.

  3. Blades Power Generation Ltd The mechanical interlock should stop both contactors closing at the same time, but the electrical interlock provides extra protection. A normally closed contact is fitted to each contactor and when the contactor is energised, they open. If you have two contactors, A and B, the circuit to close contactor A is wired through the auxiliary of B. Therefore, when B is closed, it is not possible to energize A. The same is true for B, which is wired through the auxiliary of A. This provides the electrical interlock.

  4. Blades Power Generation Ltd What happens is that when the mains fails, the ATS will send a signal to the generator and when it is up to full power the ATS will open the mains contactor and close the generator contactor. When the mains returns, the generator contactor is opened and the mains contactor is closed. This means that there will always be a short break in the power supply when changing over.

  5. Blades Power Generation Ltd Contact us Address: Devereaux Cres, Ebley, Stroud GL5 4PX Landline: 01453 799655 Email: sales@bladespowergeneration.com Website: https://www.bladespowergeneration.co.uk/