Building Codes and Design Requirements for Specialty Shops, Restaurant, and Cocktail Lounge

Learn about the building codes and design requirements for specialty shops, restaurants, and cocktail lounges. Find out the specifications for corridor and aisle widths, door widths, protruding objects, and elevated dining ramps.

blanc
Download Presentation

Building Codes and Design Requirements for Specialty Shops, Restaurant, and Cocktail Lounge

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Liz Day Aya Nishio Katie Burnett Latrina Hughes Margaret Emery Martin Spurgeon Team 2

  2. We were responsible for: • Specialty Shops • Restaurant • Cocktail Lounge

  3. 1. What code publications are adapted and what year do they use? Louisiana Codes • Building/Dwelling code IBC 2006 excluding Ch 1, 11, 27, 29 • Structural code IBC 2006 excluding Ch 1, 11, 27, 29 • Plumbing Code La State Plumbing Code 2000 • Mechanical Code Mechanical Code 2006 • Electric Code National Fire Code (NFC) 2005 • Fire/Life Safety Code National Fire Protection Agency (NFPA) • Accessibility Code ADA Accessibility Guidelines (ADAAG) • Energy Code ASHRAE (90.1) 2001 • Gas Code International Fuel Gas Code (IFGC) 2006 • Boiler Code American Society of Mechanical Engineers (ASME) Boiler Pressure Vessel Code 1995 w/1998 Addendum margaret

  4. 2. Summary of Building Codes/ADA/Life Safety Codes for your spaces.

  5. 2a. Corridor and aisle widths, door widths, protruding objects, elevated dining aya

  6. Corridor And Aisle Widths Corridor width Typical - 44” Occupancy Load < 50 - 36” minimum or 2” x Occupancy Load - sprinklered 0.15 x Occupancy Load - unsprinklered *Apply the larger one • Aisle width • Typical – 36” • Or • 0.2” x Occupancy Load - sprinklered • x Occupancy Load – unsprinklered • *Apply the larger one aya

  7. Door Widths Door width 32” minimum clear width Or 0.2” x O.L. - sprinklered 0.15 x O.L - unsprinklered aya

  8. Protruding Objects Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in above the finished floor shall protrude no more than 4 in into walks, halls, corridors, passageways, or aisles (see Fig. A. Objects mounted with their leading edges at or below 27 in above the finished floor may protrude any amount (see Fig. 1-A and B). aya

  9. Protruding Objects Free-standing objects mounted on posts or pylons may overhang 12 in maximum from 27 in to 80 in above the ground or finished floor. aya

  10. Protruding Objects Protruding objects shall not reduce the clear width of an accessible route or maneuvering space. aya

  11. Protruding Objects (Handrails) If a ramp run has a rise greater than 6 in or a horizontal projection greater than 72 in then it shall have handrails on both sides. Handrails are not required on curb ramps or adjacent to seating in assembly areas. The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 in to 1-1/2 in or the shape shall provide an equivalent gripping surface. If handrails or grab bars are mounted adjacent to a wall, the space between the wall and the grab bar shall be 1-1/2 in. (Fig. 4) Handrails may be located in a recess if the recess is a maximum of 3 in deep and extends at least 18 in above the top of the rail. aya

  12. Protruding Objects • Handrails shall have the following features: • Handrails shall be provided along both sides of ramp segments. The inside handrail on switchback or dogleg ramps shall always be continuous. • If handrails are not continuous, they shall extend at least 12 in beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface. (Fig.5) • The clear space between the handrail and the wall shall be 1 - 1/2 in. • Gripping surfaces shall be continuous. • Top of handrail gripping surfaces shall be mounted between 34 in and 38 in above ramp surfaces. • Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post. • Handrails shall not rotate within their fittings. aya

  13. Elevated Dining Ramp Requirements for Elevated Dining (Ramp Width) The least possible slope shall be used for any ramp. The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (see Fig. 20) aya

  14. Elevated Dining Fig. 2 **Curb ramps and interior or exterior ramps to be constructed on sites or in existing buildings or facilities where space limitations prohibit the use of a 1:12 slope or less may have slopes and rises as follows: (i) A slope between 1:10 and 1:12 is allowed for a maximum rise of 6 inches. (ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed. (Minimum Clearance) The minimum clear width of a ramp shall be 36 in (minimum requirement in ADA) however when it is used as a component of the means of egress, it shall be 44in (required by Life Safety Code). aya

  15. Elevated Dining (Landings) Ramps shall have level landings at bottom and top of each ramp and each ramp run. Landings shall have the following features: (1) The landing shall be at least as wide as the ramp run leading to it. (2) The landing length shall be a minimum of 60 in clear. (3) If ramps change direction at landings, the minimum landing size shall be 60 in by 60 in. (4) If a doorway is located at a landing, then the area in front of the doorway shall comply with ADA 4.3.16 (Fig.3) aya

  16. Elevated Dining Landings aya

  17. 2b. Egress door locations (half-diagonal rule) • All commercial doors are suppose to open in the direction of the fire exit route • ½ diagonal rule is that your fire exits should be no more then ½ of the room if walking. • Square foot 100’ • ½ of room is 50’ • So you should have at least 50’ between the two fire exits. margaret

  18. 2c. Dead end corridors Dead-end corridors can extend 50 ft. in a building with quick responsesprinklers.  A non-sprinkled building cannot have a dead-end corridor extending beyond 20 ft. unless the width of the hallway is less than 2.5 times the least width of the dead-end corridor. katie

  19. 2d. Fire classification for flooring, walls and ceiling finishes • A hotel with restaurant, ballrooms, or workout rooms is considered to be Assembly or Business. • Information from chart on page 370: Fire classification for Restaurant, Specialty Shops, and Cocktail Lounge is: for Assembly less than or equal to 300- trina

  20. 2e. Table spacing, aisles, etc. in restaurants • Table Spacing • (pg 342, fig 2) • square spacing – 60” apart • Diagonal Spacing 30” • Aisles • Aisles – (page 346, silver book) 3’ wide • Passage ways - 2’ wide martin

  21. 2f. Fire standards for fabrics "Flammability Fabrics Act". 16CFR30-33 is about interior finishing materials. aya

  22. Other (i.e.: signage, booth details Pictures added to words help non English speaking people Height of signs and considering people who are blind and read Braille martin

  23. 3. Find photos or illustrations of the following to share in your PowerPoint:

  24. 3a. Furniture style, placement, finishes (booths, chairs, tables) list hospitality manufacturers and websites • Manufacturers • http://www.andythorntonusa.com/ • http://www.modernrugs.com/ • http://inlandmfg.com/ • http://www.resources.com/ • http://contractfurniture.com/ • http://www.hotelmanagement-network.com/ martin

  25. 3b. Flooring type, pattern, texture, manufacturers. katie

  26. FLOORING http://www.architecturalceramics.net http://www.pulsarlight.com http://www.armstrong.com http://www.millikencarpet.com http://www.shawfloors.com Floor & Pattern Continued katie

  27. 3c. Wall covering, pattern, scale katie

  28. www.omnova.comwww.bigapplewallcovering.com3FORM.COMWWW.CUSTOMCOLOR.COMhttp://www.conceptcoverings.co.uk/www.metrowallcoverings.comwww.omnova.comwww.bigapplewallcovering.com3FORM.COMWWW.CUSTOMCOLOR.COMhttp://www.conceptcoverings.co.uk/www.metrowallcoverings.com Wall covering, pattern, scale cont. katie

  29. 3d. Lighting, scale, style, placement, manufacturer katie

  30. Lighting, scale, style, placement, manufacturer cont. katie

  31. 3e. Fixtures, wait stations, cashier station margaret

  32. 3f. Maitre d’ station (hostess station) trina

  33. 3g. What finishes are used on counters, table tops, table bases Lobby counters are usually marble or granite in higher end hotels

  34. Table Tops & Bases Five star hotel restaurants usually have table cloths and the bases could be of any material such as metal or wood. martin

  35. 3h. Store fixtures, manufacturersRetail Design Award Aya

  36. Retail Design Award Fixture of the Year 2004 Fixture of the Year 2004 Futuretronics: Display Pod Grouping Location: Mall of Millenia, Orlando, Fl Fixtures by: Moz Designs, Oakland, CA http://www.mozdesigns.com/index.html With the glass pod vitrine display fixtures serving as the graphic identity of high-en electronics store. The fixtures feature flexible display shelves projecting from clear acrylic poles that extend out of a glowing resin base, all within a 10-ft.-tall glass enclosure. Aya

  37. Retail Design Award Fixture of the Year 2005 Fixture of the year 2005 Cartier: Fixture Grouping Location: Honolulu, Hawaii Fixtures by: Cassina S.P.A., Milan, Italy http://www.cassina.com/ Molteni & Co., Giussano, Italy http://www.molteni.it/ This group of freestanding showcases is an ideal fit for the fine jewelry and watches. The traditional design elements with a contemporary spin offer the flexibility to display items according to client tendencies Aya

  38. Retail Design Award Fixture of the Year 2006 Fixture of the Year 2006 Oliver Peoples: Full Store Fixture Grouping Location: Crystal Court, Santa Ana, Calif. Fixtures by: Moon Design Manufacturing, Vista, CA http://www.moondesignmfg.com/ Self-illuminated fixtures draw all eyes to the products. The wall displays also contain drawers for product storage, and a flat-screen monitor integrated into the framework plays classic Hollywood movies referencing fashion and excitement. Aya

  39. Retail Design Award Fixture of the Year 2007 Fixture of the Year 2007 Lily Simon: Fixture Grouping Location: Centre Rockland, Montreal Fixtures by: Les Matrices Carritec, Dorval, PQ, Canada http://www.carritec.com/ Vitre Tout Inc., Montreal, PQ, Canada http://www.vitretout.com/ Boisdaction Inc., Princeville, PQ, Canada Contrasting with a neutral background, a 2-ft.-6-in.-wide ebony table featuring seasonal high-end fashion wear meanders up the steps and cuts across the vast space. Against the curved back wall, straight bar racks maintain the openness of the area by spacing merchandise apart. Aya

  40. Artwork and Accessories 3i. Artwork and accessories Harmonic Environments http://www.harmonicenvironments.com/ Custom Cascade Water with lighting solution for commercial interior design. Counterbalance Sculpture http://www.counterbalancesculpture.com/ Sculpture pieces by a ceramic artist, Brian Mackin offer clean and simple form inspired by Mid-century Modern architecture. Aya

  41. Artwork and Accessories – cont. Boyd Lighting http://www.boydlighting.com/ A lighting manufacturer that creates contemporary decorative fixtures for commercial interiors using ancient Southern American hand craft technique. Magnuson Group http://www.magnusongroup.com/ A contemporary contract furniture manufacturer with variety of products including interior accessories. (Left: Umbrella Stand, Middle: Ashtrays, Right: Merchandising Display) Aya

  42. Artwork and Accessories –cont. Aswoon - Susan Woods Studio http://www.aswoon.com/ An art studio specializes in the design and fabrication of high-end objects d'art and architectural additions in a variety of sophisticated and reclaimed materials. Orit Zeidman,  Ambient Art. http://www.oz-arts.com/ An art studio owned by a painter Orit Zeidman, who enjoys rave reviews, introduces a new and revolutionary concept in original fine art with a customized, original, one of a kind painting, created specifically for the customer's space. Aya

  43. 3j. Examples of display windows/store fronts for specialty shops trina

  44. 3k. Restaurant entrances from street liz

  45. 3l. Double door entrances from kitchen to dining area liz

  46. 3m. Bar designs, finishes used, furniture and manufacturers liz

  47. Finishes metal wood liz

  48. Furniture liz

  49. Furniture liz

  50. Furniture Accessories liz