1 / 9

ATLAS Wire Tension Measurement system

ATLAS Wire Tension Measurement system. ATLAS Wire Tension Measurement system. The system uses electrostatic force to excite mechanical oscillation around the wire fundamental harmonic resonance The oscillation amplitude is sensed by measuring the capacitance variation in the wire-tube system

bo-mejia
Download Presentation

ATLAS Wire Tension Measurement system

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ATLAS Wire Tension Measurement system

  2. ATLAS Wire Tension Measurement system • The system uses electrostatic force to excite mechanical oscillation around the wire fundamental harmonic resonance • The oscillation amplitude is sensed by measuring the capacitance variation in the wire-tube system • Changing the high voltage modulation frequency  mechanical resonance curve • Fully operated by a PC LabVIEW program

  3. ATLAS Wire Tension Measurement system Measure = fout(HV OFF) – fout(HV ON) HV ON HV OFF

  4. ATLAS Wire Tension Measurement system WTM internal view

  5. ATLAS Wire Tension Measurement system Sensor and HV modulation connections RS 232 and T sensor connections

  6. ATLAS Wire Tension Measurement system Control panel WTM

  7. Parameter setting section ATLAS Wire Tension Measurement system

  8. ATLAS Wire Tension Measurement system section Output

  9. ATLAS Wire Tension Measurement system